Displaying all 9 publications

Abstract:
Sort:
  1. Packiriswamy V, Nayak SB
    Kathmandu Univ Med J (KUMJ), 2021 2 15;18(69):99-101.
    PMID: 33582698
    Knowledge of normal as well as variant great saphenous vein is useful as it is the vein that can get varicosed; the vein that is used in bypass surgeries and the vein that is used for cannulation purpose. We observed almost complete duplication of the great saphenous vein in the left lower limb of an adult male cadaver. Both the great saphenous veins arose from the medial end of the dorsal venous arch and coursed parallel to each other throughout the limb. They united in the femoral triangle to form a short (1 inch long) common great saphenous vein. Common great saphenous vein terminated into the femoral vein. There were four communicating veins connecting the two great saphenous veins in the leg, giving the appearance of a venous ladder. Knowledge of this variation could be extremely useful in treatment of varicose veins of lower limb, in catheterizations and in various surgical procedures of the lower limb.
    Matched MeSH terms: Saphenous Vein*
  2. Ramzisham, A.R.M., Joanna, O.S.M., Talal, A.R., Shahrulakmal, S., Maskon, O., Noorfaizan, S., et al.
    MyJurnal
    A 29-year-old, smoker, diabetic, hypertensive and hypercholesterolemic man was diagnosed of having severe coronary artery disease with a critical left main stem stenosis. On-pump coronary artery bypass graft surgery (CABG) was performed using conduits from the left internal mammary artery as well as the left radial artery and right saphenous vein which were both harvested endoscopically. He was discharged after a week of uneventful recovery. This case emphasizes on the best possible management of conduits selection, intraoperative myocardial protection and the risk factors modifi cation in achieving a long term graft patency and avoiding premature cardiac related death.
    Matched MeSH terms: Saphenous Vein
  3. Anwar A, Chan KMJ, Awang Y, Ping DC
    Med J Malaysia, 2019 Oct;74(5):436-438.
    PMID: 31649223
    Anomalous Aortic Origin of a Coronary Artery (AAOCA) is a rare anomaly of the coronary artery with a considerable risk of sudden cardiac death due to ischaemia of the heart. Symptoms may include chest pain on exertion, breathlessness or dizziness. We encountered a case of a 46- year-old female who complained of exertional chest pain with a positive-stress test and subsequently diagnosed with AAOCA through CT angiography (CTA). She successfully underwent a coronary artery bypass graft (CABG) surgery using a saphenous vein graft with uneventful recovery. Right internal mammary artery (RIMA) was not used as it was flimsy and the flow was very poor.
    Matched MeSH terms: Saphenous Vein
  4. Abdullah F, Adeeb S
    Heart Surg Forum, 2003;6(3):E50-1.
    PMID: 12821439
    An alternative technique of superior vena cava obstruction bypass using bovine pericardial conduit is described. The patient in this case had recurrent bilateral thrombophlebitis and thrombosed saphenous veins. Most of the surgical techniques reported in the literature so far have described the use of polyethylene terephthalate (Dacron) graft, polytetrafluoroethylene graft, autologous pericardial patch, and spiral vein graft. The use of synthetic grafts has been plagued with high rates of thrombosis. The pathology, clinical presentation, surgical technique, and outcome are discussed.
    Matched MeSH terms: Saphenous Vein
  5. Rahman MR, Min JO, Dimon MZ
    Heart Surg Forum, 2010 Aug;13(4):E273-4.
    PMID: 20719738 DOI: 10.1532/HSF98.20101001
    Delayed ascending aortic dissection following coronary artery bypass surgery is a rare but lethal complication. We present the case of a 54-year-old man with a delayed acute Stanford A aortic dissection following an off-pump coronary artery bypass surgery in preexisting chronic type B disease. Such a case of an iatrogenic acute aortic dissection poses a significant challenge and dilemma in choosing the best technique for coronary revascularization in this group of patients. The pathophysiology and technical options are discussed.
    Matched MeSH terms: Saphenous Vein/transplantation
  6. Phang ZH, Miskon MFB, Ibrahim SB
    J Med Case Rep, 2018 Jul 18;12(1):211.
    PMID: 30016981 DOI: 10.1186/s13256-018-1751-7
    BACKGROUND: Blunt trauma causing brachial artery injury in a young patient is very rare. Cases of brachial artery injury may be associated with closed elbow dislocation or instability. Elbow dislocation may not be evident clinically and radiologically on initial presentation.

