Displaying publications 1 - 20 of 23 in total

Abstract:
Sort:
  1. Patil PG, Nimbalkar-Patil SP
    J Prosthodont, 2018 Mar;27(3):314-316.
    PMID: 27333596 DOI: 10.1111/jopr.12491
    Accurate planning for the framework design of removable partial dentures requires careful analysis of the diagnostic cast with a dental surveyor to determine the optimal path of placement. Some techniques described in the literature are helpful in reorienting the same cast on the surveyor, including the tripod marking method; however, there is a possibility of introducing human errors during marking and repositioning of the tripod points on to the different casts at the same location. Other techniques, which do not require markings on the cast to reorient different casts of the same patient, need specific devices or trays. This article suggests the direct use of a putty-elastomeric orientation index that can be preserved and used multiple times while reorienting different casts of the same patients at various laboratory steps. A putty elastomeric impression material is mixed and adapted on to the diagnostic cast, covering key teeth areas of the cast and incorporating the analyzing rod of the surveyor. Thus there is no need to use a special device or the tray to reorient different casts.
    Matched MeSH terms: Denture, Partial, Removable*
  2. Sivakumar I, Arunachalam S, Buzayan MM
    J Dent Educ, 2023 Jun;87 Suppl 1:892-894.
    PMID: 36469857 DOI: 10.1002/jdd.13153
    Matched MeSH terms: Denture, Partial, Removable*
  3. Ng JYM, Lim TW, Tarib N, Ho TK
    Health Informatics J, 2021 7 31;27(3):14604582211035821.
    PMID: 34325550 DOI: 10.1177/14604582211035821
    This study aimed to evaluate the effect of a novel progressive web application (PWA) on the patient's oral and denture knowledge and hygiene. Fifty-two removable partial denture wearers were randomised to receive education using the PWA, or verbal instructions accompanied by demonstration of hygienic procedures. Changes in the participants' knowledge score, plaque index, gingival index and denture plaque was evaluated during a follow-up period of 3 months. The participants' acceptance of PWA was explored through usage logs and a feedback form. Both groups showed significant improvement in knowledge scores, oral and denture hygiene indices (p < 0.001) after education. The PWA group demonstrated significantly lower gingival index score than control (p = 0.008) at the third month review. In conclusion, there is potential of using mobile application in educating elderly patients and the PWA is a viable option for providing post-denture delivery instructions.
    Matched MeSH terms: Denture, Partial, Removable*
  4. Choong EKM, Shu X, Leung KCM, Lo ECM
    J Dent, 2022 Dec;127:104351.
    PMID: 36280004 DOI: 10.1016/j.jdent.2022.104351
    OBJECTIVES: To summarise evidence on the change in oral health-related quality of life (OHRQoL) before and after rehabilitation with removable partial dentures (RPDs) amongst partially edentulous adults.

    DATA: Studies assessing OHRQoL amongst patients aged ≥18 years, before and after rehabilitation with RPDs of any type and design, were included. The quality of included studies was evaluated using the Cochrane risk of bias tools. Meta-analysis was conducted using a random-effect model.

    SOURCES: MEDLINE, EMBASE and CENTRAL, up to March 29, 2022.

    STUDY SELECTION AND RESULTS: Thirteen studies were eligible and eight were included in the meta-analysis. The studies had moderate to serious risk of bias. There was a very low level of certainty that OHRQoL, as measured using OHIP-14, improved 3 months after RPDs were fitted (222 participants, MD: -12.0, 95% CI: -16.1, -7.9, p<0.001) and after 6 months (101 participants, MD: -10.5, 95% CI: -16.4, -4.6, p<0.001). At 12 months post-treatment, RPD rehabilitation did not result in statistically significant improvement in OHIP-14 scores (62 participants, MD: -12.7, 95% CI: -26.1, 0.6, p = 0.06). However, the assessment using OHIP-49 at 12 months showed significant improvement (87 participants, MD: -34.8, 95% CI: -41.9, -27.7, p<0.001), with low certainty of evidence.

    CONCLUSIONS: Based on the limited evidence available, this review found that RPD rehabilitation appear to improve OHRQoL in the short term up to 6 months, with a very low level of certainty. The long-term effect of RPD treatment on OHRQoL after 12 months is inconclusive. There is currently insufficient evidence on the effect of RPD treatment on OHRQoL. This review highlights the need for more and better quality studies.

