Malaysia has a low deceased-donor donation rate and has not embarked on a paired kidney exchange program; therefore, ABO-incompatible and HLA-incompatible transplantation remain the main contributor to the sustainability of the national kidney transplantation (KT) program. There were 26 cases of ABO-incompatible KTs performed from 2011 to 2018 in 3 major transplant centers, namely, Hospital Kuala Lumpur, University Malaya Medical Centre, and Prince Court Medical Centre. We collected perioperative and follow-up data through June 2019. The desensitization protocol varies and is center specific: the localized Japanese protocol and Swedish protocol with a target anti-A/B isoagglutinin titer of 16 or 32 on the day of transplant. The induction and tacrolimus-based maintenance protocol was nearly identical. The median follow-up time was 62.3 months (interquartile range, 37.0-79.7). Fifteen subjects had the highest predesensitization anti-A/B titer of ≥32 (57.7%). The acute cellular rejection and antibody-mediated rejection incidence were 12.5% (3 cases) and 8.3% (2 cases), respectively. Patient, graft, and death-censored graft survival rates were 96.2%, 92.3%, and 96.0%, respectively, 1 year post-living-donor KT (LDKT) and 96.2%, 87.2%, and 90.7%, respectively, 5 years post-LDKT. Our experience shows that ABO-incompatible LDKT using a suitable desensitization technique could be a safe and feasible choice for LDKT even with varied desensitization regimens for recipients with relatively high baseline isoagglutinin titers.