Developing tools to assist physically disabled and immobilized people through facial expression is a challenging area of research and has attracted many researchers recently. In this paper, luminance stickers based facial expression recognition is proposed. Recognition of facial expression is carried out by employing Discrete Wavelet Transform (DWT) as a feature extraction method. Different wavelet families with their different orders (db1 to db20, Coif1 to Coif 5 and Sym2 to Sym8) are utilized to investigate their performance in recognizing facial expression and to evaluate their computational time. Standard deviation is computed for the coefficients of first level of wavelet decomposition for every order of wavelet family. This standard deviation is used to form a set of feature vectors for classification. In this study, conventional validation and cross validation are performed to evaluate the efficiency of the suggested feature vectors. Three different classifiers namely Artificial Neural Network (ANN), k-Nearest Neighborhood (kNN) and Linear Discriminant Analysis (LDA) are used to classify a set of eight facial expressions. The experimental results demonstrate that the proposed method gives very promising classification accuracies.
The goal of this paper is to discuss and compare three feature extraction methods: Linear Predictive Coefficients (LPC), Linear Prediction Cepstral Coefficients (LPCC) and Weighted Linear Prediction Cepstral Coefficients (WLPCC) for recognizing the stuttered events. Speech samples from the University College London Archive of Stuttered Speech (UCLASS) were used for our analysis. The stuttered events were identified through manual segmentation and were used for feature extraction. Two simple classifiers namely, k-nearest neighbour (kNN) and Linear Discriminant Analysis (LDA) were employed for speech dysfluencies classification. Conventional validation method was used for testing the reliability of the classifier results. The study on the effect of different frame length, percentage of overlapping, value of ã in a first order pre-emphasizer and different order p were discussed. The speech dysfluencies classification accuracy was found to be improved by applying statistical normalization before feature extraction. The experimental investigation elucidated LPC, LPCC and WLPCC features can be used for identifying the stuttered events and WLPCC features slightly outperforms LPCC features and LPC features.
Content-based image retrieval techniques have been extensively studied for the past few years. With the growth of digital medical image databases, the demand for content-based analysis and retrieval tools has been increasing remarkably. Blood cell image is a key diagnostic tool for hematologists. An automated system that can retrieved relevant blood cell images correctly and efficiently would save the effort and time of hematologists. The purpose of this work is to develop such a content-based image retrieval system. Global color histogram and wavelet-based methods are used in the prototype. The system allows users to search by providing a query image and select one of four implemented methods. The obtained results demonstrate the proposed extended query refinement has the potential to capture a user's high level query and perception subjectivity by dynamically giving better query combinations. Color-based methods performed better than wavelet-based methods with regard to precision, recall rate and retrieval time. Shape and density of blood cells are suggested as measurements for future improvement. The system developed is useful for undergraduate education.
Studies related to healthcare ICT integration in Malaysia are relatively little, thus this paper provide a literature review of the integration of information and communication technologies (ICT) in the healthcare sector in Malaysia through the hospital information system (HIS). Our study emphasized on secondary data to investigate the factors related to ICT integration in healthcare through HIS. Therefore this paper aimed to gather an in depth understanding of issues related to HIS adoption, and contributing in fostering HIS adoption in Malaysia and other countries. This paper provides a direction for future research to study the correlation of factors affecting HIS adoption. Finally a research model is proposed using current adoption theories and external factors from human, technology, and organization perspectives.
This paper presents a new approach to detect exudates and optic disc from color fundus images based on inverse surface thresholding. The strategy involves the applications of fuzzy c-means clustering, edge detection, otsu thresholding and inverse surface thresholding. The main advantage of the proposed approach is that it does not depend on manually selected parameters that are normally chosen to suit the tested databases. When applied to two sets of databases the proposed method outperforms a method based on watershed segmentation.
