Displaying publications 21 - 40 of 46 in total

Abstract:
Sort:
  1. Rahmat S, Rahman SA, Tukiran NH, Musa R, Othman NA, Dzulkarnain AAA
    Med J Malaysia, 2021 03;76(2):205-211.
    PMID: 33742629
    OBJECTIVE: This study is a preliminary work to develop a Malay version questionnaire named 'Inventori Persepsi bagi Muslim yang Memiliki Masalah Pendengaran (IPM3P)' to assess the perception on Islamic understanding and practice among Muslim adults with hearing impairment.

    METHODS: The scale development involved three phases: i) generation of domains based on the literature, ii) generation of sub-domains based on literature review and Islamic panel survey, and iii) generation of items.

    RESULTS: Preliminary version of IPM3P consists of 59 items was produced, representing three domains: Obligation (18 items), Practice (21 items), and Difficulty (20 items), and seven sub-domains ('Ibadah', 'Aqidah', 'Muamalat', 'Tasawwuf', 'Akhlak','Da'wah', and 'Sirah').

    CONCLUSION: The preliminary version of IPM3P needs to be psychometrically tested. This pioneering study may become an impetus towards more research pertaining to understanding the effect of hearing loss towards religious life in the future in Malaysia.

    Matched MeSH terms: Deafness
  2. Noraidah Ismail, Sarah Rahmat
    MyJurnal
    This paper aims to synthesize available literature on occupational noise in Malaysia and to relate this to the current noise management practices and control. The review focuses on several main
    scopes; i) history of occupational noise management in Malaysia; ii) legislative developments and legal precedents of occupational noise in Malaysia ; and iii) the hearing conservation programs (HCP) and hearing loss prevention programs (HLPP). Narrative review and synthesis. Related publications and references were identified through several ways: i) by structured searches in PubMed, Google scholar, Web of Knowledge and Science Direct using the combinations of ‘occupational noise’, ‘noise induced hearing loss; ‘hearing’, ‘knowledge’, awareness’, ‘hearing conservation program’, ‘hearing protection devices’ as key words ii) by inspecting the reference lists of relevant articles. The number of publications within the audiology which address this topic, is rather limited. All the above mentioned scopes were discussed and synthesis of literature from other related fields such as medical, health and occupational safety and health were also referred to facilitate the discussion. This paper concludes that there are an emerging trend for the studies of occupational noise Malaysia in the literature. However, the effectiveness of HCP in Malaysia, and to what extent it is accepted and being implemented is yet to be investigated.
    Matched MeSH terms: Deafness
  3. Tengku Zulaila Hasma Tengku Zam Zam, Ahmad Aidil Arafat Dzulkarnain, Sarah Rahmat, Masnira Jusoh
    MyJurnal
    Patient’s self-perceived handicap inventory is an important tool for modern’s health care management including hearing loss. The HHIA is a selfreporting outcome measurement invented to identify hearing-impaired patients’ complaints for appropriate client-centred rehabilitation program. HHIA has been
    reported among one of the valid self-perceived hearing handicap measures, and could even addressed issues for patient with mild and unilateral hearing loss. This study aims to translate HHIA into Malay language (HHIA-M) and to adapt the questionnaire culturally for clinical use among Malaysian population.
    Matched MeSH terms: Deafness
  4. Abdul Rahim KA, Jewaratnam J, Che Hassan CR, Hamid MD
    PMID: 33142732 DOI: 10.3390/ijerph17218032
    Occupational noise-induced hearing loss (ONIHL) is the most reported occupational disease in Malaysia. ONIHL is aggravated by the presence of early hearing loss amongst the youth prior to entering a real working environment. At technical and vocational education training (TVET) institutions, students may develop early ONIHL because training workshops are designed imitating the industrial working environment to produce skilled workers. The exceeding noise level at workshops and recent risk of non-occupational noise can cause early ONIHL among these students. Therefore, ONIHL must be addressed at the early stage of producing skilled workers. Octa hearing conservation index (OHCI) system is developed as a management and monitoring tool for hearing conservation program (HCP) in TVET institutions. Six existing and two new HCP components were used to build the index system. A pilot test on the effectiveness of the OHCI system was conducted in a selected TVET institution for six months. The post-HCP shows a 52.6% improvement compared to the pre-HCP. The implementation of HCP has shown improved awareness on the hazards of loud noise exposure and active use of hearing protection devices among participants. The OHCI system has a great potential as a tool to improve HCP implementation in TVET institutions, and eventually, industry.
    Matched MeSH terms: Deafness
  5. Ahmad Syazrin Muhamad
    MyJurnal
    Sound is one of the source of energy generated by vibration and is carried through the air in a form of pressure waves (Frederick, 1975). This pressure waves consist of pulsation or vibration of molecules of an elastic medium such as gas, liquid and even solid (Gerber, 1974). Due to its nature, sound can be irritating when it is excessive. The excessive amount of sound is called noise. Exposure to noise is common to the workers working at the industry. This can lead to hearing loss. Hearing loss is one of the most common health problems in the industrialized world. Working activities have been related to noise exposure due to increase use of machine that generates sounds. Many workers throughout the world experience hazardous noise exposure which is ≥ 85 decibels (dB) (Seter, 1998). Based on the previous study in the European region, most of the employers had difficulties to compensate workers diagnosed with hearing loss or hearing impairment cause by the working nature. (Rachiotis et al., 2006). According to European Survey on Working Conditions, about 7% of the workers considered that their work affects their health in the form of hearing disorders. Occupational risk factors for hearing loss include occupational noise, whole body vibration, work-related diseases and exposure to chemical. In this report, we specified in the noise exposure level of the workers.
    Matched MeSH terms: Deafness
  6. Ramli, M., Fatnoon, N.N.A., Rohaidah, S.A.
    MyJurnal

