  1. Al-Makramani BM, Razak AA, Abu-Hassan MI
    J Appl Oral Sci, 2010 Dec;18(6):607-12.
    PMID: 21308292
    Advances in all-ceramic systems have established predictable means of providing metal-free aesthetic and biocompatible materials. These materials must have sufficient strength to be a practical treatment alternative for the fabrication of crowns and fixed partial dentures.

    OBJECTIVES: The aim of this study was to compare the biaxial flexural strength of three core ceramic materials.

    MATERIAL AND METHODS: Three groups of 10 disc-shaped specimens (16 mm diameter x 1.2 mm thickness - in accordance with ISO-6872, 1995) were made from the following ceramic materials: Turkom-Cera Fused Alumina [(Turkom-Ceramic (M) Sdn Bhd, Puchong, Selangor, Malaysia)], In-Ceram (Vita Zahnfabrik, Bad Säckingen, Baden-Württemberg, Germany) and Vitadur-N (Vita Zahnfabrik, Bad Säckingen, Baden-Württemberg, Germany), which were sintered according to the manufacturer's recommendations. The specimens were subjected to biaxial flexural strength test in an universal testing machine at a crosshead speed of 0.5 mm/min. The definitive fracture load was recorded for each specimen and the biaxial flexural strength was calculated from an equation in accordance with ISO-6872.

    RESULTS: The mean biaxial flexural strength values were: Turkom-Cera: 506.8 ± 87.01 MPa, In-Ceram: 347.4 ± 28.83 MPa and Vitadur-N: 128.7 ± 12.72 MPa. The results were analyzed by the Levene's test and Dunnett's T3 post-hoc test (SPSS software V11.5.0 for Windows, SPSS, Chicago, IL, USA ) at a preset significance level of 5% because of unequal group variances (P<0.001). There was statistically significant difference between the three core ceramics (P<0.05). Turkom-Cera showed the highest biaxial flexural strength, followed by In-Ceram and Vitadur-N.

    CONCLUSIONS: Turkom-Cera core had significantly higher flexural strength than In-Ceram and Vitadur-N ceramic core materials.

    Matched MeSH terms: Dental Materials/chemistry*
  2. Ho TK, Satterthwaite JD, Silikas N
    Dent Mater, 2018 02;34(2):e15-e24.
    PMID: 29175160 DOI: 10.1016/j.dental.2017.11.014
    OBJECTIVE: To assess the change in surface roughness of nanohybrid resin composite (Tetric EvoCeram) after antagonist wear against monolithic zirconia and lithium disilicate ceramics through a simulated chewing test using a three-dimensional (3D) profilometer.

    METHODS: A total of 40 Tetric EvoCeram™ resin composite specimens against either a Lava™ Plus zirconia antagonist (n=20) or IPS e.max Press lithium disilicate antagonist (n=20) were prepared for the study. The surface roughness profiles of each resin composite before and after an in-vitro simulated chewing test were analysed using a 3D profilometer and Talymap software. After the simulated chewing, the surface profiles of representative Tetric EvoCeram specimens from each group were analysed using scanning electron microscopy. Independent t-test and paired t-test were used for statistical analysis.

    RESULTS: For both lithium disilicate and zirconia groups, all surface roughness parameters (Ra, Rt, Sa, Sq,) of Tetric EvoCeram were significantly higher post-chewing compared to pre-chewing (p<0.05); the post-chewing surface roughness parameters of Tetric EvoCeram for the lithium disilicate group were significantly higher (p<0.05) than in the zirconia group.

    SIGNIFICANCE: This chewing simulation test showed that Tetric EvoCeram composites exhibited a rougher surface when opposing lithium disilicate ceramic compared to opposing zirconia ceramic.

    Matched MeSH terms: Dental Materials/chemistry*
  3. Kannaiyan K, Rathod A, Bhushan P, Mailankote S, Almuraikhi T, Daghriri A
    J Contemp Dent Pract, 2024 Mar 19;25(3):241-244.
    PMID: 38690697 DOI: 10.5005/jp-journals-10024-3612
    AIM: The current study was designed to assess the linear dimensional changes and adaptability of two heat-cured denture base resins using various cooling methods.