Acoustic analysis of infant cry signals has been proven to be an excellent tool in the area of automatic detection of pathological status of an infant. This paper investigates the application of parameter weighting for linear prediction cepstral coefficients (LPCCs) to provide the robust representation of infant cry signals. Three classes of infant cry signals were considered such as normal cry signals, cry signals from deaf babies and babies with asphyxia. A Probabilistic Neural Network (PNN) is suggested to classify the infant cry signals into normal and pathological cries. PNN is trained with different spread factor or smoothing parameter to obtain better classification accuracy. The experimental results demonstrate that the suggested features and classification algorithms give very promising classification accuracy of above 98% and it expounds that the suggested method can be used to help medical professionals for diagnosing pathological status of an infant from cry signals.
With the dramatic increase of the worldwide threat of dengue disease, it has been very crucial to correctly diagnose the dengue patients in order to decrease the disease severity. However, it has been a great challenge for the physicians to identify the level of risk in dengue patients due to overlapping of the medical classification criteria. Therefore, this study aims to construct a noninvasive diagnostic system to assist the physicians for classifying the risk in dengue patients. Systematic producers have been followed to develop the system. Firstly, the assessment of the significant predictors associated with the level of risk in dengue patients was carried out utilizing the statistical analyses technique. Secondly, Multilayer perceptron neural network models trained via Levenberg-Marquardt and Scaled Conjugate Gradient algorithms was employed for constructing the diagnostic system. Finally, precise tuning for the models' parameters was conducted in order to achieve the optimal performance. As a result, 9 noninvasive predictors were found to be significantly associated with the level of risk in dengue patients. By employing those predictors, 75% prediction accuracy has been achieved for classifying the risk in dengue patients using Scaled Conjugate Gradient algorithm while 70.7% prediction accuracy were achieved by using Levenberg-Marquardt algorithm.
The increasing number of diabetic retinopathy (DR) cases world wide demands the development of an automated decision support system for quick and cost-effective screening of DR. We present an automatic screening system for detecting the early stage of DR, which is known as non-proliferative diabetic retinopathy (NPDR). The proposed system involves processing of fundus images for extraction of abnormal signs, such as hard exudates, cotton wool spots, and large plaque of hard exudates. A rule based classifier is used for classifying the DR into two classes, namely, normal and abnormal. The abnormal NPDR is further classified into three levels, namely, mild, moderate, and severe. To evaluate the performance of the proposed decision support framework, the algorithms have been tested on the images of STARE database. The results obtained from this study show that the proposed system can detect the bright lesions with an average accuracy of about 97%. The study further shows promising results in classifying the bright lesions correctly according to NPDR severity levels.
Due to increasing number of diabetic retinopathy cases, ophthalmologists are experiencing serious problem to automatically extract the features from the retinal images. Optic disc (OD), exudates, and cotton wool spots are the main features of fundus images which are used for diagnosing eye diseases, such as diabetic retinopathy and glaucoma. In this paper, a new algorithm for the extraction of these bright objects from fundus images based on marker-controlled watershed segmentation is presented. The proposed algorithm makes use of average filtering and contrast adjustment as preprocessing steps. The concept of the markers is used to modify the gradient before the watershed transformation is applied. The performance of the proposed algorithm is evaluated using the test images of STARE and DRIVE databases. It is shown that the proposed method can yield an average sensitivity value of about 95%, which is comparable to those obtained by the known methods.
This paper aims at identifying the factors that would help to diagnose acute myocardial infarction (AMI) using data from an electronic medical record system (EMR) and then generating structure decisions in the form of linguistic fuzzy rules to help predict and understand the outcome of the diagnosis. Since there is a tradeoff in the fuzzy system between the accuracy which measures the capability of the system to predict the diagnosis of AMI and transparency which reflects its ability to describe the symptoms-diagnosis relation in an understandable way, the proposed fuzzy rules are designed in a such a way to find an appropriate balance between these two conflicting modeling objectives using multi-objective genetic algorithms. The main advantage of the generated linguistic fuzzy rules is their ability to describe the relation between the symptoms and the outcome of the diagnosis in an understandable way, close to human thinking and this feature may help doctors to understand the decision process of the fuzzy rules.