    CLINICAL SIGNIFICANCE: Data on RPD outcomes are summarised, aiding clinicians in providing evidence-based patient-centred care that matches patients' needs and expectations. Recommendations for future research were also highlighted.

    REGISTRATION: PROSPERO CRD42022328606.

    Matched MeSH terms: Denture, Partial, Removable*
  5. Kamsiah GH, Ramli Y, Idris AY
    Quintessence Int, 1993 May;24(5):311-2.
    PMID: 8362043
    A technique in which the custom-made anterior ceramometal pontics are securely attached to the metal framework of a Kennedy Class IV removable partial denture is described. This technique results in a more esthetic prosthesis with less palatal coverage.
    Matched MeSH terms: Denture, Partial, Removable*
  6. Abd-Shukor SN, Yahaya N, Tamil AM, Botelho MG, Ho TK
    Eur J Dent Educ, 2021 Nov;25(4):744-752.
    PMID: 33368978 DOI: 10.1111/eje.12653
    INTRODUCTION: The application of video-based learning in dentistry has been widely investigated; however, the nature of on-screen video enhancements of the video has been minimally explored in the literature. This study investigated the effectiveness of an in-class and on-demand enhanced video to support learning on removable partial dentures in terms of knowledge acquisition, perception and clinical skill performance.

    METHODS: Fifty-four dental students enrolled in 2018 were recruited as participants and assigned to two groups. Both groups were given the same lecture and asked to watch the same video in either the enhanced or non-enhanced version. The enhanced video was modified with the contemporaneous subtitle of the presenters' dialogue, text bullet points and summary text pages. The knowledge acquisition from the two types of video was subjected to pre- and post-tests one month after the students watched the video. A questionnaire was used to evaluate the students' perceptions of the learning experience and a performance test on practical skills was performed after six weeks. All the students responded to the test (100%).

    RESULTS: The enhanced video demonstration improved the students' short-term knowledge acquisition after they watched the video, with an average score of 1.59 points higher in the enhanced group than in the non-enhanced group (p 