    MATERIALS AND METHODS: To prepare a total of 90 acrylic resin samples (45 acrylic resin samples for each material), four rectangular stainless-steel plates measuring 25 × 25 × 10 mm were fabricated. For both groups, the material was put into the mold at the dough stage. Group I - SR Triplex Hot Heat Cure acrylic; group II - DPI Heat Cure acrylic. Both groups used the same curing procedure. One of the following three techniques was used to cool the material (15 samples from each material) once the curing cycle was finished: (A) water bath, (b) quenching, and (C) air. A traveling microscope was used to measure the distance between the markings on the acrylic samples. The data was recorded and statistically analyzed.

    RESULTS: In SR Triplex Hot heat cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.242 ± 0.05), followed by the air technique (0.168 ± 0.11) and the least was found in the water bath technique (0.146 ± 0.01). In DPI Heat Cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.284 ± 0.09), followed by the air technique (0.172 ± 0.18) and the least was found in the water bath technique (0.158 ± 0.10). There was a statistically significant difference found between these three cooling techniques. On comparison of adaptability, the water bath technique, the marginal gap SR Triplex Hot was 0.012 ± 0.02 and DPI Heat Cure was 0.013 ± 0.02. In the quenching technique, the marginal gap SR Triplex Hot was 0.019 ± 0.04 and DPI Heat Cure was 0.016 ± 0.04. In the air technique, the marginal gap SR Triplex Hot was 0.017 ± 0.01 and DPI Heat Cure was 0.019 ± 0.01.

    CONCLUSION: The present study concluded that among the different cooling methods, the water bath technique had the least linear dimensional change, followed by the air and quenching techniques. When comparing the materials, DPI Heat Cure acrylic resin showed a greater linear dimensional change than SR Triplex Hot heat cure acrylic resin.

    CLINICAL SIGNIFICANCE: During polymerization, heat-cured acrylic resins experience dimensional changes. Shrinkage and expansion are dimensional changes that occur in heat-cured acrylic resins and have an impact on the occlusal relationship and denture fit. However, the denture base's material qualities and the different temperature variations it experiences during production may have an impact on this. How to cite this article: Kannaiyan K, Rathod A, Bhushan P, et al. Assessment of Adaptability and Linear Dimensional Changes of Two Heat Cure Denture Base Resin with Different Cooling Techniques: An In Vitro Study. J Contemp Dent Pract 2024;25(3):241-244.