    Wolfram syndrome (WFS) is a rare neurodegerative disorder which is characterized by presentation of diabetes insipidus, juvenile diabetes mellitus, optic atrophy and deafness. We describe a case of WFS with presentation of psychosis. A 17-year-old female presented with psychiatric manifestations, namely inappropriate behaviour and second person auditory hallucination since the age of 16 years. The patient was diagnosed with type 1 diabetes mellitus at the age of 10 years old and subsequently progressive hearing and visual loss a year later. Her ophthalmic evaluation revealed total blindness due to optic atrophy. However she did not have renal dysfunction and diabetes insipidus which are also features of the syndrome. There is scarce literature to describe on psychiatric presentation in WFS. In the past, the psychiatric manifestation which was reported most of times was mood and suicidal behaviour. Hardly any article reported about psychosis (hallucination). We believe, her psychiatric manifestations were related to sensory deprivation due to blindness and deafness caused by the progression of WFS.
    Matched MeSH terms: Deafness
  7. Chew-Ean T, Othman K, Alexander SM, Shatriah I
    Cureus, 2017 Nov 02;9(11):e1814.
    PMID: 29308342 DOI: 10.7759/cureus.1814
    Hearing loss is rarely associated with sympathetic ophthalmia. We describe a young man who presented with sympathetic ophthalmia and concurrent hearing loss one month post globe rupture. The presentation was very subtle and atypical. However, the patient recovered fully after two weeks of prompt oral corticosteroid therapy which resulted in good visual and hearing outcomes. This patient demonstrated that the acute phase of sympathetic ophthalmia is reversible with early recognition of features, timely diagnosis, and rapid initiation of corticosteroid therapy.
    Matched MeSH terms: Deafness
  8. Rus RM, Daud A, Musa KI, Naing L
    Malays J Med Sci, 2008 Oct;15(4):28-34.
    PMID: 22589635
    The purpose of this study was to determine the sawmill workers' knowledge, attitude and practice (KAP) in relation to noise-induced hearing loss (NIHL). A cross-sectional study was conducted involving 83 workers from 3 factories in Kota Bharu, Kelantan. Questionnaires were distributed to obtain the socio-demography, knowledge, attitude and practice level in relation to noise-induced hearing loss (NIHL). The weak areas identified in the knowledge section were treatment aspects (15.5%), signs and symptoms of NIHL (20.2%) and risk factors (31%). As for attitude; the prevention aspects were the lowest (25.3%), followed by risk taking attitude (26.2%), and causes of hearing loss (42.1%). Overall, the practice was not encouraging at all. It is important to have an education program to raise workers' awareness and to improve their attitude and practices towards noise-induced hearing loss.
    Matched MeSH terms: Deafness
  9. Umat C, McDermott HJ, McKay CM
    J Am Acad Audiol, 2006 12 13;17(10):733-46.
    PMID: 17153721