    Matched MeSH terms: Denture, Partial, Removable*
  7. Patil PG, Lim HF
    J Prosthet Dent, 2023 Jul;130(1):14-18.
    PMID: 34774303 DOI: 10.1016/j.prosdent.2021.08.005
    Fabricating a new crown to retrofit with an existing removable partial denture (RPD) is a complex procedure for both clinician and dental laboratory technician. The presented technique facilitates the fabrication and retrofitting of a metal-ceramic crown onto the principal abutment of the existing RPD by using 2-step intraoral scanning (with and without the RPD in place) and 2 different 3-dimensionally printed casts. The technique enables the dental laboratory technician to precisely reproduce the retentive areas, guiding planes, and rest seats on the retrofitted crown.
    Matched MeSH terms: Denture, Partial, Removable*
  8. Yahya, A.N., Radzi, Z., Yusof, Z.Y.M.
    Malaysian Dental Journal, 2007;28(1):34-37.
    MyJurnal
    This clinical case report describes an aspect of restorative management of worn teeth. It illustrates the use of diagnostic overlay removable partial denture or DORPD, which has the same function as occlusal splint but with advantages of providing immediate aesthetic improvement and function.
    Matched MeSH terms: Denture, Partial, Removable
  9. Chen J, Ahmad R, Suenaga H, Li W, Sasaki K, Swain M, et al.
    PLoS One, 2015;10(7):e0132552.
    PMID: 26161878 DOI: 10.1371/journal.pone.0132552
    With ever-growing aging population and demand for denture treatments, pressure-induced mucosa lesion and residual ridge resorption remain main sources of clinical complications. Conventional denture design and fabrication are challenged for its labor and experience intensity, urgently necessitating an automatic procedure. This study aims to develop a fully automatic procedure enabling shape optimization and additive manufacturing of removable partial dentures (RPD), to maximize the uniformity of contact pressure distribution on the mucosa, thereby reducing associated clinical complications. A 3D heterogeneous finite element (FE) model was constructed from CT scan, and the critical tissue of mucosa was modeled as a hyperelastic material from in vivo clinical data. A contact shape optimization algorithm was developed based on the bi-directional evolutionary structural optimization (BESO) technique. Both initial and optimized dentures were prototyped by 3D printing technology and evaluated with in vitro tests. Through the optimization, the peak contact pressure was reduced by 70%, and the uniformity was improved by 63%. In vitro tests verified the effectiveness of this procedure, and the hydrostatic pressure induced in the mucosa is well below clinical pressure-pain thresholds (PPT), potentially lessening risk of residual ridge resorption. This proposed computational optimization and additive fabrication procedure provides a novel method for fast denture design and adjustment at low cost, with quantitative guidelines and computer aided design and manufacturing (CAD/CAM) for a specific patient. The integration of digitalized modeling, computational optimization, and free-form fabrication enables more efficient clinical adaptation. The customized optimal denture design is expected to minimize pain/discomfort and potentially reduce long-term residual ridge resorption.
    Matched MeSH terms: Denture, Partial, Removable*
  10. Ann LK
    Dent J Malaysia Singapore, 1968 Feb;8(1):29-32.
    PMID: 4882517
    Matched MeSH terms: Denture, Partial, Removable
  11. Nik Madihah Nik Azis, Khamiza Zainol Abidin
    MyJurnal
    The practice of quack dentistry worldwide is a challenge to the profession of dentistry as it undermines the trust of the general public and places the patients at unnecessary risks through their illegal practices. Although the ratio of patients to dentists is rapidly decreasing in Malaysia due to the increased output of qualified dentists from both local and foreign institutions, quack dentistry is still practiced in many areas. This report intends to highlight a popular treatment prescribed by these quack dentists which is removable partial dentures that is fixed to the adjacent teeth by cold cure acrylic. We also aim to discuss the design of the denture and the means employed to remove this ’fixed partial denture’. It is hoped that this case report will highlight the prevalence of the practice of quack dentistry especially in geographical area of this case report and allow the authorities to devise means to stop this illegal practice.
    Matched MeSH terms: Denture, Partial, Removable
  12. Awang, R.A.R., Arief, E.M., Hassan, A.
    MyJurnal
    Since the establishment of implant in dentistry, the use of removable partial denture in replacing missing teeth apparently becomes less popular. The situation is made worse by the renowned limitations of removable partial denture. One of the obvious limitations of removable partial denture, especially in replacing missing anterior teeth is the unsightly view of metal used for retentive clasp. This case report describes the use of spring loaded plunger attachments as an alternative way to achieve retention and at the same time improving the aesthetic of the prosthesis.
    Matched MeSH terms: Denture, Partial, Removable
  13. Turagam N, Mudrakola DP, Yelamanchi RS, Deepthi M, Natarajan M
    J Int Soc Prev Community Dent, 2019 02 14;9(1):94-98.
    PMID: 30923701 DOI: 10.4103/jispcd.JISPCD_220_18
    Denture esthetics as defined by Glossary of prosthodontics terms the effect produced by a dental prosthesis that affects the beauty and attractiveness of the person. [1] Removable partial dentures (RPDs) are the widely accepted and treatment of choice for most cases as it is both effective and affordable. Partially edentulous treatment planning includes both esthetics and masticatory function. A prosthesis that is highly esthetic will improve patient's motivation and acceptance. It is a very wrong notion to expect that patients will tolerate unesthetic partial dentures because good masticatory capability has been achieved. Esthetics plays a vital role in the success of partial dentures, and the length and mobility of the patient's lips play a significant role in achieving it. [2] Patients with short lips or highly mobile lips pose problems as esthetics are compromised because most clasp arms, denture borders, and other components will show when the patient smiles or speaks. [3] RPDs can easily look artificial; hence, special emphasis should aim toward restoring function, phonetics, esthetics with a long-term benefits which requires meticulous attention during fabrication. This case reports is an esthetic clasp designed for a cast partial denture for a young girl for esthetic and function.
    Matched MeSH terms: Denture, Partial, Removable
  14. Yusof Z, Isa Z
    J Oral Rehabil, 1994 Jan;21(1):77-86.
    PMID: 8133391
    The aims of the study were to determine the periodontal status of the teeth in contact with removable partial dentures (RPDs) and to compare them with other teeth in the opposing arch not related to any prosthesis. The periodontal status was also assessed in relation to the age of the dentures. Four hundred and twenty-seven patients treated with RPDs from 1981 to 1986 were recalled for examination. Prior to prosthetic treatment they were given periodontal treatment and fillings when required. Initially all were given oral hygiene instructions and motivation. They were reviewed regularly only on a short-term basis. Eighteen patients were suitable for the present study comprising of eight males and 10 females whose mean age was 41 years. The RPDs were in use from 1.5 to 8 years (mean 4.6 years). The following parameters were assessed: Plaque index (P1I), Gingival index (GI), loss of attachment (LA) and tooth mobility. The wearing of RPDs resulted in higher P1I, GI and LA compared to the controls and these differences were statistically significant. There was an increased frequency of higher P1I, GI and LA with the increase in denture age. Minor changes in tooth mobility were observed. It was concluded that the wearing of RPDs was detrimental to periodontal health in patients whose oral hygiene was less than adequate.
    Matched MeSH terms: Denture, Partial, Removable/adverse effects*
  15. Ahmed N, Abbasi MS, Haider S, Ahmed N, Habib SR, Altamash S, et al.
    Biomed Res Int, 2021;2021:3194433.
    PMID: 34532499 DOI: 10.1155/2021/3194433
    Objective: Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional techniques.