    Matched MeSH terms: Dental Materials/chemistry
  4. Amer AAR, Abdullah MMAB, Liew YM, A Aziz IH, Wysłocki JJ, Tahir MFM, et al.
    Materials (Basel), 2021 Feb 26;14(5).
    PMID: 33652863 DOI: 10.3390/ma14051094
    The demand for durable, resistant, and high-strength structural material has led to the use of fibers as reinforcing elements. This paper presents an investigation into the inclusion of chopped steel wool fibers (CSWFs) in cement to form a high-flexural strength cementitious composite matrix (CCM). CSWFs were used as the primary reinforcement in CCM at increments of 0.5 wt%, from 0.5-6 wt%, with ratios of cement to sand of 1:1.5 and water to cement of 0.45. The inclusion of CSWFs resulted in an excellent optimization of the physicomechanical properties of the CCM, such as its density (2.302 g/cm3), compressive strength (61.452 MPa), and maximum flexural strength (10.64 MPa), all of which exceeded the performances of other reinforcement elements reported in the literature.
    Matched MeSH terms: Dental Materials
  5. Ahmad Fuad Ab Ghani, Mohd Irman Ramli, Ridhwan Jumaidin, Dharmalingam, Sivakumar, Fudhail Abdul Munir, Mohd Syukri Yob
    MyJurnal
    The study of Representative Volume Element (RVE) on Composite Material has been performed in the aim to obtain the relation and effect of fiber volume fraction on its tensile properties which is one of the important mechanical properties for composite designers in automotive and aerospace community.The properties such as fibre content, orientation, dimension of constituent fibres (diameter), level of intermixing of fibres, interface bonding between fibre and matrix, and arrangement of fibres between different types of fibres, influences the mechanical properties of hybrid composite.Representative Volume Element (RVE) for each constituent Carbon Fiber Reinforced Polymer (CFRP) and Glass Fiber Reinforced Polymer (GFRP) assumed isotropic behavior for carbon fibre, glass fibre and epoxy resin matrix and assumed to be perfectly bonded interface between fibre and matrix region i.e. strain compatibility at the interface. The scope of study on the micro mechanical modelling via representative volume element (RVE) is limited only to unidirectional composites.The result of parametric study performed deduces that incremental volume fraction of carbon and glass respectively will increase the E11 (Modulus of Elasticity in Tensile Direction) and enhance the tensile properties of both CFRP and GFRP.
    Matched MeSH terms: Dental Materials
  6. Huseien GF, Sam ARM, Faridmehr I, Baghban MH
    Materials (Basel), 2021 Mar 06;14(5).
    PMID: 33800835 DOI: 10.3390/ma14051255
    This research investigated the application of epoxy resin polymer as a self-healing strategy for improving the mechanical and durability properties of cement-based mortar. The epoxy resin was added to the concrete mix at various levels (5, 10, 15, and 20% of cement weight), and the effectiveness of healing was evaluated by microstructural analysis, compressive strength, and non-destructive (ultrasonic pulse velocity) tests. Dry and wet-dry conditions were considered for curing, and for generating artificial cracks, specimens at different curing ages (1 and 6 months) were subjected to compressive testing (50 and 80% of specimen's ultimate compressive strength). The results indicated that the mechanical properties in the specimen prepared by 10% epoxy resin and cured under wet-dry conditions was higher compared to other specimens. The degree of damage and healing efficiency index of this particular mix design were significantly affected by the healing duration and cracking age. An optimized artificial neural network (ANN) combined with a firefly algorithm was developed to estimate these indexes over the self-healing process. Overall, it was concluded that the epoxy resin polymer has high potential as a mechanical properties self-healing agent in cement-based mortar.
    Matched MeSH terms: Dental Materials
  7. Balagopal S, Nekkanti S, Kaur K
    J Contemp Dent Pract, 2021 Feb 01;22(2):134-139.
    PMID: 34257171
    AIM: The aim of this study was to examine and compare the flexural strength, shear bond strength, and fluoride-releasing ability of glass ionomer cement (GIC), Fuji IX GIC®, and a new alkasite filling material, Cention N®.

    MATERIAL AND METHODS: The materials were divided into two groups, Fuji IX GIC® (n = 30) and Cention N® (n = 30) and further divided (n = 10) to test three parameters, the fluoride releasing ability, flexural strength, and shear bond strength. Fluoride release was checked using fluoride ion-selective electrode, and flexural strength and shear bond strength were tested using universal testing machine (Intron 3366, UK).

    RESULTS: Fluoride release of Fuji IX GIC® was significantly higher compared to that of control Cention N® over a period of 21 days. Flexural strength of Cention N® was significantly higher compared to Fuji IX GIC® and there were no significant differences in shear bond strength of both the materials.

    CONCLUSION: From the results of the study, it can be concluded that Cention N® is an alkasite filling material for the complete and permanent replacement of tooth structure in posterior teeth and can be a good alternative when compared to GICs on the basis of their superior mechanical properties.

    CLINICAL SIGNIFICANCE: Cention N® is an innovative filling material for the complete and permanent replacement of tooth structure in posterior teeth and can be a good alternative when compared to GICs on the basis of their superior mechanical properties.

    Matched MeSH terms: Dental Materials
  8. Jadhav V, Deshpande S, Radke U, Mahale H, Patil PG
    J Prosthet Dent, 2021 Oct;126(4):590-594.
    PMID: 33012529 DOI: 10.1016/j.prosdent.2020.07.014
    STATEMENT OF PROBLEM: Xerostomia refers to the decrease in the quality and quantity of saliva. In denture wearers, xerostomia affects the retention of the denture because of lack of wettability of the denture base. However, which denture base resin materials are best wetted by artificial salivary substitutes is unclear.

    PURPOSE: The purpose of this in vitro study was to determine the wetting properties of 3 different commercially available denture base resin materials with artificial salivary substitute by using contact angle measurements and to compare these properties before and after thermocycling.

