Displaying publications 21 - 40 of 101 in total

Abstract:
Sort:
  1. Singh, S., Choon, S.K., Tai, C.C.
    Malays Orthop J, 2008;2(2):34-36.
    MyJurnal
    We describe herein a modified technique for reconstruction of chronic rupture of the quadriceps tendon in a patient with bilateral total knee replacement and distal realignment of the patella. The surgery involved the application of a Dacron graft and the ‘double eights’ technique. The patient achieved satisfactory results after surgery and we believe that this technique of reconstruction offers advantages over other methods.
    Matched MeSH terms: Prostheses and Implants
  2. Radzi, Z., Yahya, N.A., Zamzam, N., Spencer, R.J.
    Ann Dent, 2004;11(1):-.
    MyJurnal
    Missing teeth can be due to hypodontia, trauma or extraction. In general, the options for treatment depend on the severity of the hypodontia and the severity of the malocclusion. Occasionally, the space from missing teeth has to be maintained for prosthetic replacement and require an orthodontic/restorative approach. It is very important to ensure the space maintained is adequate for aesthetic reason so that it can be replaced with a prosthesis after the orthodontic treatment is completed. This article discusses a new innovation and clinical technique for maintaining this space during orthodontic treatment by using an acrylic tooth with several modifications. This innovation will be illustrated using two cases.
    Matched MeSH terms: Prostheses and Implants
  3. Abdul Aziz, A, Ahmad, S.F., Muslim, Y.R
    Ann Dent, 2006;13(1):34-38.
    MyJurnal
    This clinical case report details the clinical sequence of a 78-year-old male receiving prosthetic rehabilitation using an implant-supported screwretained fixed partial denture. Despite the limitations imposed, the aesthetic and functional demands of the patient were fulfilled by this prosthetic rehabilitation. The importance of detailed prosthetic planning and evaluation prior to implant surgery is essential, therefore ideally, it should be done by the same operator or a team of operators working together. Problems can arise when the construction of the prosthesis is performed by other people who are not involved in the planning stage.
    Matched MeSH terms: Prostheses and Implants
  4. Awang, R.A.R., Arief, E.M., Hassan, A.
    MyJurnal
    Since the establishment of implant in dentistry, the use of removable partial denture in replacing missing teeth apparently becomes less popular. The situation is made worse by the renowned limitations of removable partial denture. One of the obvious limitations of removable partial denture, especially in replacing missing anterior teeth is the unsightly view of metal used for retentive clasp. This case report describes the use of spring loaded plunger attachments as an alternative way to achieve retention and at the same time improving the aesthetic of the prosthesis.
    Matched MeSH terms: Prostheses and Implants
  5. Faisal, A., Ahmad, S.H., Zulmi, W.
    MyJurnal
    Tumour surgery for locally extensive malignant neoplasms of the extremity will sometimes result in extensive composite soft tissue defect. Local flaps are usually inadequate to cover these large defects. More than one tissue flap might be required to cover any exposed neurovascular structures, bone or prosthesis. We present two cases where two composite flaps were simultaneously used to cover extensive surgical defects after ablative tumour resections in the extremity. These resulted in uncomplicated wound healing and limb salvage.
    Matched MeSH terms: Prostheses and Implants
  6. Aytekin K, Esenyel CZ
    Malays Orthop J, 2018 Mar;12(1):45-47.
    PMID: 29725513 DOI: 10.5704/MOJ.1803.010
    Hip arthroplasty is an extremely satisfying treatment method for coxarthrosis which is in increasing use throughout the world. However, loosening of the prosthesis is a significant complication and to overcome this, ceramic liners are increasingly being selected. If the survival of ceramic surfaces is prolonged, there is a risk of fracture of the ceramic materials. New ceramic materials developed to overcome this problem are more resistant. The case presented here is of a patient in whom liner fracture developed following ceramic-ceramic hip arthroplasty. The ceramic femoral head was observed to have protruded into the defect created in the acetabular component. Acetabular revision was applied to the patient.
    Matched MeSH terms: Prostheses and Implants
  7. Naji, Ghassan Abdul-Hamid, Ros Anita Omar, Rosiyah Yahya
    MyJurnal
    The mismatch in coefficient of thermal expansion (CTE) between the veneered
    porcelain and the ceramic core has been primarily identified as the cause of core/veneer chipping
    in all-ceramic restorations. This study aimed to evaluate the effect of sodalite infiltration on the
    CTE behaviour and bond strength of different all-ceramic prostheses. Materials and Methods: The
    experimental groups were synthesised sodalite-infiltrated alumina (IA-SOD) and synthesised
    sodalite-infiltrated zirconia-toughened alumina (ZTA) (IZ-SOD), while the control groups were glassinfiltrated alumina (IA-glass) and glass-infiltrated ZTA (IZ-glass). (Copied from article).
    Matched MeSH terms: Prostheses and Implants
  8. Hamidi MFFA, Harun WSW, Samykano M, Ghani SAC, Ghazalli Z, Ahmad F, et al.
    Mater Sci Eng C Mater Biol Appl, 2017 Sep 01;78:1263-1276.
    PMID: 28575965 DOI: 10.1016/j.msec.2017.05.016
    Biocompatible metals have been revolutionizing the biomedical field, predominantly in human implant applications, where these metals widely used as a substitute to or as function restoration of degenerated tissues or organs. Powder metallurgy techniques, in specific the metal injection moulding (MIM) process, have been employed for the fabrication of controlled porous structures used for dental and orthopaedic surgical implants. The porous metal implant allows bony tissue ingrowth on the implant surface, thereby enhancing fixation and recovery. This paper elaborates a systematic classification of various biocompatible metals from the aspect of MIM process as used in medical industries. In this study, three biocompatible metals are reviewed-stainless steels, cobalt alloys, and titanium alloys. The applications of MIM technology in biomedicine focusing primarily on the MIM process setting parameters discussed thoroughly. This paper should be of value to investigators who are interested in state of the art of metal powder metallurgy, particularly the MIM technology for biocompatible metal implant design and development.
    Matched MeSH terms: Prostheses and Implants
  9. Soundhar A, Zubar HA, Sultan MTBHH, Kandasamy J
    Data Brief, 2019 Apr;23:103671.
    PMID: 30788395 DOI: 10.1016/j.dib.2019.01.019
    Newly prepared titanium alloy (Ti-13Zr-13Nb (TZN)) using powder metallurgy is considered in this investigation. Titanium alloys (TZN) are used in hip and knee replacement for orthopedic implants. Conventional machining, TZN alloys produce higher tool wear rate and poor surface quality, but this can be reduced by Electrical Discharge Machining (EDM) method. Moreover, EDM produce good biological and corrosion resistant surface. In this research, experiments were conducted by considering the influential process factors such as pulse on time, pulse off time, voltage, and current. The experiments were designed based on Response Surface Methodology (RSM) of face centered central composite design. Analysis of Variance (ANOVA) was conducted to identify the significance process factors and their relation to output responses such as Electrode Wear Rate (EWR), Surface Roughness (SR) and Material Removal Rate (MRR). Further, an empirical model was developed by RSM in order to predict the output responses.
    Matched MeSH terms: Prostheses and Implants
  10. Patil PG, Nimbalkar-Patil S
    J Indian Prosthodont Soc, 2017 2 22;17(1):84-88.
    PMID: 28216851 DOI: 10.4103/0972-4052.176538
    INTRODUCTION: Maxillary obturator prosthesis is more frequent treatment modality than surgical reconstruction for maxillectomy in patients suffering from oral cancer. The obturators often become heavy and hence are hollowed out in the defect portion to reduce its weight as a standard practice.

