MATERIALS AND METHODS: The processing technique described the incorporation of the preshaped "wax-bolus" during packing procedure of the Obturtor prosthesis and eliminated later by melting it once the curing procedure is completed.
RESULTS: This article is a single step procedure resulting into the closed-hollow obturator as single unit with uniform wall thickness around the hollow space ensuring the least possible weight of the hollow obturator.
CONCLUSION: This processing technique achieves predictable internal dimension of the hollow space providing uniform wall thickness of the obturator.
Materials and Methods: Gait analysis was performed in 20 patients with endoprosthesis replacement around the knee. The temporal parameters assessed during gait analysis were walking velocity, stride length, duration of stance, and goniometry of the knee. These parameters were compared with the functional outcome score of the MSTS.
Results: The mean free-paced walking velocity was 0.91 m/s (normal is 1.33 m/s), which was 68% lower than normal gait. The stride length and stance phase were shorter for the affected limb compared to normal (P < 0.05). However, the gait was symmetrical with no difference in stride length (P = 0.148), velocity (P = 0.918), knee flexion (P = 0.465), and knee extension (P = 0.321) between the affected and unaffected limbs. Sixteen patients demonstrated stiff knee gait, two had a flexed knee gait, and only two patients had normal gait during the stance phase. The mean MSTS score was 21. There was significant correlation between overall MSTS scores (P = 0.023), function (P = 0.039), and walking scores (P = 0.007).
Conclusion: Limb salvage surgery with endoprosthesis reconstruction around the knee gives good functional outcome, both objectively and subjectively, as evidenced by the symmetrical gait pattern and significant correlation with MSTS score. Despite decreased walking velocity, stride length, and stance phase of the operated limb, the patient still has a symmetrical gait.
PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.
MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.
RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (P
Methods: A three-unit bridge master model was fabricated using cold-cure acrylic resin. Four combinations of different viscosities of PVS impression materials - regular body (monophase) alone, light body with regular body, light body with heavy body, and light body with putty - were used to make an impression of the master model. Ten impressions from each group were taken and Type IV gypsum stone was used to generate the dies. The dies were measured at the inter-abutment distance, occlusogingival length, and shoulder width with a measuring microscope and were compared with the master model using one-way analysis of variance and Tukey (honest significant difference) test.
Results: Differences were found for inter-abutment distance between the master model and the light body with regular body and light body with putty dies (both P < 0.02). A difference was found for shoulder width between the master model and the regular body alone die (P = 0.01). No differences were found for occlusogingival distance (all P > 0.08).
Conclusion: Results suggested inter-abutment distance was most accurate when using a PVS light body combination. Occlusogingival length was accurate using any of the studied PVS combinations, and shoulder width was more accurate when using the regular body PVS.
Relevance for patients: These results should be considered when choosing the viscosity of the PVS to use for producing impressions of high accuracy and fabricating a well-fitting fixed prosthesis.