    MATERIAL AND METHODS: A total 120 specimens were fabricated with 3 different denture base materials (n=40): heat-polymerized polymethylmethacrylate (DenTek), injection-molded nylon polyamide (Valplast), and microwave polymerized (VIPI WAVE). The advancing and receding contact angles were measured with a goniometer by using the WinDrop++ software program. The contact angle hysteresis was calculated from the advancing and receding contact angles values. The same specimens were subjected to thermocycling to measure the advancing and receding contact angles values. The comparative evaluation was carried out before and after thermocycling.

    RESULTS: The mean ±standard deviation contact angles of the microwave-polymerized material were (62.40 ±1.21 degrees) advancing contact angle, (32.12 ±0.66 degrees) receding contact angle, and (30.28 ±1.40 degrees) contact angle of hysteresis. It was followed by the injection-molded nylon polyamide material, whose mean ±standard deviation contact angle values were (68.57 ±1.72 degrees) advancing contact angle, (43.02 ±1.39 degrees) receding contact angle, (26.27 ±2.05 degrees) contact angle hysteresis and high impact strength heat-polymerized polymethylmethacrylate material, whose mean ±standard deviation contact angle values were (69.81 ±0.16 degrees) advancing contact angle, (41.90 ±1.02 degrees) receding contact angle, and (27.91 ±0.97 degrees) contact angle hysteresis. The statistical analysis showed significant differences among contact angle values of the microwave-polymerized material as compared with the heat-polymerized polymethylmethacrylate and injection-molded nylon polyamide materials (P