    MATERIALS AND METHODS: The processing technique described the incorporation of the preshaped "wax-bolus" during packing procedure of the Obturtor prosthesis and eliminated later by melting it once the curing procedure is completed.

    RESULTS: This article is a single step procedure resulting into the closed-hollow obturator as single unit with uniform wall thickness around the hollow space ensuring the least possible weight of the hollow obturator.

    CONCLUSION: This processing technique achieves predictable internal dimension of the hollow space providing uniform wall thickness of the obturator.

    Matched MeSH terms: Prostheses and Implants
  11. Reza Sanaei M, Abu J, Nazari M, A B MZ, Allaudin ZN
    Vet Surg, 2013 Nov;42(8):963-70.
    PMID: 24117844 DOI: 10.1111/j.1532-950X.2013.12057.x
    To evaluate the osteogenic potential of avian demineralized bone matrix (DBM) in the context of implant geometry.
    Matched MeSH terms: Prostheses and Implants/standards; Prostheses and Implants/veterinary*
  12. Leung PC
    Med J Malaysia, 1986 Sep;41(3):260-3.
    PMID: 3312975
    When referring to amputation, the immediate association tends to be amputation related to trauma. There is little doubt that injury is by far the commonest cause of amputation, but one must not forget that babies might also be born with amputations of the upper limb. This latter group of amelia composes the various types of congenital amputations.
    Matched MeSH terms: Prostheses and Implants
  13. Singh VA, Heng CW, Yasin NF
    Indian J Orthop, 2018 2 9;52(1):65-72.
    PMID: 29416172 DOI: 10.4103/ortho.IJOrtho_188_17
    Background: Limb salvage surgery with endoprosthesis for bone tumor around the knee is reported to have good functional and oncological outcomes. However, the functional assessment using musculoskeletal tumor society (MSTS) and Toronto extremity scoring system remains subjective. We performed gait analysis as an objective assessment of their functional outcome.

