Displaying all 17 publications

Abstract:
Sort:
  1. Chen M, Fargen KM, Mocco J, Siddiqui AH, Miyachi S, Mahadevan J, et al.
    J Neurointerv Surg, 2023 Jul;15(7):623-628.
    PMID: 37147004 DOI: 10.1136/jnis-2023-020309
    Matched MeSH terms: Radiology, Interventional*
  2. Moradi F, Jalili M, Saraee KRE, Abdi MR, Rashid HAA
    Biomed Phys Eng Express, 2024 Feb 14;10(2).
    PMID: 38320327 DOI: 10.1088/2057-1976/ad26d5
    The inherent biological hazards associated with ionizing radiation necessitate the implementation of effective shielding measures, particularly in medical applications. Interventional radiology, in particular, poses a unique challenge as it often exposes medical personnel to prolonged periods of high x-ray doses. Historically, lead and lead-based compounds have been the primary materials employed for shielding against photons. However, the drawbacks of lead, including its substantial weight causing personnel's inflexibility and its toxicity, have raised concerns regarding its long-term impact on both human health and the environment. Barium tantalate has emerged as a promising alternative, due to its unique attenuation properties against low-energy x-rays, specifically targeting the weak absorption area of lead. In the present study, we employ the Geant4 Monte Carlo simulation tool to investigate various formulations of barium tantalate doped with rare earth elements. The aim is to identify the optimal composition for shielding x-rays in the context of interventional radiology. To achieve this, we employ a reference x-ray spectrum typical of interventional radiology procedures, with energies extending up to 90 keV, within a carefully designed simulation setup. Our primary performance indicator is the reduction in air kerma transmission. Furthermore, we assess the absorbed doses to critical organs at risk within a standard human body phantom protected by the shield. Our results demonstrate that specific concentrations of the examined rare earth impurities can enhance the shielding performance of barium tantalate. To mitigate x-ray exposure in interventional radiology, our analysis reveals that the most effective shielding performance is achieved when using barium tantalate compositions containing 15% Erbium or 10% Samarium by weight. These findings suggest the possibility of developing lead-free shielding solutions or apron for interventional radiology personnel, offering a remarkable reduction in weight (exceeding 30%) while maintaining shielding performance at levels comparable to traditional lead-based materials.
    Matched MeSH terms: Radiology, Interventional*
  3. Yaacob Y, Nguyen DV, Mohamed Z, Ralib AR, Zakaria R, Muda S
    Indian J Radiol Imaging, 2013 Apr;23(2):121-5.
    PMID: 24082475 DOI: 10.4103/0971-3026.116543
    To report our early experience in image-guided chemoport insertions by interventional radiologists.
    Matched MeSH terms: Radiology, Interventional
  4. Fum WKS, Md Shah MN, Raja Aman RRA, Abd Kadir KA, Wen DW, Leong S, et al.
    Phys Eng Sci Med, 2023 Dec;46(4):1535-1552.
    PMID: 37695509 DOI: 10.1007/s13246-023-01317-5
    In fluoroscopy-guided interventions (FGIs), obtaining large quantities of labelled data for deep learning (DL) can be difficult. Synthetic labelled data can serve as an alternative, generated via pseudo 2D projections of CT volumetric data. However, contrasted vessels have low visibility in simple 2D projections of contrasted CT data. To overcome this, we propose an alternative method to generate fluoroscopy-like radiographs from contrasted head CT Angiography (CTA) volumetric data. The technique involves segmentation of brain tissue, bone, and contrasted vessels from CTA volumetric data, followed by an algorithm to adjust HU values, and finally, a standard ray-based projection is applied to generate the 2D image. The resulting synthetic images were compared to clinical fluoroscopy images for perceptual similarity and subject contrast measurements. Good perceptual similarity was demonstrated on vessel-enhanced synthetic images as compared to the clinical fluoroscopic images. Statistical tests of equivalence show that enhanced synthetic and clinical images have statistically equivalent mean subject contrast within 25% bounds. Furthermore, validation experiments confirmed that the proposed method for generating synthetic images improved the performance of DL models in certain regression tasks, such as localizing anatomical landmarks in clinical fluoroscopy images. Through enhanced pseudo 2D projection of CTA volume data, synthetic images with similar features to real clinical fluoroscopic images can be generated. The use of synthetic images as an alternative source for DL datasets represents a potential solution to the application of DL in FGIs procedures.
    Matched MeSH terms: Radiology, Interventional
  5. Qurash MT, Yaacob NY, Azuan N, Khaleel YS, Zakaria R
    J Med Ultrasound, 2018 06 18;26(4):210-214.
    PMID: 30662153 DOI: 10.4103/JMU.JMU_40_18
    Interventional radiology procedures are becoming more challenging over time; thus, there is a need for excellent and reliable training methods. Training on live patients is neither safe nor an ethical solution. Alternatives are many and varied, but the most popular is ultrasound guided simulators. This report shows how a simple, homemade, low-cost phantom material, and construction modules can provide several advantages over ordinary gelatin phantoms. A new layering technique and target synthesis are described for the biopsy phantom, including tips on decreasing the needle pass artifact as well as controlling the mixture echogenicity.
    Matched MeSH terms: Radiology, Interventional
  6. Safari MJ, Wong JH, Ng KH, Jong WL, Cutajar DL, Rosenfeld AB
    Med Phys, 2015 May;42(5):2550-8.
    PMID: 25979047 DOI: 10.1118/1.4918576
    The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures.
    Matched MeSH terms: Radiology, Interventional/instrumentation*; Radiology, Interventional/methods*
  7. Safari MJ, Wong JHD, Jong WL, Thorpe N, Cutajar D, Rosenfeld A, et al.
    Phys Med, 2017 Mar;35:66-72.
    PMID: 28256398 DOI: 10.1016/j.ejmp.2017.02.002
    PURPOSE: The purpose of this study was to investigate the effects of routine exposure parameters on patient's dose during neuro-interventional radiology procedures.