    Materials and Methods: The present systematic review was carried out according to PRISMA guidelines. The search was carried out on PubMed/MEDLINE, Cochrane collaboration, Science direct, and Scopus scientific engines using selected MeSH keywords. The articles fulfilling the predefined selection criteria based on the fit and accuracy of removable partial denture (RPD) frameworks constructed from digital workflow (CAD/CAM; rapid prototyping) and conventional techniques were included.

    Results: Nine full-text articles comprising 6 in vitro and 3 in vivo studies were included in this review. The digital RPDs were fabricated in all articles by CAD/CAM selective laser sintering and selective laser melting techniques. The articles that have used CAD/CAM and rapid prototyping technique demonstrated better fit and accuracy as compared to the RPDs fabricated through conventional techniques. The least gaps between the framework and cast (41.677 ± 15.546 μm) were found in RPDs constructed through digital CAD/CAM systems.

    Conclusion: A better accuracy was achieved using CAD/CAM and rapid prototyping techniques. The RPD frameworks fabricated by CAD/CAM and rapid prototyping techniques had clinically acceptable fit, superior precision, and better accuracy than conventionally fabricated RPD frameworks.

    Matched MeSH terms: Denture, Partial, Removable/trends*
  16. Rahman AM, Nizami MMUI, Jamayet NB, Husein A
    J Coll Physicians Surg Pak, 2017 May;27(5):319-320.
    PMID: 28599699 DOI: 2623
    Matched MeSH terms: Denture, Partial, Removable*
  17. Ling BC
    Quintessence Int, 1995 Dec;26(12):871-7.
    PMID: 8596818
    This article presents an alternative to the conventional swing-lock de sign of removable partial denture construction. It incorporates the principles of sectional dentures as well as the swing-lock concept and overcomes some of the limitations of conventional swing-lock dentures. I-bar struts and stainless steel keepers form part of the first section of the denture. The second part of the denture consists of the denture base with the artificial teeth and magnetic retention units. This system has been used successfully in a number of patients whose situations were suitable for the conventional swing-lock design.
    Matched MeSH terms: Denture, Partial, Removable*
  18. Ab-Murat N, Sheiham A, Watt R, Tsakos G
    BMC Oral Health, 2015 Mar 13;15:36.
    PMID: 25887142 DOI: 10.1186/s12903-015-0015-9
    The traditional measure for assessing dental treatment needs and workforce requirements based solely on normative need (NN) has major shortcomings. The sociodental approach (SDA) to assess needs overcomes some of the shortcomings as it combines normative and subjective needs assessments and also incorporates behavioural propensity (Sheiham and Tsakos 2007). The objective of this study was to estimate and compare prosthodontic treatment needs and workforce requirements, using the normative and the sociodental approaches for different skill mix models.
    Matched MeSH terms: Denture, Partial, Removable/statistics & numerical data
  19. Isa Z, Yusof Z
    J Oral Rehabil, 1990 Nov;17(6):541-50.
    PMID: 2283549
    The aims of this study were to determine the dental and periodontal status and the associated treatment needs, other than that for prosthetic care, in patients who requested removable partial dentures. Forty-six patients who had never worn removable partial dentures before were examined for plaque index, tooth status, gingival index, loss of periodontal attachment and tooth mobility. Prior to prosthetic treatment, 15% of the teeth needed conservative treatment and 1% needed extractions. From the periodontal point of view, 65% of the teeth needed some form of related therapy, and 2% of the teeth were at risk of extraction due to advanced mobility.
    Matched MeSH terms: Denture, Partial, Removable/statistics & numerical data*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links