Current trends in medicine, specifically in the electronic handling of medical applications, ranging from digital imaging, paperless hospital administration and electronic medical records, telemedicine, to computer-aided diagnosis, creates a burden on the network. Distributed Service Architectures, such as Intelligent Network (IN), Telecommunication Information Networking Architecture (TINA) and Open Service Access (OSA), are able to meet this new challenge. Distribution enables computational tasks to be spread among multiple processors; hence, performance is an important issue. This paper proposes a novel approach in load balancing, the Random Sender Initiated Algorithm, for distribution of tasks among several nodes sharing the same computational object (CO) instances in Distributed Service Architectures. Simulations illustrate that the proposed algorithm produces better network performance than the benchmark load balancing algorithms-the Random Node Selection Algorithm and the Shortest Queue Algorithm, especially under medium and heavily loaded conditions.
A novel technique to quantify the signal-to-noise ratio (SNR) of magnetic resonance images is developed. The image SNR is quantified by estimating the amplitude of the signal spectrum using the autocorrelation function of just one single magnetic resonance image. To test the performance of the quantification, SNR measurement data are fitted to theoretically expected curves. It is shown that the technique can be implemented in a highly efficient way for the magnetic resonance imaging system.
This paper presents the results obtained for medical image compression using autoencoder neural networks. Since mammograms (medical images) are usually of big sizes, training of autoencoders becomes extremely tedious and difficult if the whole image is used for training. We show in this paper that the autoencoders can be trained successfully by using image patches instead of the whole image. The compression performances of different types of autoencoders are compared based on two parameters, namely mean square error and structural similarity index. It is found from the experimental results that the autoencoder which does not use Restricted Boltzmann Machine pre-training yields better results than those which use this pre-training method.
An important preliminary step in the diagnosis of leukemia is the visual examination of the patient's peripheral blood smear under the microscope. Morphological changes in the white blood cells can be an indicator of the nature and severity of the disease. Manual techniques are labor intensive, slow, error prone and costly. A computerized system can be used as a supportive tool for the specialist in order to enhance and accelerate the morphological analysis process. This research present a new method that integrates color features with the morphological reconstruction to localize and isolate lymphoblast cells from a microscope image that contains many cells. The localization and segmentation are conducted using a proposed method that consists of an integration of several digital image processing techniques. 180 microscopic blood images were tested, and the proposed framework managed to obtain 100% accuracy for the localization of the lymphoblast cells and separate it from the image scene. The results obtained indicate that the proposed method can be safely used for the purpose of lymphoblast cells localization and segmentation and subsequently, aiding the diagnosis of leukemia.
The next generation of medical information system will integrate multimedia data to assist physicians in clinical decision-making, diagnoses, teaching, and research. This paper describes MIARS (Medical Image Annotation and Retrieval System). MIARS not only provides automatic annotation, but also supports text based as well as image based retrieval strategies, which play important roles in medical training, research, and diagnostics. The system utilizes three trained classifiers, which are trained using training images. The goal of these classifiers is to provide multi-level automatic annotation. Another main purpose of the MIARS system is to study image semantic retrieval strategy by which images can be retrieved according to different levels of annotation.
The detection of bright objects such as optic disc (OD) and exudates in color fundus images is an important step in the diagnosis of eye diseases such as diabetic retinopathy and glaucoma. In this paper, a novel approach to automatically segment the OD and exudates is proposed. The proposed algorithm makes use of the green component of the image and preprocessing steps such as average filtering, contrast adjustment, and thresholding. The other processing techniques used are morphological opening, extended maxima operator, minima imposition, and watershed transformation. The proposed algorithm is evaluated using the test images of STARE and DRIVE databases with fixed and variable thresholds. The images drawn by human expert are taken as the reference images. The proposed method yields sensitivity values as high as 96.7%, which are better than the results reported in the literature.