    This study investigated the effect of intensity on pitch in electric hearing and its relationship to the speech perception ability of cochlear implantees. Subjects were 13 adult users of the Nucleus 22 cochlear implant system, using either the Spectra22 or ESPrit22 speech processor and the SPEAK speech processing strategy. A multidimensional scaling technique was employed. Speech perception was measured using sentences and vowels. All measurements were performed in a soundfield condition, and subjects wore their own speech processors with their normally used settings. Results showed a significant correlation between the degree of deviation of the subjects' stimulus spaces from the "ideal" space and subjects' performance with the sentences, but not with the vowels. A significant correlation was found between subjects' response variability in performing the multidimensional scaling task and their speech perception measures, suggesting that spectral smearing or underlying cognitive abilities might affect implantees' speech perception performance.
    Matched MeSH terms: Deafness/radiotherapy*
  10. Elango S, Htun YN, Raza H
    Int J Pediatr Otorhinolaryngol, 1994 Jan;28(2-3):125-8.
    PMID: 8157410
    A total of 165 children from a school for the deaf in Malaysia were screened to find out the prevalence of additional conductive hearing loss. Otological examination, tympanometry and pure tone audiometry were performed in all these children. Fifty-one children (30.9%) had additional conductive hearing loss. Middle ear disorders were present in 15 children (9.09%). The deaf children seldom complain about the change in their hearing sensitivity, so there is a need for regular otological examination in deaf children to detect the additional conductive hearing loss.
    Matched MeSH terms: Deafness/diagnosis*
  11. Zulkaflay AR, Saim L, Said H, Mukari SZ, Esa R
    Med J Malaysia, 1996 Mar;51(1):103-8.
    PMID: 10967988
    Despite the commonly observed condition of middle and inner ear barotrauma among divers, there is little evidence of insidious and permanent development of sensorineural hearing loss associated with diving. An audiometric survey was performed on a group of 120 divers and 166 non divers from the Royal Malaysian Naval Base in Lumut, West Malaysia between July to December 1991. The results of this survey revealed that insidious development of high frequency sensorineural hearing loss may be associated with diving. At frequencies 4000, 6000 and 8000 Hz the divers had higher mean hearing levels than non divers and their hearing at those frequencies seemed to deteriorate faster. The etiology of this insidious hearing loss is multifactorial and may be related to inner ear barotrauma, decompression sickness or noise-induced deafness.
    Matched MeSH terms: Deafness/etiology*
  12. Hariharan M, Sindhu R, Vijean V, Yazid H, Nadarajaw T, Yaacob S, et al.
    Comput Methods Programs Biomed, 2018 Mar;155:39-51.
    PMID: 29512503 DOI: 10.1016/j.cmpb.2017.11.021
    BACKGROUND AND OBJECTIVE: Infant cry signal carries several levels of information about the reason for crying (hunger, pain, sleepiness and discomfort) or the pathological status (asphyxia, deaf, jaundice, premature condition and autism, etc.) of an infant and therefore suited for early diagnosis. In this work, combination of wavelet packet based features and Improved Binary Dragonfly Optimization based feature selection method was proposed to classify the different types of infant cry signals.

