Sera from one hundred and fifty nine Malaysian individuals were screened for the prevalence of delta markers. These included 15 HBsAg positive homosexuals, 16 acute hepatitis B cases, 9 chronic hepatitis B patients, 13 healthy HBsAg carriers and 106 intravenous (i.v.) drug abusers, of whom 27 were positive for HBsAg only and the rest were anti-HBc IgG positive but HBsAg negative. The prevalence of delta markers in the homosexuals was found to be 6.7%, in the HBsAg positive drug abusers 17.8%, in acute hepatitis B cases 12.5%. No evidence of delta infection was detected in healthy HBsAg carriers, chronic hepatitis B cases and HBsAg negative i.v. drug abusers. With reference to i.v. drug abusers, the prevalence of delta markers was higher in Malays (23%) than in Chinese (7%) although the latter had a higher HBsAg carrier rate. Although the HBsAg carrier rate in the homosexuals was high, their delta prevalence rate was low as compared to drug abusers. In Malaysia, as in other non-endemic regions, hepatitis delta virus transmission appeared to occur mainly via the parenteral and sexual routes. This is the first time in Malaysia that a reservoir of delta infection has been demonstrated in certain groups of the population at high risk for hepatitis B.
Matched MeSH terms: Hepatitis Antibodies/analysis; Hepatitis B Antibodies/analysis
Several critical factors of an influenza microneutralization assay, utilizing a rapid biotin-streptavidin conjugated system for detecting influenza virus subtypes A and B, are addressed within this manuscript. Factors such as incubation times, amount of virus, cell seeding, sonication, and TPCK trypsin were evaluated for their ability to affect influenza virus neutralization in a microplate-based neutralization assay using Madin-Darby canine kidney (MDCK) cells. It is apparent that the amount of virus used in the assay is the most critical factor to be optimized in an influenza microneutralization assay. Results indicate that 100xTCID(50) of influenza A/Solomon Islands/03/2006 (H1N1) virus overloads the assay and results in no, to low, neutralization, in both ferret and macaque sera, respectively, whereas using 6xTCID(50) resulted in significantly improved neutralization. Conversely, strong neutralization was observed against 100xTCID(50) of B/Malaysia/2506/04 virus. In this manuscript the critical factors described above were optimized and the results indicate that the described biotin-streptavidin conjugated influenza microneutralization assay is a rapid and robust method for detecting the presence of functional, influenza virus-neutralizing antibodies.
Toxoplasma gondii, an obligate intracellular protozoan parasite, causes a disease called toxoplasmosis which can sometimes be acquired congenitally by a newborn from an infected mother. This study aimed to determine the seroprevalence of Toxoplasma infection and its associated risks among 219 and 215 pregnant women from Malaysia and Myanmar, respectively.
Leptospirosis is a zoonotic disease caused by Leptospira species and is distributed globally. Microscopic agglutination test (MAT) is the serological 'gold standard' for diagnosis of leptospirosis but it is time-consuming and labour-intensive. An alternative serological method that is rapid, sensitive and specific is important for early treatment to reduce morbidity and mortality. The use of local Leptospira isolation may improve the sensitivity and specificity of the test because it may varies from one geographical region to another region. The objective of this study was to determine the sensitivity, specificity and cut-off points for an in-house Immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) using a locally isolated Leptospiral strain IMR/175 as the antigen for the detection of anti-Leptospiral IgM.
Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60-75% and specificity 71-80%; NS1 RDT sensitivity was 38-71% and specificity 76-80%; the IgM anti-DENV RDTs sensitivity was 30-96%, with a specificity of 86-92%, and IgM anti-DENV ELISA sensitivity was 96-98% and specificity 78-91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88-94%.
The application of antibodies in enzyme-linked immunosorbent assay (ELISA) is the basis of this diagnostic technique which is designed to detect a potpourri of complex target molecules such as cell surface antigens, allergens, and food contaminants. However, development of the systematic evolution of Ligands by Exponential Enrichment (SELEX) method, which can generate a nucleic acid-based probe (aptamer) that possess numerous advantages compared to antibodies, offers the possibility of using aptamers as an alternative molecular recognition element in ELISA. Compared to antibodies, aptamers are smaller in size, can be easily modified, are cheaper to produce, and can be generated against a wide array of target molecules. The application of aptamers in ELISA gives rise to an ELISA-derived assay called enzyme-linked apta-sorbent assay (ELASA). As with the ELISA method, ELASA can be used in several different configurations, including direct, indirect, and sandwich assays. This review provides an overview of the strategies involved in aptamer-based ELASA.