    METHODS: We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors.

    RESULTS: DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region.

    CONCLUSION: Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures.

    Matched MeSH terms: Radiology, Interventional/instrumentation; Radiology, Interventional/methods*
  8. Teoh AYB, Dhir V, Kida M, Yasuda I, Jin ZD, Seo DW, et al.
    Gut, 2018 Jul;67(7):1209-1228.
    PMID: 29463614 DOI: 10.1136/gutjnl-2017-314341
    OBJECTIVES: Interventional endoscopic ultrasonography (EUS) procedures are gaining popularity and the most commonly performed procedures include EUS-guided drainage of pancreatic pseudocyst, EUS-guided biliary drainage, EUS-guided pancreatic duct drainage and EUS-guided celiac plexus ablation. The aim of this paper is to formulate a set of practice guidelines addressing various aspects of the above procedures.

    METHODS: Formulation of the guidelines was based on the best scientific evidence available. The RAND/UCLA appropriateness methodology (RAM) was used. Panellists recruited comprised experts in surgery, interventional EUS, interventional radiology and oncology from 11 countries. Between June 2014 and October 2016, the panellists met in meetings to discuss and vote on the clinical scenarios for each of the interventional EUS procedures in question.

    RESULTS: A total of 15 statements on EUS-guided drainage of pancreatic pseudocyst, 15 statements on EUS-guided biliary drainage, 12 statements on EUS-guided pancreatic duct drainage and 14 statements on EUS-guided celiac plexus ablation were formulated. The statements addressed the indications for the procedures, technical aspects, pre- and post-procedural management, management of complications, and competency and training in the procedures. All statements except one were found to be appropriate. Randomised studies to address clinical questions in a number of aspects of the procedures are urgently required.

    CONCLUSIONS: The current guidelines on interventional EUS procedures are the first published by an endoscopic society. These guidelines provide an in-depth review of the current evidence and standardise the management of the procedures.

