Displaying all 3 publications

Abstract:
Sort:
  1. Anandan S, Othman M, Cheong I, Chin GL
    Singapore Med J, 1995 Oct;36(5):559-61.
    PMID: 8882549
    In recent years there have been many reports of connective tissue diseases especially scleroderma following exposure to silica and silicone. We report a 51-year-old Chinese who developed a scleroderma-like disease and pulmonary silicosis eight years after exposure to silica. To our knowledge, this is the first case to be reported in Malaysia.
  2. Azlan CA, Ng KH, Anandan S, Nizam MS
    Australas Phys Eng Sci Med, 2006 Sep;29(3):278-80.
    PMID: 17058591
    Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.
  3. Rajamma DB, Anandan S, Yusof NSM, Pollet BG, Ashokkumar M
    Ultrason Sonochem, 2021 Apr;72:105413.
    PMID: 33338865 DOI: 10.1016/j.ultsonch.2020.105413
    Acoustic cavitation and sonochemical reactions play a significant role in various applications of ultrasound. A number of dosimetry methods are in practice to quantify the amount of radicals generated by acoustic cavitation. In this study, hydroxyl radical (OH) yields measured by Weissler, Fricke and terephthalic acid dosimetry methods have been compared to evaluate the validities of these methods using a 490 kHz high frequency sonochemical reactor. The OH yields obtained after 5 min sonication at 490 kHz from Weissler and Fricke dosimetries were 200 µM and 289 µM, respectively. Whereas, the OH yield was found to be very low (8 µM) when terephthalic acid dosimetry was used under similar experimental conditions. While the results agree with those reported by Iida et al. (Microchem. J., 80 (2005) 159), further mechanistic details and interfering reactions have been discussed in this study. For example, the amount of OH determined by the Weissler and Fricke methods may have some uncertainty due to the formation of HO2 in the presence of oxygen. In order to account for the major discrepancy observed with the terephthalic acid dosimetry method, high performance liquid chromatography (HPLC) analysis was performed, where two additional products other than 2-hydroxy terephthalic acid were observed. Electrospray ionization mass spectrometry (ESI-MS) analysis showed the formation of 2,5-dihydroxyterephthalic acid as one of the by-products along with other unidentified by-products. Despite the formation of additional products consuming OH, the reason for a very low OH yield obtained by this dosimetry could not be justified, questioning the applicability of this method, which has been used to quantify OH yields generated not only by acoustic cavitation, but also by other processes such as γ-radiolysis. The authors are hoping that this Opinion Paper may initiate further discussion among researchers working in sonochemistry area that could help resolve the uncertainties around using these dosimetry methods.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links