Nipah virus and Hendra virus are closely related and following natural or experimental exposure induce similar clinical disease. In humans, encephalitis is the most serious outcome of infection and, hitherto, research into the pathogenesis of henipavirus encephalitis has been limited by the lack of a suitable model. Recently we reported a wild-type mouse model of Hendra virus (HeV) encephalitis that should facilitate detailed investigations of its neuropathogenesis, including mechanisms of disease recrudescence. In this study we investigated the possibility of developing a similar model of Nipah virus encephalitis.
We performed a cross-sectional study of all antiphospholipid syndrome (APS) patients during an 8-year period (2006-2013) to describe the clinical features, serology profiles, treatment regimes, and outcomes in our center. There were a total of 59 patients in our study with the female to male ratio of 9:1. They have a mean age of 41.6 ± 12.1 years and a mean duration of illness of 38.4 ± 68.5 months. The majority of patients presented with vascular thrombosis (69.5 %) with equal arterial and venous involvements. Twenty-six patients (44.1 %) presented with obstetric complications with recurrent abortions (32.2 %) as the main manifestation. Most patients were on daily warfarin doses of 2-6 mg (91.0 %) with target INR of 2-3. There was neither recurrent thrombosis nor bleeding complications documented. There were 80 % live births following treatment in our patients.
Dengue represents one of the most serious life-threatening vector-borne infectious diseases that afflicts approximately 50 million people across the globe annually. Whilst symptomatic infections are frequently reported, asymptomatic dengue remains largely unnoticed. Therefore, we sought to investigate the immune correlates conferring protection to individuals that remain clinically asymptomatic.
Snake envenomation is a serious public health threat in many rural areas of Asia and Africa. Antivenom has hitherto been the definite treatment for snake envenomation. Owing to a lack of local production of specific antivenom, most countries in these regions fully depend on foreign supplies of antivenoms. Often, the effectiveness of the imported antivenoms against local medically important species has not been validated. This study aimed to assess cross-neutralizing capacity of a recently developed polyvalent antivenom, Hemato Polyvalent Snake Antivenom (HPAV), against venoms of a common viper and some pit vipers from Southeast Asia. Neutralisation assays showed that HPAV was able to effectively neutralize lethality of the common Southeast Asian viperid venoms examined (Calloselasma, Crytelytrops, Popeia, and Daboia sp.) except for Tropidolaemus wagleri venom. HPAV also effectively neutralized the procoagulant and hemorrhagic activities of all the venoms examined, corroboratively supporting the capability of HPAV in neutralizing viperid venoms which are principally hematoxic. The study also indicated that HPAV fully prevented the occurrence of hematuria and proteinuria in mice envenomed with Thai Daboia siamensis venom but was only partially effective against venoms of Myanmar D. siamensis. Thus, HPAV appears to be useful against its homologous venoms and venoms from Southeast Asian viperids including several medically important pit vipers belonging to the Trimeresurus complex. Nevertheless, the effectiveness of HPAV as a paraspecific antivenom for treatment of viperid envenomation in Southeast Asian region requires further assessment from future clinical trials.
To address immunocapture of proteins in large cohorts of clinical samples high throughput sample processing is required. Here a method using the proteomic sample platform, ISET (integrated selective enrichment target) that integrates highly specific immunoaffinity capture of protein biomarker, digestion and sample cleanup with a direct interface to mass spectrometry is presented. The robustness of the on-ISET protein digestion protocol was validated by MALDI MS analysis of model proteins, ranging from 40 fmol to 1 pmol per nanovial. On-ISET digestion and MALDI MS/MS analysis of immunoaffinity captured disease-associated biomarker PSA (prostate specific antigen) from human seminal plasma are presented.
Uncontrolled hypertension is well- known to give rise to systemic complications involving multiple central organs. Artherosclerosis leads to damage of the retinal vessels wall, contributing to venous stasis, thrombosis and finally, occlusion. Retinal vein occlusions compromise vision through development of ischaemic maculopathy, macular oedema, and rubeotic glaucoma. Laser photocoagulation remains the definitive treatment for ischaemic vein occlusion with secondary neovascularization. Timely treatment with anti- vascular endothelial growth factor prevents development of rubeotic glaucoma. We hereby report an unusual case of bilateral retinal vein occlusion complicated by rubeosis irides, which was successfully managed to improve vision and prevent rubeotic glaucoma.