    Matched MeSH terms: Dental Materials
  9. Ahmad Mahmood, Aws H. Ali Al-Kadhim, Zaripah Wan Bakar, Adam Husein
    Malaysian Dental Journal, 2011;32(1):12-16.
    MyJurnal
    Evaluation of the mechanical behaviour of restoration dental materials is essential to understand their performance under different load conditions and to estimate their durability under clinical oral function. Restorative materials and dental tissues like other materials by having specific mechanical properties, such as static strength (i.e. compressive strength, tensile strength, flexural strength) and dynamic strength (i.e. fatigue strength). The selection of proper mechanical test type depends on the goals that the study claims to define. On such basis, the mechanical test can be chosen correctly. Laboratory studies should be designed as replications of the clinical oral circumstances to measure the mechanical and physical properties of a material and any arbitrary choices in the design of the study may result in large variations of data.
    Matched MeSH terms: Dental Materials
  10. Zainab Shakir Radif, Aidy Ali
    MyJurnal
    The fracture behaviour represents the most critical issue in the automotive and aerospace engine fields. Thus, the objective of this study was to estimate and analyze the crack criteria by using the
    Mathematical laws that were limited in E 1820 standard and the results affirmed by applying the numerical solutions of ANSYS to estimate the fracture toughness value KIC, besides the energy release rate of biomass composite. The specimens were prepared from different percentage of kenaf mat (KM) and unsaturated polyester resin (UP) 20% KM – 80% UP and 40% KM – 60% UP, respectively, as well the other composite properties which were calculated using the stress-strain data. The fracture characterizations of this composite were carried out using the compact tension (CT) specimen that was commonly used to determine Mode-I fracture properties. The fracture toughness has been found to be independent of pre-crack length. Meanwhile, the tests were performed at room temperature. The numerical simulations of the ANSYS model results demonstrated a good agreement between the experiments computed results of the fracture toughness. The fracture toughness KIC of 20% KM – 80% UP and 40% KM – 60% UP was equivalent to 0.76 MPa√m and 2.0 MPa√m, respectively. Thus, the fracture propagation is dependent on the fibre percentage of the composite. On the other hand, there are unlimited mechanisms of crack paths derived from randomly kenaf mat packs, particularly in the frontal process zone of crack tip.
    Matched MeSH terms: Dental Materials
  11. Yanti Johari, Zaihan Ariffin, Haslina Taib, Norehan Mokhtar
    MyJurnal
    Resin-bonded fibre-reinforced composite bridges provide many advantages over the conventional
    bridges or implant treatment in the management of a traumatically or congenitally missing anterior tooth.
    Furthermore, there is an increasing demand towards providing a metal free resin-bonded bridges over the alloybased
    restorations in order to meet the aesthetic needs especially in the anterior region. Advances in the
    adhesive technology and tooth colored materials offer improved bonding system and better aesthetic outcome.
    Nevertheless, careful selection of cases to receive this type of approach is also one of the key factor to ensure
    the clinical survival of fibre-reinforced composite bridges. This report aims to present the use of fibre-reinforced
    composite to construct indirect cantilever fibre-reinforced composite bridges as part of minimum intervention
    dentistry.
    Matched MeSH terms: Dental Materials
  12. Ahmed T, Rahman NA, Alam MK
    Eur J Dent, 2018 10 30;12(4):602-609.
    PMID: 30369810 DOI: 10.4103/ejd.ejd_22_18
    The aim of this study was to systematically review the available studies measuring the bond strength of orthodontic bracket-adhesive system under different experimental conditions in vivo. Literature search was performed in four different databases: PubMed, Web of Science, Cochrane, and Scopus using the keywords - bond strength, orthodontic brackets, bracket-adhesive, and in vivo. A total of six full-text articles were selected based on the inclusion and exclusion criteria of our study after a careful assessment by the two independent reviewers. Data selection was performed by following PRISMA 2009 guidelines. Five of the selected studies were clinical trials; one study was a randomized clinical trial. From each of the selected articles, the following data were extracted - number of samples, with the type of tooth involved materials under experiment methods of measurement, the time interval between bonding and debonding orthodontic brackets, mode of force application, and the bond strength results with the overall outcome. The methodological quality assessment of each article was done by the modified Downs and Black checklist method. The qualitative analyses were done by two independent reviewers. Conflicting issues were resolved in a consensus meeting by consulting the third reviewer (MKA). Meta-analysis could not be performed due to the lack of homogenous study results. The review reached no real conclusion apart from the lack of efforts to clinically evaluate the bonding efficiency of a wide range of orthodontic bracket-adhesive systems in terms of debonding force compared to laboratory-based in vitro and ex vivo studies.