    Matched MeSH terms: Radiology, Interventional
  9. Yaacob Y, Zakaria R, Mohammad Z, Ralib AR, Muda AS
    Malays J Med Sci, 2011 Oct;18(4):98-102.
    PMID: 22589680
    Central venous catheter placement is indicated in patients requiring long-term therapy. With repeated venous catheterisations, conventional venous access sites can be exhausted. This case illustrates the expanding role of radiology in managing difficult venous access. We present a case of translumbar, transhepatic, and transcollateral placement of central catheter in a woman with a difficult venous access problem who required lifelong parenteral nutrition secondary to short bowel syndrome. This case highlights the technical aspects of interventional radiology in vascular access management.
    Matched MeSH terms: Radiology, Interventional
  10. Md Ralib AR, Han NT, Hin HS, Muda AS
    Malays J Med Sci, 2010 Jul;17(3):55-60.
    PMID: 22135550 MyJurnal
    Massive haemoptysis is the most dreaded of all respiratory emergencies. Bronchial artery embolisation is known to be a safe and effective procedure in massive haemoptysis. Bronchial artery of anomalous origin presents a diagnostic challenge to interventional radiologists searching for the source of haemorrhage. Here, we report a case of massive haemoptysis secondary to a lung carcinoma with the bronchial artery originating directly from the right subclavian artery. This artery was not evident during the initial flush thoracic aortogram. The anomalous-origin bronchial artery was then embolised using 15% diluted glue with good results. An anomalous-origin bronchial artery should be suspected if the source of haemorrhage is not visualised in the normally expected bronchial artery location.
    Matched MeSH terms: Radiology, Interventional
  11. Bohari A, Hashim S, Ghoshal SK, Mohd Mustafa SN
    Radiat Prot Dosimetry, 2019 Dec 31;186(4):462-468.
    PMID: 31329977 DOI: 10.1093/rpd/ncz051
    Long exposure to radiation from fluoroscopy-guided interventions (FGIs) can be detrimental to both patients and radiologists. The effective doses received by the interventional radiology staff after performing 230 FGIs in a year were assessed by using double dosimetry and five various algorithms. The Shapiro-Wilk test revealed normally-distributed data (p < 0.01), while the significant correlation coefficients between the effective doses ranged between 0.88 and 1.00. As for the Bland-Altman analysis, both Niklason and Boetticher algorithms strongly supported the absence of statistical significance between the estimated effective doses. This portrays that the occupational doses received by the interventional radiology staff during FGIs fall within the acceptable limit regardless of the varied algorithms applied. In short, the Niklason and Boetticher algorithms appeared to be the more interchangeable ones for effective evaluation of doses. This is in view of their strong mutual correlations and excellent agreement.
    Matched MeSH terms: Radiology, Interventional/methods*
  12. Wong JHD, Anem LEA, Tan S, Tan SK, Ng KH
    Phys Med, 2019 Dec;68:47-51.
    PMID: 31739145 DOI: 10.1016/j.ejmp.2019.11.007
    OBJECTIVE: This study measured the radiation exposure of the eye lens of medical personnel performing fluoroscopy and interventional procedures at the Sarawak General Hospital in Kuching, Sarawak, Malaysia. This study was the first in Malaysia to utilise in vivo radiation measurement relatively near the eye lens.

    METHODS: 41 medical personnel performing 79 procedures were monitored for their eye lens exposure using the NanoDot™ optically-stimulated luminescence dosimeters (OSLD) taped to the outer canthus of their eyes. The air-kerma area product (KAP), fluoroscopy time (FT) and number of procedure runs were also recorded.

    RESULTS: KAP, FT and number of runs were strongly correlated. However, only weak to moderate correlations were observed between these parameters with the measured eye lens doses. The average median equivalent eye lens dose was 0.052 mSv (ranging from 0.0155 to 0.672 mSv). The eye lens doses of primary operators were found to be significantly higher than their assistants due to the closer proximity to the patient and X-ray tube. The left eye lens of the operators received the highest amount of radiation due to their habitual positioning towards the radiation source.

    CONCLUSION: KAP and FT were not useful in predicting the equivalent eye lens dose exposure in interventional radiological procedures. Direct in vivo measurements were needed to provide a better estimate of the eye lens doses received by medical personnel during these procedures. This study highlights the importance of using direct measurement, such as OSLDs, instead of just indirect factors to monitor dose in the eye lens in radiological procedures.

