Displaying all 7 publications

Abstract:
Sort:
  1. Khor HL, Liew SC, Zain JM
    J Digit Imaging, 2017 Jun;30(3):328-349.
    PMID: 28050716 DOI: 10.1007/s10278-016-9930-9
    Tampering on medical image will lead to wrong diagnosis and treatment, which is life-threatening; therefore, digital watermarking on medical image was introduced to protect medical image from tampering. Medical images are divided into region of interest (ROI) and region of non-interest (RONI). ROI is an area that has a significant impact on diagnosis, whereas RONI has less or no significance in diagnosis. This paper has proposed ROI-based tamper detection and recovery watermarking scheme (ROI-DR) that embeds ROI bit information into RONI least significant bits, which will be extracted later for authentication and recovery process. The experiment result has shown that the ROI-DR has achieved a good result in imperceptibility with peak signal-to-noise ratio (PSNR) values approximately 48 dB, it is robust against various kinds of tampering, and the tampered ROI was able to recover to its original form. Lastly, a comparative table with the previous research (TALLOR and TALLOR-RS watermarking schemes) has been derived, where these three watermarking schemes were tested under the same testing conditions and environment. The experiment result has shown that ROI-DR has achieved speed-up factors of 22.55 and 26.65 in relative to TALLOR and TALLOR-RS watermarking schemes, respectively.
    Matched MeSH terms: Ultrasonography/standards*
  2. Joseph LH, Hussain RI, Pirunsan U, Naicker AS, Htwe O, Paungmali A
    Acta Orthop Traumatol Turc, 2014;48(2):169-74.
    PMID: 24747625 DOI: 10.3944/AOTT.2014.3184
    The aim of this study was to investigate the intra- and inter-rater reliability of ultrasonography (US) to measure anterior translation of the humeral head (ATHH) among healthy subjects and patients with sacroiliac joint dysfunction.
    Matched MeSH terms: Ultrasonography/standards
  3. Tawfik EA, Cartwright MS, Grimm A, Boon AJ, Kerasnoudis A, Preston DC, et al.
    Muscle Nerve, 2019 10;60(4):361-366.
    PMID: 31335971 DOI: 10.1002/mus.26642
    Neuromuscular ultrasound has become an essential tool in the diagnostic evaluation of various neuromuscular disorders, and, as such, there is growing interest in neuromuscular ultrasound training. Effective training is critical in mastering this modality. Our aim was to develop consensus-based guidelines for neuromuscular ultrasound training courses. A total of 18 experts participated. Expert opinion was sought through the Delphi method using 4 consecutive electronic surveys. A high degree of consensus was achieved with regard to the general structure of neuromuscular ultrasound training; the categorization of training into basic, intermediate, and advanced levels; the learning objectives; and the curriculum for each level. In this study, a group of neuromuscular ultrasound experts established consensus-based guidelines for neuromuscular ultrasound training. These guidelines can be used in the development of the specialty and the standardization of neuromuscular ultrasound training courses and workshops.
    Matched MeSH terms: Ultrasonography/standards*
  4. Dengler R, de Carvalho M, Shahrizaila N, Nodera H, Vucic S, Grimm A, et al.
    Clin Neurophysiol, 2020 07;131(7):1662-1663.
    PMID: 32354605 DOI: 10.1016/j.clinph.2020.03.014
    Modern neuromuscular electrodiagnosis (EDX) and neuromuscular ultrasound (NMUS) require a universal language for effective communication in clinical practice and research and, in particular, for teaching young colleagues. Therefore, the AANEM and the IFCN have decided to publish a joint glossary as they feel the need for an updated terminology to support educational activities in neuromuscular EDX and NMUS in all parts of the world. In addition NMUS has been rapidly progressing over the last years and is now widely used in the diagnosis of disorders of nerve and muscle in conjunction with EDX. This glossary has been developed by experts in the field of neuromuscular EDX and NMUS on behalf of the AANEM and the IFCN and has been agreed upon by electronic communication between January and November 2019. It is based on the glossaries of the AANEM from 2015 and of the IFCN from 1999. The EDX and NMUS terms and the explanatory illustrations have been updated and supplemented where necessary. The result is a comprehensive glossary of terms covering all fields of neuromuscular EDX and NMUS. It serves as a standard reference for clinical practice, education and research worldwide.
