MATERIALS AND METHODS: A review of multiple reports and kit inserts on the diagnostic performance of rapid tests from various manufacturers that are commercially available were performed. Only preliminary data are available currently.
RESULTS: From a total of nine rapid detection test (RDT) kits, three kits offer total antibody detection, while six kits offer combination SARS-CoV-2 IgM and IgG detection in two separate test lines. All kits are based on colloidal gold-labeled immunochromatography principle and one-step method with results obtained within 15 minutes, using whole blood, serum or plasma samples. The sensitivity for both IgM and IgG tests ranges between 72.7% and 100%, while specificity ranges between 98.7% to 100%. Two immunochromatography using nasopharyngeal or throat swab for detection of COVID-19 specific antigen are also reviewed.
CONCLUSIONS: There is much to determine regarding the value of serological testing in COVID-19 diagnosis and monitoring. More comprehensive evaluations of their performance are rapidly underway. The use of serology methods requires appropriate interpretations of the results and understanding the strengths and limitations of such tests.
SETTINGS AND DESIGN: Case-control study at Rheumatology Clinic of Universiti Sains Malaysia Hospital.
SUBJECTS AND METHODS: The sera of SLE patients and HCs were tested for the presence of anti-CLIC2 and anti-HMGB1 autoantibodies using human recombinant proteins and ELISA methodologies. Other serological parameters were evaluated according to routine procedures, and patients' demographic and clinical data were obtained.
STATISTICAL ANALYSIS: Mann-Whitney U-test, Chi-square test, Fisher's exact test, and receiver operating characteristic analysis.
RESULTS: Anti-CLIC2 autoantibody levels were significantly higher in SLE patients compared to HCs (P = 0.0035), whereas anti-HMGB1 autoantibody levels were not significantly elevated (P = 0.7702). Anti-CLIC2 and anti-HMGB1 autoantibody levels were not associated with ANA pattern, anti-dsDNA, and CRP. Interestingly, SLEDAI score (≥6) was associated with anti-CLIC2 (P = 0.0046) and with anti-HMGB1 (P = 0.0091) autoantibody levels.
CONCLUSION: Our findings support the potential of using anti-CLIC2 autoantibodies as a novel biomarker for SLE patients. Both anti-CLIC2 and anti-HMGB1 autoantibody levels demonstrated potential in monitoring SLE disease activity.
MATERIALS AND METHODS: A total of 110 nasopharyngeal swabs (NPS) were collected from children aged one month to 12 years old who were admitted with ARI in UKMMC during a one-year period. The two qPCR assays were conducted in parallel.
RESULTS: Ninety-seven samples (88.2%) were positive by QIAstat-Dx RP and 86 (78.2%) by RespiFinder assay. The overall agreement on both assays was substantial (kappa value: 0.769) with excellent concordance rate of 96.95%. Using both assays, hRV/EV, INF A/H1N1 and RSV were the most common pathogens detected. Influenza A/H1N1 infection was significantly seen higher in older children (age group > 60 months old) (53.3%, p-value < 0.05). Meanwhile, RSV and hRV/EV infection were seen among below one-year-old children. Co-infections by two to four pathogens were detected in 17 (17.5%) samples by QIAstat-Dx RP and 12 (14%) samples by RespiFinder, mainly involving hRV/EV. Bacterial detection was observed only in 5 (4.5%) and 6 (5.4%) samples by QIAstat-Dx RP and RespiFinder, respectively, with Mycoplasma pneumoniae the most common detected.
CONCLUSION: The overall performance of the two qPCR assays was comparable and showed excellent agreement. Both detected various clinically important respiratory pathogens in a single test with simultaneous multiple infection detection. The use of qPCR as a routine diagnostic test can improve diagnosis and management.
METHOD: This study investigated the potential use of a combination of chemical and mechanical methods in the extraction of jute CNFs. Through this method, the jute fibers were first chemically treated using sodium hydroxide (NaOH), sodium chlorite (NaClO 2) and sulphuric acid (H 2SO 4) to remove the non-cellulosic elements followed by mechanical milling by using a planetary ball mill.
RESULTS: The shape and size of the obtained CNFs were observed under a field emission scanning electron microscope (FESEM). This study revealed that jute CNFs were successfully extracted through the combination of chemical and mechanical treatment methods where the obtained CNFs reveal themselves in smooth fibrous morphology with a diameter of 23 nm and 150-200nm in length.
CONCLUSIONS: Jute cellulose nanofibers were successfully drawn out from raw jute fibers by means of a combination of chemical and mechanical treatment. The results obtained confirmed that the chemomechanical method is an effective technique for isolating the CNFs and its potential use as reinforcement material was explained.