    Matched MeSH terms: Dental Materials
  13. Chong MM, Chang SY, Noraiham Muhammad, Zulkifli Mord Rosli, Qumrul Ahsan
    Sains Malaysiana, 2014;43:959-966.
    Dry sliding wear of polyester hybrid composites containing carboxylic functionalized multi-walled carbon nanotubes (cNT) and microparticles, silica (Si02) was studied at different sliding distances. An attempt has been made to produce uniform dispersion of nano- and micro- particles in the test samples by ultrasonication. The tribological properties of the hybrid composites were performed by using pin-on-disc (POD) tester against grey cast iron countersurface. The dry sliding wear tests were carried out under pressure-velocity (pv) condition of 0.4 MPa and 4 m/s for total sliding distance of 28800 m and at an interval of every sliding distance of 3600 m, wear properties and behavior were studied. The samples containing 10 wt.% silica (microparticles) with and without CNT always show increase in coefficient of friction at the expense of wear rate. However, samples containing only ci'rr have the lowest wear rate with the increase in coefficient of friction. Sliding distance studies also provide the information on wear rates which were ever changing at different sliding distances whereas average coefficient of friction did not vary throughout the tests. SEM observations of wear surfaces showed different wear morphologies when reinforcement (cNT or Si02) incorporated into the composites either alone or in combination.
    Matched MeSH terms: Dental Materials
  14. Nor Rabbi’atul ‘Adawiyah Norzali, Khairiah Badri, Mohd Zaki Nuawi
    Sains Malaysiana, 2011;40:1179-1186.
    Effects of aluminium hydroxide (ATH) addition on the properties of palm-based polyurethane composites were investigated. The hybrid composites were prepared by mixing 10 wt% of oil palm empty fruit bunch fiber (EFB) with ATH at varying amount of 2, 4 and 6 wt% of the overall mass of the resin. The compression stress and modulus gave the highest values of 575 and 2301 kPa, respectively at 2 wt% loading of ATH. The compression stress and modulus decreased drastically at 4 wt% (431 kPa and 1659 kPa, respectively) and further decreased at 6 wt% ATH (339 and 1468 kPa, respectively). However, the burning rate is inversely proportional to the loading percentage where the highest burning rate was observed at 2 wt% ATH. Sound absorption analysis indicated a large absorption coefficient at high frequency (4000 Hz) for all samples. The highest absorption coefficient was obtained from PU-EFB/ATH with 4 wt% ATH.
    Matched MeSH terms: Dental Materials
  15. Rahman SHBA, Irawan S, Shafiq N, Rajeswary R
    Heliyon, 2020 Feb;6(2):e03478.
    PMID: 32140594 DOI: 10.1016/j.heliyon.2020.e03478
    In selecting the binder composition for oil well application, its stability is an important design parameter. This paper presents the results of an experimental study conducted for comparing the linear expansion characteristics of geopolymer cement with the traditionally used ASTM Class G cement system. The expansion test was done in a water bath at 60 °C subjected to different curing intervals. The linear expansion of a cement system defines as the dimensional changes occur in the system, which is sometimes required to avoid the cement shrinkage during the hydration phase. In the case when the desired level of expansion is not achieved in the system, then the commercially available expandable materials are added in the class G cement system that enables the system to expand to the desired level. Shrinkage in the cementing system causes the formation of a microannulus or induces a gap that may allow the migration of fluid, hence the integrity of the system could be lost. This experimental study has revealed that the geopolymer cement tends to expand 0.15%-0.2% without the addition of any admixture, whereas the ASTM Class G cement has shown a lower value of linear expansion, which was obtained less than 0.1% after 18 days of curing. In the case of Class G cement, the addition of expandable material helped to increase the expansion; in the case of a geopolymer system, the additive has further accelerated the expansion.
    Matched MeSH terms: Dental Materials
  16. Rahaman Ali AAA, John J, Mani SA, El-Seedi HR
    J Prosthodont, 2020 Aug;29(7):611-616.
    PMID: 30637856 DOI: 10.1111/jopr.13018
    PURPOSE: To assess the impact of thermal cycling on flexural properties of denture base acrylic resin reinforced with microcrystalline cellulose (MCC) derived from oil palm empty fruit bunch (OPEFB).

