METHODS: Stool samples were collected prospectively from symptomatic adults who had elective colonoscopy from September 2014 to January 2016 and were analyzed with the ScheBo M2-PK Quick test and laboratory detection of fecal hemoglobin.
RESULTS: The results were correlated to the colonoscopy findings and/or histopathology report. Eighty-five subjects (age of 56.8 ± 15.3 years [mean ± standard deviation]) were recruited with a total of 17 colorectal cancer (20.0%) and 10 colorectal adenoma patients (11.8%). The sensitivity of M2-PK test in colorectal cancer detection was higher than gFOBT (100% vs. 64.7%). M2-PK test had a lower specificity when compared to gFOBT (72.5% vs. 88.2%) in colorectal cancer detection. The positive and negative predictive values were 47.2% and 100% for M2-PK test and 57.9% and 90.9% for gFOBT.
CONCLUSION: Fecal M2-PK Quick test has a high sensitivity for detection of colorectal cancer when compared to gFOBT, making it the potential choice for colorectal tumor screening biomarker in the future.
METHODS: Patients referred to the Endoscopic Unit for colonoscopy were recruited for the study. Stool samples were collected prior to bowel preparation, and tested for occult blood with both gFOBT and FIT. Dietary restriction was not imposed. To assess the validity of either tests or in combination to detect a neoplasm or cancer in the colon, their false positive rates, their sensitivity (true positive rate) and the specificity (true negative rate) were analyzed and compared.
RESULTS: One hundred and three patients were analysed. The sensitivity for picking up any neoplasia was 53% for FIT, 40% for gFOBT and 23.3% for the combination. The sensitivities for picking up only carcinoma were 77.8% , 66.7% and 55.5%, respectively. The specificity for excluding any neoplasia was 91.7% for FIT, 74% for gFOBT and 94.5% for a combination, whereas for excluding only carcinomas they were 84%, 73.4% and 93.6%. Of the 69 with normal colonoscopic findings, FOBT was positive in 4.3%, 23.2 %and 2.9% for FIT, gFOBT, or combination of tests respectively.
CONCLUSION: FIT is the recommended method if we are to dispense with dietary restriction in our patients because of its relatively low-false positivity and better sensitivity and specificity rates.