Dosimeter pendarcahaya terma (TLD) telah mula digunakan untuk tujuan perlindungan sinaran. Peratus kepudaran yang rendah untuk satu jangka panjang merupakan salah satu kelebihannya. Harshaw sebagai salah satu pembekal telah mendokumenkan kepudaran TLD mereka iaitu kurang dari 2% untuk masa penyimpanan tidak melebihi tiga bulan. Kajian yang dijalankan di MINT ini menguji kepudaran TLD-100H Harshaw untuk tempoh 30 hari. Disamping mengesahkan apa yang telah didokumenkan, kajian ini mengesyorkan TLD dibaca setelah empat hari masa penyimpanan.
For a range of doses familiarly incurred in computed tomography (CT), study is made of the performance of Germanium (Ge)-doped fibre dosimeters formed into cylindrical and flat shapes. Indigenously fabricated 2.3 mol% and 6 mol% Ge-dopant concentration preforms have been used to produce flat- and cylindrical-fibres (FF and CF) of various size and diameters; an additional 4 mol% Ge-doped commercial fibre with a core diameter of 50 μm has also been used. The key characteristics examined include the linearity index f(d), dose sensitivity and minimum detectable dose (MDD), the performance of the fibres being compared against that of lithium-fluoride based TLD-100 thermoluminescence (TL) dosimeters. For doses in the range 2-40 milligray (mGy), delivered at constant potential of 120 kilovoltage (kV), both the fabricated and commercial fibres demonstrate supralinear behaviours at doses 4 mGy. In terms of dose sensitivity, all of the fibres show superior TL sensitivity when compared against TLD-100, the 2.3 mol% and 6 mol% Ge-doped FF demonstrating the greatest TL sensitivity at 84 and 87 times that of TLD-100. The TL yields for the novel Ge-doped silica glass render them appealing for use within the present medical imaging dose range, offering linearity at high sensitivity down to less than 2 mGy.
Personal dosimeters are used by medical radiation workers (MRWs) to monitor their radiation dose from external sources and comply with radiation safety guidelines. Nevertheless, there is evidence of inconsistent use of the devices among MRWs. Behavioral factors influencing the use of personal dosimeters have never been explored. Using established behavioral models, we aimed to develop a psychometric tool to measure the behavioral factors influencing dosimeter use and establish its feasibility, reliability, and validity. A 37-item tool was developed based on a qualitative study and review of the literature. The content relevancy was assessed by six field experts before it was piloted and re-tested on MRWs. The construct validity of the tool was analyzed using exploratory factor analysis to confirm its psychometric properties. Face validation was performed by academicians, field experts, and MRWs to enhance the tool's readability. The 37 items in the tool belonged to five constructs in the early phase. However, the validation study revealed a reliable 27 item tool with seven constructs, namely: "Attitude," "Social factors," "Ability to perform if facilitated," "Ability to overcome shortcomings," "Self-efficacy," "Complexity," and "Perceived usefulness." The item-construct validity index of accepted items was >0.83, and Cronbach's alpha for each construct ranged between 0.70 to 0.96, while factor loading for each item was between 0.723 to 0.963. All results were considered "good" and "excellent." The new tool appears to be valid, reliable, and feasible to measure behavioral factors influencing personal dosimeter use among MRWs, which is helpful to facilitate the planning of interventions to improve behaviors in occupational radiation monitoring.
For x- and gamma- irradiations delivering entrance doses from 2- up to 1000 Gy to commercial 1.0 mm thick borosilicate glass microscope slides, study has been made of their thermoluminescence yield. With an effective atomic number of 10.6 (approximating bone equivalence), photon energy dependency is apparent in the low x-ray energy range, with interplay between the photoelectric effect and attenuation. As an example, over the examined dose range, at 120 kVp the photon sensitivity has been found to be some 5× that of 60Co gamma irradiations, also with repeatability to within ~1%. The glow-curves, taking the form of a single prominent broad peak, have been deconvolved yielding at best fit a total of five peaks, the associated activation energies and frequency factors also being obtained. The results indicate borosilicate glass slides to offer promising performance as a low-cost passive radiation dosimeter, with utility for both radiotherapy and industrial applications.