Matched MeSH terms: Antibodies, Monoclonal, Humanized/therapeutic use
The presence of antiphospholipid antibodies (aPLs) is closely associated with thrombotic events and pregnancy complications such as recurrent pregnancy loss, preeclampsia and placental insufficiency. We investigated the presence of aPLs and its frequency among female patients with a history of fetal loss in a Malaysia population. Serum samples were collected from 108 patients who had (1) one or more unexplained deaths of morphologically normal fetuses at or beyond the 22nd week of gestation, or (2) one or more premature births of morphologically normal neonates at or before the 24th week of gestation due to eclampsia or preeclampsia, or recognized features of placental insufficiency, or (3) three or more unexplained, consecutive, spontaneous miscarriages before the 20th week of gestation. Serum was tested for aPLs subtypes: anticardiolipin (aCL), anti-beta-2- glycoprotein I (aβ2GPI), anti-beta-2-glycoprotein I dependent cardiolipin (aβ2GPI dependent CL), anti-phosphatidylcholine (aPC), anti-phosphatidylethanolamine (aPE), anti-phosphatidylinositol (aPI), anti-phosphatidylserine (aPS) and anti-sphingomyeline (aSph) by using the enzyme-linked immunosorbent assay (ELISA) method. The mean age of patients was 30±5. Four patients (3.7%) were found positive for at least one aPLs subtype. Four aPLs subtypes were detected. The most common subtypes was aβ2GPI dependent CL (3.7%), followed by aCL (2.7%), aβ2GPI (0.9%), and aPE(0.9%). In conclusion, frequency of aPLs among women with fetal loss (3.7%) in Malaysia was low with subtype aβ2GPI dependent CL being the most prevalent aPLs.
In this article we present ultra-sensitive, silicon nanowire (SiNW)-based biosensor devices for the detection of disease biomarkers. An electrochemically induced functionalisation method has been employed to graft antibodies targeted against the prostate cancer risk biomarker 8-hydroxydeoxyguanosine (8-OHdG) to SiNW surfaces. The antibody-functionalised SiNW sensor has been used to detect binding of the 8-OHdG biomarker to the SiNW surface within seconds of exposure. Detection of 8-OHdG concentrations as low as 1 ng/ml (3.5 nM) has been demonstrated. The active device has been bonded to a disposable printed circuit which can be inserted into an electronic readout system as part of an integrated Point of Care (POC) diagnostic. The speed, sensitivity and ease of detection of biomarkers using SiNW sensors render them ideal for eventual POC diagnostics.
Hemophagocytic syndrome is a potentially fatal disorder. It is being increasingly reported but remained under-recognized in dengue. Most reported cases were in association with plasma leakage and shock but multi-organ impairment was also observed. We describe the time-lines of 6 cases of confirmed dengue with varying severities of hemophagocytosis. All had persistent fever, cytopenia and elevated transaminases with markedly elevated ferritin levels during and beyond the plasma leakage phase. Acute renal failure and central nervous system manifestation were observed in two patients. Morphological hemophagocytosis was demonstrated in three patients. All survivors showed clinical and biochemical resolution of hemophagocytosis indicating its transient nature. Persistence of fever and cytopenia together with multi-organ dysfunction, out of proportion to and beyond the plasma leakage phase should prompt clinicians to consider this phenomenon.
This study aimed to describe the transmission dynamics, the serological and virus excretion patterns of Nipah virus (NiV) in Pteropus vampyrus bats. Bats in captivity were sampled every 7-21 days over a 1-year period. The data revealed five NiV serological patterns categorized as high and low positives, waning, decreasing and increasing, and negative in these individuals. The findings strongly suggest that NiV circulates in wild bat populations and that antibody could be maintained for long periods. The study also found that pup and juvenile bats from seropositive dams tested seropositive, indicating that maternal antibodies against NiV are transmitted passively, and in this study population may last up to 14 months. NiV was isolated from the urine of one bat, and within a few weeks, two other seronegative bats seroconverted. Based on the temporal cluster of seroconversion, we strongly believe that the NiV isolated was recrudesced and then transmitted horizontally between bats during the study period.
An adult Malaysian woman returned to Japan from Kuala Lumpur and had onset of dengue fever-like symptoms including high fever, malaise and arthritis in early January 2009. Serum obtained on the following day was tested at the National Institute of Infectious Diseases in Tokyo, where it was determined to be positive for chikungunya virus (CHIKV) RNA. IgM antibody against CHIKV was negative on January 6 and sero-converted to be positive on January 14, confirming a recent CHIKV infection. Except for arthralgia, all her symptoms resolved uneventfully within 10 days.