    CASE PRESENTATION: This is a case of a 37-year-old, right-hand dominant, Malay man who fell approximately 6 meters from a rambutan tree and his left arm hit the tree trunk on his way down. He was an active tobacco smoker with a 20 pack year smoking history. On clinical examination, Doppler signals over his radial and ulnar arteries were poor. He proceeded with emergency computed tomography angiogram of his left upper limb which showed non-opacification of contrast at the distal left brachial artery just before the bifurcation of the left brachial artery at his left elbow joint. Radiographs and computed tomography scan also showed undisplaced fracture of left lateral epicondyle and radial head with no evidence of elbow dislocation. He subsequently underwent left brachial to brachial artery bypass which was done using reversed saphenous vein graft and recovered well. His fractures were treated using 90 degree long posterior splint for 2 weeks and he was then allowed early range of motion of the left elbow. This patient developed left elbow dislocation 6 weeks postoperatively. Closed manipulative reduction of his left elbow resulted in incomplete reduction. The functional outcome of his left elbow was limited with a range of motion of left elbow of 0-45 degrees. However, he was not keen for surgery to stabilize his elbow joint during his last follow-up 6 months post injury.

    CONCLUSIONS: This is an uncommon case of brachial artery injury in a civilian caused by blunt trauma associated with occult elbow instability/dislocation and minor fractures around the elbow joint. The treatment of brachial artery injury with clinical evidence of distal ischemia is surgical revascularization. The possibility of elbow instability and dislocation need to be considered in all cases of brachial artery injury because early radiographs and computed tomography scans may be normal. Short-term posterior splint immobilization is not sufficient to prevent recurrent dislocations.

    Matched MeSH terms: Saphenous Vein/transplantation
  7. Shiang SW, Vendargon SJ, Hamid SRBGS
    J Coll Physicians Surg Pak, 2019 Apr;29(4):371-374.
    PMID: 30925964 DOI: 10.29271/jcpsp.2019.04.371
    OBJECTIVE: To determine the wound complications post coronary artery bypass graft surgery (CABG) by conventional vein harvest technique (CVH) and minimally invasive vein harvest technique (MIVH) in Hospital Sultanah Aminah Johor Bahru, Malaysia.

    STUDY DESIGN: Clinical audit report.

    PLACE AND DURATION OF STUDY: Hospital Sultanah Aminah Johor Bahru, Malaysia, from March 2016 to May 2017.

    METHODOLOGY: Data were collected retrospectively from all 127 patients who underwent CABG with saphenous vein grafts, either with CVH technique (n=68), or MIVH technique (n=59) performed with Vasoview system. The rate of wound dehiscence was evaluated. Patients with severe wound dehiscence that required readmission and surgical intervention were identified for further evaluation.

    RESULTS: There was total 26.8% of wound dehiscence in our study, which was not appreciably different between two groups (p=0.092). Patient with severe wound breakdown that required surgical intervention was significantly less in MIVH group (1/59, 1.7%) compared to CVH group (8/68, 11.8%, p=0.037). There was no significant difference in readmission rate between MIVH and CVH group (p=0.574).

    CONCLUSION: There is significant reduction in severity of wound dehiscence post-saphenous vein harvesting among CABG patients with MIVH technique. However, there is no statistical difference in wound dehiscence and readmission rate between MIVH and CVH technique.

    Matched MeSH terms: Saphenous Vein/transplantation*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links