    METHODS: Cry signals from 2 different databases were utilized. First database contains 507 cry samples of normal (N), 340 cry samples of asphyxia (A), 879 cry samples of deaf (D), 350 cry samples of hungry (H) and 192 cry samples of pain (P). Second database contains 513 cry samples of jaundice (J), 531 samples of premature (Prem) and 45 samples of normal (N). Wavelet packet transform based energy and non-linear entropies (496 features), Linear Predictive Coding (LPC) based cepstral features (56 features), Mel-frequency Cepstral Coefficients (MFCCs) were extracted (16 features). The combined feature set consists of 568 features. To overcome the curse of dimensionality issue, improved binary dragonfly optimization algorithm (IBDFO) was proposed to select the most salient attributes or features. Finally, Extreme Learning Machine (ELM) kernel classifier was used to classify the different types of infant cry signals using all the features and highly informative features as well.

    RESULTS: Several experiments of two-class and multi-class classification of cry signals were conducted. In binary or two-class experiments, maximum accuracy of 90.18% for H Vs P, 100% for A Vs N, 100% for D Vs N and 97.61% J Vs Prem was achieved using the features selected (only 204 features out of 568) by IBDFO. For the classification of multiple cry signals (multi-class problem), the selected features could differentiate between three classes (N, A & D) with the accuracy of 100% and seven classes with the accuracy of 97.62%.

    CONCLUSION: The experimental results indicated that the proposed combination of feature extraction and selection method offers suitable classification accuracy and may be employed to detect the subtle changes in the cry signals.

    Matched MeSH terms: Deafness/physiopathology
  13. Woei TJ, Mazlan R, Tamil AM, Rosli NSM, Hasbi SM, Hashim ND, et al.
    Int Tinnitus J, 2023 Dec 04;27(1):75-81.
    PMID: 38050889 DOI: 10.5935/0946-5448.20230013
    OBJECTIVE: The purpose of this study was to compare the reliability and accuracy of chirp-based Multiple Auditory Steady State Response (MSSR) and Auditory Brainstem Response (ABR) in children.

    METHODS: The prospective clinical study was conducted at Selayang Hospital (SH) and Hospital Canselor Tuanku Muhriz (HCTM) within one year. A total of 38 children ranging from 3 to 18 years old underwent hearing evaluation using ABR tests and MSSR under sedation. The duration of both tests were then compared.

    RESULTS: The estimated hearing threshold of frequency specific chirp MSSR showed good correlation with ABR especially in higher frequencies such as 2000 Hz and 4000Hz with the value of cronbach alpha of 0.890, 0.933, 0.970 and 0.969 on 500Hz, 1000Hz, 2000Hz and 4000Hz. The sensitivity of MSSR is 0.786, 0.75, 0.957 and 0.889 and specificity is 0.85, 0.882, 0.979 and 0.966 over 500Hz, 1000Hz, 2000Hz and 4000Hz. The duration of MSSR tests were shorter than ABR tests in normal hearing children with an average of 35.3 minutes for MSSR tests and 46.4 minutes for ABR tests. This can also be seen in children with hearing loss where the average duration for MSSR tests is 40.0 minutes and 52.0 minutes for ABR tests.

    CONCLUSION: MSSR showed good correlation and reliability in comparison with ABR especially on higher frequencies. Hence, MSSR is a good clinical test to diagnose children with hearing loss.

    Matched MeSH terms: Deafness*
  14. Kong MH, Goh BS, Hamidah A, Zarina AL
    Med J Malaysia, 2014 Feb;69(1):9-12.
    PMID: 24814621 MyJurnal
    OBJECTIVE: This study aimed to evaluate the prevalence of sensorineural hearing loss (SNHL) in β-thalassaemia patients treated with Desferrioxamine (DFO) and determine the correlation of SNHL with average daily DFO dosage, serum ferritin level and Therapeutic index (T.I).

    METHODS: This is a cross sectional descriptive study carried out for a period of 14 months and 54 patients were recruited. The recruited patients are transfusion dependant β- thalassaemia patient aged 3 years and above treated with DFO. An interview, clinical examination and hearing assessment, which included tympanogram, and Pure Tone Audiometry (PTA) or behaviour alaudiometry were performed. The data on age started on DFO, average daily DFO, duration of DFO intake, serum ferritin past 1 year and Therapeutic Index (T.I) were obtained from patients' case notes.