    Matched MeSH terms: Radiology, Interventional*
  13. Acharya UR, Hagiwara Y, Sudarshan VK, Chan WY, Ng KH
    J Zhejiang Univ Sci B, 2018 1 9;19(1):6-24.
    PMID: 29308604 DOI: 10.1631/jzus.B1700260
    Radiology (imaging) and imaging-guided interventions, which provide multi-parametric morphologic and functional information, are playing an increasingly significant role in precision medicine. Radiologists are trained to understand the imaging phenotypes, transcribe those observations (phenotypes) to correlate with underlying diseases and to characterize the images. However, in order to understand and characterize the molecular phenotype (to obtain genomic information) of solid heterogeneous tumours, the advanced sequencing of those tissues using biopsy is required. Thus, radiologists image the tissues from various views and angles in order to have the complete image phenotypes, thereby acquiring a huge amount of data. Deriving meaningful details from all these radiological data becomes challenging and raises the big data issues. Therefore, interest in the application of radiomics has been growing in recent years as it has the potential to provide significant interpretive and predictive information for decision support. Radiomics is a combination of conventional computer-aided diagnosis, deep learning methods, and human skills, and thus can be used for quantitative characterization of tumour phenotypes. This paper discusses the overview of radiomics workflow, the results of various radiomics-based studies conducted using various radiological images such as computed tomography (CT), magnetic resonance imaging (MRI), and positron-emission tomography (PET), the challenges we are facing, and the potential contribution of radiomics towards precision medicine.
    Matched MeSH terms: Radiology, Interventional/methods*
  14. Yaacob Y, Muda S, Zakaria R
    Ann Thorac Med, 2012 Apr;7(2):107-9.
    PMID: 22558017 DOI: 10.4103/1817-1737.94534
    This was a case of a 35-year-old man with mediastinal mass requiring computed tomography (CT)-guided biopsy for tissue diagnosis. A posterior approach with an 18-gauge biopsy needle was used to obtain tissue sample. Post biopsy, patient condition deteriorated and multiphase CT study detected active bleeding in arterial phase at the biopsy site with massive hemothorax. Subsequent angiography showed arterial bleeder arising from the apical branch of the right pulmonary artery. Selective endovascular embolization with NBCA (n-Butyl cyanoacrylate) was successful. Patient survived the complication. The case highlighted a rare complication in a common radiology procedure and the value of the interventional radiology unit in avoiding a fatal outcome.
    Matched MeSH terms: Radiology, Interventional
  15. Ng KL, Nawawi O, Lim BK, Htun TH, Dublin N, Razack AH
    Asian J Surg, 2017 Apr;40(2):171-174.
    PMID: 24210538 DOI: 10.1016/j.asjsur.2013.09.012
    Ureteric strictures are common and can be due to benign or malignant causes. Various surgical treatments can be used from minimally invasive endoscopic retrograde JJ stent insertion, balloon dilatation, ureterolithotomy, to open surgical exploration and repair. Memokath 051 stent is a metallic stent designed for long-term ureteral stenting in the management of ureteral strictures. The insertion of this device is usually a straightforward procedure performed endoscopically in a retrograde fashion via cystoscopy. However, this procedure can be difficult in complicated scenarios when the bladder has been removed with neoureteral reimplantations or high-grade strictures. Here, we report a case of Memokath stent insertion complicated by placement difficulties in a lady with ileal conduit due to previous ovarian cancer complicated by vesicovaginal fistula, who presented with malignant stricture of the ureteroileal anastomosis. We describe a simple yet effective antegrade technique to precisely reposition the malpositioned Memokath stent, along with illustrations.
    Matched MeSH terms: Radiology, Interventional/methods*
  16. Letchumanan VP, Lim KF, Mohamad AB
    Med J Malaysia, 2013 Oct;68(5):405-9.
    PMID: 24632870 MyJurnal
    INTRODUCTION: Spontaneous rupture is a dramatic presentation of HCC and it carries high mortality rate. To study the outcomes of ruptured HCC patients managed at a tertiary referral centre in Malaysia.
    METHODS: A retrospective review of all ruptured HCC patients managed as inpatient at the Department of Hepatobiliary Surgery, Hospital Selayang between January 2001 and December 2010. Data was retrieved from the hospital electronic medical records, Powerchart (Cerner Corporation Inc., USA) and supplemented with registry from Interventional Radiology record of chemoembolization and registry from hepatobiliary operative surgery records.
    RESULTS: There were 22 patients admitted with confirmed diagnosis of ruptured HCC over 10 years period. The common clinical findings on presentation were abdominal pain and presence of shock (36.4%). The mortality rate was 81.8% with only four patients noted to be alive during the follow up. One year overall survival for ER and DR are 40.0% and 72.7% respectively and the median survival in patients treated with DR was 433.3 days whereas it was 212.5 days in ER group.
    CONCLUSIONS: This study supports the clinical practice of TAE should be the first line treatment followed by staged surgery in suitable candidates with ruptured HCC.
    Matched MeSH terms: Radiology, Interventional
  17. Md Noh MSF, Abdul Rashid AM, Abdul Rahim E
    J Bronchology Interv Pulmonol, 2018 07;25(3):e30-e32.
    PMID: 29944591 DOI: 10.1097/LBR.0000000000000456
    Matched MeSH terms: Radiology, Interventional
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links