    Materials and Methods: Gait analysis was performed in 20 patients with endoprosthesis replacement around the knee. The temporal parameters assessed during gait analysis were walking velocity, stride length, duration of stance, and goniometry of the knee. These parameters were compared with the functional outcome score of the MSTS.

    Results: The mean free-paced walking velocity was 0.91 m/s (normal is 1.33 m/s), which was 68% lower than normal gait. The stride length and stance phase were shorter for the affected limb compared to normal (P < 0.05). However, the gait was symmetrical with no difference in stride length (P = 0.148), velocity (P = 0.918), knee flexion (P = 0.465), and knee extension (P = 0.321) between the affected and unaffected limbs. Sixteen patients demonstrated stiff knee gait, two had a flexed knee gait, and only two patients had normal gait during the stance phase. The mean MSTS score was 21. There was significant correlation between overall MSTS scores (P = 0.023), function (P = 0.039), and walking scores (P = 0.007).

    Conclusion: Limb salvage surgery with endoprosthesis reconstruction around the knee gives good functional outcome, both objectively and subjectively, as evidenced by the symmetrical gait pattern and significant correlation with MSTS score. Despite decreased walking velocity, stride length, and stance phase of the operated limb, the patient still has a symmetrical gait.

    Matched MeSH terms: Prostheses and Implants
  14. Sia U, Tan BB, Teo YY, Wong CC
    Malays Orthop J, 2019 Mar;13(1):14-19.
    PMID: 31001378 DOI: 10.5704/MOJ.1903.002
    Introduction: Post-implantation rod deformation is anticipated in scoliosis surgery but the difference in rod deformation between titanium and cobalt chrome rod has not been elucidated. This study aims to compare the difference in rod deformation between two groups. Materials and Methods: Twenty-one adolescent idiopathic scoliosis (AIS) patients were recruited from a single center. The over-contoured concave rods were traced prior to insertion. Post-operative sagittal rod shape was determined from lateral radiographs. Rod deformation was determined using maximal rod deflection and angle of the tangents to rod end points. The differences between pre- and post-operative rod contour were analysed statistically. Rod deformation and thoracic kyphosis between two types of implants were analysed. Results: Both rods exhibited significant change of rod angle and deflection post-operatively. Curvature of the titanium rod and cobalt chrome rod decreased from 60.5° to 37°, and 51° to 28° respectively. Deflection of titanium rod and cobalt chrome rod reduced from 28mm to 23.5mm and 30mm to 17mm respectively. There was no significant difference between titanium and cobalt chrome groups with regard to rod angle (p=0.173) and deflection (p=0.654). Thoracic kyphosis was increased from 20° to 26° in titanium group but a reduction from 25° to 23° was noticed in cobalt chrome group, but these findings were not statistically significant. Conclusion: There was no statistical difference in rod deformation between the two groups. Thus, the use of titanium rod in correction of sagittal profile is not inferior in outcome compared with cobalt chrome but with lower cost.
    Matched MeSH terms: Prostheses and Implants
  15. Farook TH, Abdullah JY, Jamayet NB, Alam MK
    J Prosthet Dent, 2021 Feb 15.
    PMID: 33602541 DOI: 10.1016/j.prosdent.2020.07.039
    STATEMENT OF PROBLEM: Computer-aided design (CAD) of maxillofacial prostheses is a hardware-intensive process. The greater the mesh detail is, the more processing power is required from the computer. A reduction in mesh quality has been shown to reduce workload on computers, yet no reference value of reduction is present for intraoral prostheses that can be applied during the design.

    PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.

    MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.

    RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (P

    Matched MeSH terms: Prostheses and Implants
  16. Hawa Ismail, Ng, S.K., Hing, H.L., Normalawati Shamsudin, Ridzwan Hashim
    MyJurnal
    The calcareous rings of two species of local sea cucumbers, Stichopus hermanni Semper and Holothuria atra Jaeger, were located, dissected, exposed and recorded. The calcareous rings of both species each composed of ten plates knit together by connective tissues. The radial plate of H. atra was a square with a notch at the anterior part whereas in S. hermanni it was squarish consisting of 4 ridges in the anterior part with a notch at the posterior part. The interradial plates of both species were smaller than the radial plates. A ridge was present at the anterior part of the interradial plate in H. atra. In S. hermanii, the ridge at the anterior part of the interradial was thin and prominent. Under the scanning electron microscope the calcareous rings from the two species exhibited a mosaic of small, numerous spicules bound to each other.
    Matched MeSH terms: Prostheses and Implants
  17. Htun, T.H., Dublin, N., Parameswaran, M., Razack, A.H., Chua, C.B.
    JUMMEC, 2008;11(1):27-29.
    MyJurnal
    Priapism is a urological emergency. The treatment for ischaemic priapism is usually cavernosal aspiration with or without cavernosal irrigation. Some patients may need surgical intervention -the various shunt procedures. We report a 21-year-old man with priapism secondary to chronic myeloid leukemia who needed a combined medical and surgical management. He underwent a spongiocavernosal shunt as well as cytoreductive chemotherapy to achieve complete detumescence. Therefore, cytoreductive chemotherapy is an adjunct in difficult cult to treat priapism associated with chronic myeloid leukemia.
    Matched MeSH terms: Prostheses and Implants
  18. Asri RIM, Harun WSW, Samykano M, Lah NAC, Ghani SAC, Tarlochan F, et al.
    Mater Sci Eng C Mater Biol Appl, 2017 Aug 01;77:1261-1274.
    PMID: 28532004 DOI: 10.1016/j.msec.2017.04.102
    Corrosion prevention in biomaterials has become crucial particularly to overcome inflammation and allergic reactions caused by the biomaterials' implants towards the human body. When these metal implants contacted with fluidic environments such as bloodstream and tissue of the body, most of them became mutually highly antagonistic and subsequently promotes corrosion. Biocompatible implants are typically made up of metallic, ceramic, composite and polymers. The present paper specifically focuses on biocompatible metals which favorably used as implants such as 316L stainless steel, cobalt-chromium-molybdenum, pure titanium and titanium-based alloys. This article also takes a close look at the effect of corrosion towards the implant and human body and the mechanism to improve it. Due to this corrosion delinquent, several surface modification techniques have been used to improve the corrosion behavior of biocompatible metals such as deposition of the coating, development of passivation oxide layer and ion beam surface modification. Apart from that, surface texturing methods such as plasma spraying, chemical etching, blasting, electropolishing, and laser treatment which used to improve corrosion behavior are also discussed in detail. Introduction of surface modifications to biocompatible metals is considered as a "best solution" so far to enhanced corrosion resistance performance; besides achieving superior biocompatibility and promoting osseointegration of biocompatible metals and alloys.
    Matched MeSH terms: Prostheses and Implants
  19. Ho W, Lin Seow L, Musawi A
    J Clin Transl Res, 2018 May 28;4(1):70-74.
    PMID: 30873496
    Background: The purpose of the present study was to investigate the effect of different viscosities of polyvinyl siloxane (PVS) impression materials on the accuracy of the stone die produced.

    Methods: A three-unit bridge master model was fabricated using cold-cure acrylic resin. Four combinations of different viscosities of PVS impression materials - regular body (monophase) alone, light body with regular body, light body with heavy body, and light body with putty - were used to make an impression of the master model. Ten impressions from each group were taken and Type IV gypsum stone was used to generate the dies. The dies were measured at the inter-abutment distance, occlusogingival length, and shoulder width with a measuring microscope and were compared with the master model using one-way analysis of variance and Tukey (honest significant difference) test.

    Results: Differences were found for inter-abutment distance between the master model and the light body with regular body and light body with putty dies (both P < 0.02). A difference was found for shoulder width between the master model and the regular body alone die (P = 0.01). No differences were found for occlusogingival distance (all P > 0.08).

    Conclusion: Results suggested inter-abutment distance was most accurate when using a PVS light body combination. Occlusogingival length was accurate using any of the studied PVS combinations, and shoulder width was more accurate when using the regular body PVS.

    Relevance for patients: These results should be considered when choosing the viscosity of the PVS to use for producing impressions of high accuracy and fabricating a well-fitting fixed prosthesis.

    Matched MeSH terms: Prostheses and Implants
  20. Mohanadas HP, Nair V, Doctor AA, Faudzi AAM, Tucker N, Ismail AF, et al.
    Ann Biomed Eng, 2023 Nov;51(11):2365-2383.
    PMID: 37466879 DOI: 10.1007/s10439-023-03322-x
    Additive Manufacturing is noted for ease of product customization and short production run cost-effectiveness. As our global population approaches 8 billion, additive manufacturing has a future in maintaining and improving average human life expectancy for the same reasons that it has advantaged general manufacturing. In recent years, additive manufacturing has been applied to tissue engineering, regenerative medicine, and drug delivery. Additive Manufacturing combined with tissue engineering and biocompatibility studies offers future opportunities for various complex cardiovascular implants and surgeries. This paper is a comprehensive overview of current technological advancements in additive manufacturing with potential for cardiovascular application. The current limitations and prospects of the technology for cardiovascular applications are explored and evaluated.
    Matched MeSH terms: Prostheses and Implants
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links