    RESULTS: The prevalence of SNHL was 57.4% and majority has mild hearing loss (93.6%). Fourteen patients (25.9%) have bilateral ear involvement and as many as 17 patients (31.5%) have SNHL in either ear. A total of 23 patients (42.6%) have normal hearing level. Although the prevalence of SNHL was 57.4%, only a small percentage of the patient noticed and complained of hearing loss (11.1%). There is no association between age started on DFO, average daily DFO and duration of DFO intake with normal hearing group and those patients with SNHL. Positive correlation was seen between average daily DFO with 2000 and 4000Hz on PTA in the left ear and between serum ferritin level past 1 year with 4000 and 8000Hz in the right ear and 8000Hz in the left ear. No significant correlation was seen between T.I on PTA.

    CONCLUSION: The prevalence of SNHL from hearing assessment is high in β-thalassaemia patients in this study. However, it is manifested clinically in a smaller percentage. We suggest a baseline hearing assessment should be carried on all β-thalassaemia patients prior to DFO chelation therapy.
    Matched MeSH terms: Deafness
  15. Subha ST, Nordin AJ
    Iran J Otorhinolaryngol, 2018 Nov;30(101):361-364.
    PMID: 30560103
    Introduction: Metastatic tumors of the temporal bone are extremely rare. Collet-Sicard syndrome is an uncommon condition characterized by unilateral palsy of the lower four cranial nerves. The clinical features of temporal bone metastasis are nonspecific and mimic infections such as chronic otitis media and mastoiditis.

    Case Report: This report describes a rare case of metastatic adenocarcinoma of the temporal bone causing Collet-Sicard syndrome, presenting with hearing loss, headache and ipsilateral cranial nerve palsies. The patient was a 68-year old woman initially diagnosed with extensive mastoiditis and later confirmed as having metastatic adenocarcinoma of the temporal bone, based on histopathologic findings.

    Conclusion: Clinical presentation of metastatic carcinoma of the temporal bone can be overshadowed by infective or inflammatory conditions. This case report is to emphasize the point that a high index of clinical suspicion is necessary for the early diagnosis of this aggressive disease which carries relatively poor prognosis. This report highlights that it is crucial to suspect malignant neoplasm in patients with hearing loss, headache and cranial nerve palsies.

    Matched MeSH terms: Deafness
  16. Nursakinah Abd Ghani, Wan Ahmad Wan Aslynn
    MyJurnal
    Introduction: The aim of this study is to determine the satisfaction level of hearing aid users in different types and degrees of hearing loss using the satisfaction with amplification in daily life (SADL) questionnaire. Methods: 35 hearing aid users with different types of hearing loss who sought help from the International Islamic University, Malaysia (IIUM) Hearing and Speech Clinic at Jalan Hospital Campus, Kuantan, IIUM Medical Specialist Centre and private hearing aid centres were involved in this study. The data was collected from the participants who filled in the Malay SADL questionnaires. Results: Among the thirty-five (35) participants, there was no significant difference reported between the types of hearing loss and their satisfaction level in the SADL global score and each of the subscales. It was found that satisfaction level with the hearing aids may depend on several factors such as cosmetic preference, cost of hearing aid and audiologist competence. Meanwhile, in terms of degrees of hearing loss, 80% of the users were relatively satisfied with their hearing aids. Yet, there was no correlation between hearing aid users’ satisfaction level and their degrees of hearing loss for all subscales and SADL global score. Conclusions: This study indicates that although hearing aid users reported to be satisfied with their hearing aids; there are some who are not satisfied in terms of feedback, telephone use, cosmetic appearance and costs of hearing aid. The findings of this study can benefit the audiologists, as they would be able to use the information to help future patients understand and adapt to the use of the hearing aids better.
    Matched MeSH terms: Deafness
  17. Mukari SZMS, Wan Hashim WF
    Ann Otol Rhinol Laryngol, 2018 Nov;127(11):798-805.
    PMID: 30139270 DOI: 10.1177/0003489418795982
    INTRODUCTION: The aims of this study were to examine the validity of self-perceived hearing loss in detecting hearing loss and factors associated with self-perceived hearing loss and hearing-help seeking and to report hearing aid adoption among a group of community-dwelling older adults in Malaysia.