Service architectures are necessary for providing value-added services in telecommunications networks, including those in medical institutions. Separation of service logic and control from the actual call switching is the main idea of these service architectures, examples include Intelligent Network (IN), Telecommunications Information Network Architectures (TINA), and Open Service Access (OSA). In the Distributed Service Architectures (DSA), instances of the same object type can be placed on different physical nodes. Hence, the network performance can be enhanced by introducing load balancing algorithms to efficiently distribute the traffic between object instances, such that the overall throughput and network performance can be optimised. In this paper, we propose a new load balancing algorithm called "Node Status Algorithm" for DSA infrastructure applicable to electronic-based medical institutions. The simulation results illustrate that this proposed algorithm is able to outperform the benchmark load balancing algorithms-Random Algorithm and Shortest Queue Algorithm, especially under medium and heavily loaded network conditions, which are typical of the increasing bandwidth utilization and processing requirements at paperless hospitals and in the telemedicine environment.
This work presents a method for liver isolation in magnetic resonance imaging (MRI) abdomen images. It is based on a priori statistical information about the shape of the liver obtained from a training set using the segmentation approach. Morphological watershed algorithm is used as a key technique as it is a simple and intuitive method, producing a complete division of the image in separated regions even if the contrast is poor, and it is fast, with possibility for parallel implementation. To overcome the over-segmentation problem of the watershed process, image preprocessing and postprocessing are applied. Morphological smoothing, Gaussian smoothing, intensity thresholding, gradient computation and gradient thresholding are proposed for preprocessing with morphological and graph based region adjacent list constructed for region merging. A new integrated region similarity function is also defined for region merging control. The proposed method produces good isolation of liver in axial MRI images of the abdomen, as is shown in this paper.
Blood vessel detection in retinal images is a fundamental step for feature extraction and interpretation of image content. This paper proposes a novel computational paradigm for detection of blood vessels in fundus images based on RGB components and quadtree decomposition. The proposed algorithm employs median filtering, quadtree decomposition, post filtration of detected edges, and morphological reconstruction on retinal images. The application of preprocessing algorithm helps in enhancing the image to make it better fit for the subsequent analysis and it is a vital phase before decomposing the image. Quadtree decomposition provides information on the different types of blocks and intensities of the pixels within the blocks. The post filtration and morphological reconstruction assist in filling the edges of the blood vessels and removing the false alarms and unwanted objects from the background, while restoring the original shape of the connected vessels. The proposed method which makes use of the three color components (RGB) is tested on various images of publicly available database. The results are compared with those obtained by other known methods as well as with the results obtained by using the proposed method with the green color component only. It is shown that the proposed method can yield true positive fraction values as high as 0.77, which are comparable to or somewhat higher than the results obtained by other known methods. It is also shown that the effect of noise can be reduced if the proposed method is implemented using only the green color component.
Monitoring the depth of anesthesia (DOA) during surgery is very important in order to avoid patients' interoperative awareness. Since the traditional methods of assessing DOA which involve monitoring the heart rate, pupil size, sweating etc, may vary from patient to patient depending on the type of surgery and the type of drug administered, modern methods based on electroencephalogram (EEG) are preferred. EEG being a nonlinear signal, it is appropriate to use nonlinear chaotic parameters to identify the anesthetic depth levels. This paper discusses an automated detection method of anesthetic depth levels based on EEG recordings using non-linear chaotic features and neural network classifiers. Three nonlinear parameters, namely, correlation dimension (CD), Lyapunov exponent (LE) and Hurst exponent (HE) are used as features and two neural network models, namely, multi-layer perceptron network (feed forward model) and Elman network (feedback model) are used for classification. The neural network models are trained and tested with single and multiple features derived from chaotic parameters and the performances are evaluated in terms of sensitivity, specificity and overall accuracy. It is found from the experimental results that the Lyapunov exponent feature with Elman network yields an overall accuracy of 99% in detecting the anesthetic depth levels.