    Matched MeSH terms: Ultrasonography/standards*
  5. Hussain A, Via G, Melniker L, Goffi A, Tavazzi G, Neri L, et al.
    Crit Care, 2020 12 24;24(1):702.
    PMID: 33357240 DOI: 10.1186/s13054-020-03369-5
    COVID-19 has caused great devastation in the past year. Multi-organ point-of-care ultrasound (PoCUS) including lung ultrasound (LUS) and focused cardiac ultrasound (FoCUS) as a clinical adjunct has played a significant role in triaging, diagnosis and medical management of COVID-19 patients. The expert panel from 27 countries and 6 continents with considerable experience of direct application of PoCUS on COVID-19 patients presents evidence-based consensus using GRADE methodology for the quality of evidence and an expedited, modified-Delphi process for the strength of expert consensus. The use of ultrasound is suggested in many clinical situations related to respiratory, cardiovascular and thromboembolic aspects of COVID-19, comparing well with other imaging modalities. The limitations due to insufficient data are highlighted as opportunities for future research.
    Matched MeSH terms: Ultrasonography/standards
  6. Nusee Z, Ibrahim N, Rus RM, Ismail H
    Taiwan J Obstet Gynecol, 2014 Mar;53(1):12-6.
    PMID: 24767639 DOI: 10.1016/j.tjog.2013.01.028
    To determine the accuracy of bladder volume (BV) measurement and to identify factors that influenced the ultrasound bladder scanner (UBS) measurement of BV in postpartum women compared with transurethral catheterization.
    Matched MeSH terms: Ultrasonography/standards
  7. Ho CH, Ismail AK, Liu SH, Tzeng YS, Li LY, Pai FC, et al.
    Clin Toxicol (Phila), 2021 Sep;59(9):794-800.
    PMID: 33605805 DOI: 10.1080/15563650.2021.1881535
    BACKGROUND: The incidence of acute compartment syndrome (ACS) following snakebite envenomation may be seriously overestimated in Taiwan. Snakebite-induced ACS is difficult to determine solely by clinical examination. Snakebite patients previously underwent surgical intervention based on speculation and general clinical examinations suggesting ACS presentations instead of direct intracompartmental pressure (IP) measurement prior to fasciotomy. Point-of-care ultrasound (POCUS) is a relatively widely available noninvasive tool. This study aimed to evaluate snakebite-envenomated patients for the presence of subcutaneous edema and diastolic retrograde arterial flow (DRAF).

    MATERIALS AND METHODS: Snakebite patients were prospectively recruited between 2017 and 2019. All patients were examined with POCUS to locate edema and directly visualize and measure the arterial flow in the compressed artery. The presence of DRAF in the compressed artery is suggestive of ACS development because when compartment space restriction occurs, increased retrograde arterial flow is observed in the artery.

    RESULTS: Twenty-seven snakebite patients were analyzed. Seventeen patients (63%) were bitten by Crotalinae snakes, seven (26%) by Colubridae, one (4%) by Elapidae, and two (7%) had unidentified snakebites. All Crotalinae bit patients received antivenom, had subcutaneous edema and lacked DRAF in a POCUS examination series.

    DISCUSSION: POCUS facilitates clinical decisions for snakebite envenomation. We also highlighted that the anatomic site of the snakebite is an important factor affecting the prognosis of the wounds. There were limitations of this study, including a small number of patients and no comparison with the generally accepted invasive evaluation for ACS.

    CONCLUSIONS: We are unable to state that POCUS is a valid surrogate measurement of ACS from this study but see this as a starting point to develop further research in this area. Further study will be needed to better define the utility of POCUS in patients envenomated by snakes throughout the world.

    Matched MeSH terms: Ultrasonography/standards*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links