    METHODS: A total of 301 older adults (⩾60 years of age) participating in a study on aging had their hearing tested using pure-tone audiometry. Self-perceived hearing loss was assessed using a single question. Sociodemographic profile, otologic history, and general cognitive status were also obtained.

    RESULTS: A single question had low sensitivity in detecting actual hearing loss: 31.3% for 4-frequency average > 25 dBHL and 48.8% for 4-frequency average > 40 dBHL. Besides hearing level, history of otorrhea and tinnitus were factors that were associated with self-perceived hearing loss among older adults with at least mild hearing loss. Hearing-help-seeking behavior was not associated with any of the tested variables. The hearing aid adoption rate was 2.7% and 7.3% among participants with 4-frequency averages > 25 dBHL and > 40 dBHL, respectively.

    CONCLUSION: The underestimation of hearing loss in the majority of older adults in this study poses a potential barrier to hearing loss intervention.

    Matched MeSH terms: Deafness
  18. Narayanan DA, Raman R, Chong AW
    Turk Arch Otorhinolaryngol, 2019 Sep;57(3):122-126.
    PMID: 31620693 DOI: 10.5152/tao.2019.3875
    Objective: The objectives are to determine and compare the degrees of hearing loss upon occlusion of the cartilaginous and the bony portion of the external ear canal (EAC).

    Methods: There were 20 healthy participants with normal ears, and all gave an informed consent. After an otoscopy, a baseline pure tone audiogram (PTA) was conducted. If the PTA of the participant was normal, aqueous cream was applied with a syringe via an 18 G cannula, from the tympanic membrane up to the isthmus which corresponds to the bony ear canal. A second PTA was conducted, and subsequently the cream was removed via suction under microscope guidance. The procedure was then repeated with the cream applied from the isthmus to the aperture of the external ear canal using the same cannula followed by a PTA and removal of cream under microscope.

    Results: The mean threshold difference of occlusion at both portions of the ear canal were compared and analyzed. The mean threshold difference of hearing loss upon occlusion at the cartilaginous EAC was 37.5 to 48 dB. The mean threshold difference of hearing loss upon occlusion at the bony EAC was less, with a range of 21 to 24.95dB. There was a statistical difference (p<0.05) in the hearing loss between the blockage of the cartilaginous canal versus the blockage of the bony canal with a maximum difference at 2kHz.

    Conclusion: Cartilaginous block of the external ear canal causes more hearing loss than block of the bony ear canal. This correlates with the concept and properties of sound waves, resonance and impedance.

    Matched MeSH terms: Deafness
  19. Chong AW, Raman R
    Indian J Otolaryngol Head Neck Surg, 2017 Sep;69(3):291-295.
    PMID: 28929057 DOI: 10.1007/s12070-017-1071-z
    Keratosis obturans appears to be an obscure and relatively uncommon entity, even in literature search of journals and reference texts, so much so that there is not even any prevalence or incidence statistics available. However, the condition did not appear to be as uncommon based on our clinical observations. We have managed to obtain 64 patients representing 67 ears with keratosis obturans in our study period of about 18 months with a pattern of occurrence during this period. Humid weather seemed to play a role in the frequency of its appearance during certain period in our observation. There also appears to be a correlation between the severity of symptoms (predominantly pain and hearing loss) and the presenting appearance of the condition, i.e., presence or absence of granulation tissue, as well as that the degree of difficulty in exenteration of the keratosis obturans (matrix and content) depending on the expansion of the bony canal. Our figures showed the majority of the patients are females and young individuals, the majority of them occur unilaterally. The condition also appear to stop short of involving the tympanic membrane with only the bony canal being expanded with the surrounding oedema creating an apparent "canal stenosis".
    Matched MeSH terms: Deafness
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links