    MATERIALS AND METHODS: The flexural strength and flexural modulus, following thermal cycling (5000 cycles of 5-55°C) of 3 MCC-reinforced poly methyl methacrylate (PMMA) specimens were compared with the conventional and commercially available high-impact PMMA. The 3 test groups were represented by addition of various weight combinations of MCC and acrylic powders.

    RESULTS: All 3 test groups with the addition of MCC demonstrated improved flexural strength and flexural modulus compared to the conventional resin, without and after thermal cycling. The highest mean flexural strength corresponded to the specimens reinforced with 5% MCC followed by 2% MCC.

    CONCLUSION: Addition of MCC derived from OPEFB to PMMA may be a viable alternative to the existing, commercially available synthetic reinforced PMMA resins. The potential application of natural fillers in the fabrication of a reinforced denture base resin needs further study.

    Matched MeSH terms: Dental Materials
  17. Chow ZP, Ahmad Z, Wong KJ, Koloor SSR, Petrů M
    Polymers (Basel), 2021 Feb 04;13(4).
    PMID: 33557350 DOI: 10.3390/polym13040492
    This paper aims to propose a temperature-dependent cohesive model to predict the delamination of dissimilar metal-composite material hybrid under Mode-I and Mode-II delamination. Commercial nonlinear finite element (FE) code LS-DYNA was used to simulate the material and cohesive model of hybrid aluminium-glass fibre-reinforced polymer (GFRP) laminate. For an accurate representation of the Mode-I and Mode-II delamination between aluminium and GFRP laminates, cohesive zone modelling with bilinear traction separation law was implemented. Cohesive zone properties at different temperatures were obtained by applying trends of experimental results from double cantilever beam and end notched flexural tests. Results from experimental tests were compared with simulation results at 30, 70 and 110 °C to verify the validity of the model. Mode-I and Mode-II FE models compared to experimental tests show a good correlation of 5.73% and 7.26% discrepancy, respectively. Crack front stress distribution at 30 °C is characterised by a smooth gradual decrease in Mode-I stress from the centre to the edge of the specimen. At 70 °C, the entire crack front reaches the maximum Mode-I stress with the exception of much lower stress build-up at the specimen's edge. On the other hand, the Mode-II stress increases progressively from the centre to the edge at 30 °C. At 70 °C, uniform low stress is built up along the crack front with the exception of significantly higher stress concentrated only at the free edge. At 110 °C, the stress distribution for both modes transforms back to the similar profile, as observed in the 30 °C case.
    Matched MeSH terms: Dental Materials
  18. Netramai S, Kijchavengkul T, Samsudin H, Lertsiri S
    Data Brief, 2020 Aug;31:105906.
    PMID: 32637506 DOI: 10.1016/j.dib.2020.105906
    Crude extracts of fresh Dendrobium Sonia 'Earsakul' orchid flowers (DSE) were prepared using microwave assisted extraction (MAE; using household microwave oven) and hot water extraction (HWE; at constant 80 °C). The obtained DSEs were measured their absorbance at λmax of 543 and 583 nm and determined their total monomeric anthocyanin contents (TAC). Mathematical models of MAE of Dendrobium Sonia 'Earsakul' orchid flower were constructed using response surface methodology - Box-Behnken design. Studied parameters included flower to water ratio, microwave power, and extraction time, with absorbance at λmax as response. The data generated were 1) visible spectrum (400-700 nm) of DSE; 2) absorbance values at λmax and 3) TAC of DSEs obtained from various extraction conditions of MAE and HWE; 4) linear equations describing correlations between TAC and absorbance at λmax of DSEs; and 5) mathematical models of MAE of Dendrobium Sonia 'Earsakul' orchid.
    Matched MeSH terms: Biomedical and Dental Materials
  19. Murali G, Amran M, Fediuk R, Vatin N, Raman SN, Maithreyi G, et al.
    Materials (Basel), 2020 Dec 11;13(24).
    PMID: 33322254 DOI: 10.3390/ma13245648
    Ferrocement panels, while offering various benefits, do not cover instances of low and moderated velocity impact. To address this problem and to enhance the impact strength against low-velocity impact, a fibrous ferrocement panel is proposed and investigated. This study aims to assess the flexural and low-velocity impact response of simply supported ferrocement panels reinforced with expanded wire mesh (EWM) and steel fibers. The experimental program covered 12 different ferrocement panel prototypes and was tested against a three-point flexural load and falling mass impact test. The ferrocement panel system comprises mortar reinforced with 1% and 2% dosage of steel fibers and an EWM arranged in 1, 2, and 3 layers. For mortar preparation, a water-cement (w/c) ratio of 0.4 was maintained and all panels were cured in water for 28 days. The primary endpoints of the investigation are first crack and ultimate load capacity, deflection corresponding to first crack and ultimate load, ductility index, flexural strength, crack width at ultimate load, a number of impacts needed to induce crack commencement and failure, ductility ratio, and failure mode. The finding revealed that the three-layers of EWM inclusion and steel fibers resulted in an additional impact resistance improvement at cracking and failure stages of ferrocement panels. With superior ultimate load capacity, flexural strength, crack resistance, impact resistance, and ductile response, as witnessed in the experiment program, ferrocement panel can be a positive choice for many construction applications subjected to repeated low-velocity impacts.
    Matched MeSH terms: Dental Materials
  20. Hashim MKR, Abdul Majid MS, Jamir MRM, Kasim FH, Sultan MTH
    Polymers (Basel), 2021 Jan 31;13(3).
    PMID: 33572609 DOI: 10.3390/polym13030455
    In this paper, the effects of stacking sequence and ply orientation on the mechanical properties of pineapple leaf fibre (PALF)/carbon hybrid laminate composites were investigated. The hybrid laminates were fabricated using a vacuum infusion technique in which the stacking sequences and ply orientations were varied, which were divided into the categories of cross-ply symmetric, angle-ply symmetric, and symmetric quasi-isotropic. The results of tensile and flexural tests showed that the laminate with interior carbon plies and ply orientation [0°, 90°] exhibited the highest tensile strength (187.67 MPa) and modulus (5.23 GPa). However, the highest flexural strength (289.46 MPa) and modulus (4.82 GPa) were recorded for the laminate with exterior carbon plies and the same ply orientation. The fracture behaviour of the laminates was determined by using scanning electron microscopy, and the results showed that failure usually initiated at the weakest PALF layer. The failure modes included fibre pull-out, fibre breaking, matrix crack, debonding, and delamination.
    Matched MeSH terms: Dental Materials