The ideal imaging system that is providing a good quality image of minimal radiation dose. There are many parameters that influenced image quality and radiation dose on clinical radiography. This study has identified some of the problems whereby there are practitioners do not select the proper size of image receptor (IR) and collimation during the examination. The re-usable of the IR and imaging plate also need to be concerned whether multiple exposures may affect the image
quality or not. The purpose of this study is to investigate the effect of different exposure settings; kVp, mAs, collimation field sizes and different IR’ sizes for image quality and radiation dose. Methods: The wall-mounted x-ray machine act as a sources of radiation which exposed the acrylic cylinder that placed over the IR. The examination is repeated with different kVp, mAs, collimation field sizes and IR’s sizes. The source to image distance (SID) is fixed to 100 cm distance and put Nano dot dosimeter similar level with the top of acrylic to measure the dose. The result analysed by using software ImageJ to measure the Contrast to Noise Ratio (CNR). Results: The percentage of CNR1 and CNR2 reduced as the kVp is increased from (CNR1=77.25, CNR2=64.45), (CNR1=73.47, CNR2=61.22) and (CNR1=62.80, CNR2=57.32) for 50 kVp, 75 kVp and 100 kVp respectively and fluctuate when mAs increased. The CNR and entrance skin dose (ESD) shows higher when x-ray beam collimate according to IR’s size. Conclusions: Overall, the manipulative effect of exposure settings on image quality and ESD shows some positive results. The result also shows inconsistent readings in the CNR and ESD. The percentage of CNR decreased when kVp increases and slightly fluctuate when mAs increased. The ESD reading depicts higher when the kVp and mAs increase as well as when x-ray beam collimated according to IR’s sizes.
This study evaluates the ImageJ software as dosimetric tools for analyzing the film dosimeter in high energy photons and electrons. The percentage depth dose of photons of 6 and 10 MV and electrons of 6 and 9 MeV were measured using the Gafchromic EBT2 film dosimeter. The films were scanned and analyzed using the Verisoft software and ImageJ. The beam profiles at nominal photon and electron beam parameters were also evaluated using the two methods. The PDD measured in ImageJ at high energy photons were in good agreement within 1% percentage of discrepancy at all depths in comparison to the Verisoft software. The PDD measured in ImageJ at high energy electrons also showed good agreement to Verisoft software within 8% percentage of discrepancy at all depths. The measured flatness of beam profiles at Dmax, R50, R80 and R90 in ImageJ were also in good agreement to Verisoft software with flatness value between 4 and 8%. The results indicated the suitability of ImageJ software as dosimetric tool for analyzing EBT2 film dosimeter at high energy photon and electrons.
Using irradiated doped-silica preforms from which fibres for thermoluminescence dosimetry applications can be fabricated we have carried out a range of luminescence studies, the TL yield of the fibre systems offering many advantages over conventional passive dosimetry types. In this paper we investigate such media, showing emission spectra for irradiated preforms and the TL response of glass beads following irradiation to an 241Am-Be neutron source located in a tank of water, the glass fibres and beads offering the advantage of being able to be placed directly into liquid. The outcomes from these and other lines of research are intended to inform development of doped silica radiation dosimeters of versatile utility, extending from environmental evaluations through to clinical and industrial applications.
With interest in the potential of optical fibres as the basis of next-generation thermoluminescence dosimeters (TLDs), the development of suitable forms of material and their fabrication has become a fast-growing endeavour. Present study focuses on three types of Ge-doped optical fibres with different structural arrangements and/or shapes, namely conventional cylindrical fibre, capillary fibre, and flat fibre, all fabricated using the same optical fibre preform. For doses from 0.5 to 8 Gy, obtained at electron and photon energies, standard thermoluminescence (TL) characteristics of the optical fibres have been the subject of detailed investigation. The results show that in collapsing the capillary fibre into a flat shape, the TL yield is increased by a factor of 5.5, the yield being also some 3.2 times greater than that of the conventional cylindrical fibre fabricated from the same perform. This suggests a means of production of suitably sensitive TLD for in-vivo dosimeter applications. Addressing the associated defects generating luminescence from each of the optical fibres, the study encompasses analysis of the TL glow curves, with computerized glow curve deconvolution (CGCD) and 2(nd) order kinetics.
Recreational noise exposure has become a major threat to the hearing system, and this
includes exposure to loud noise during group exercises such as Zumba Fitness, where loud music plays an
important role. This study aimed to assess the noise exposure and hearing threshold profile among Zumba
Fitness regulars in Kuantan, Malaysia. MATERIALS AND METHODS: Noise exposure and hearing profile
threshold were measured during Zumba Fitness sessions at a fitness studio in Kuantan, Malaysia from 24th
June 2014 to 12th August 2014. Noise exposure was measured using a noise dosimeter for one hour of Zumba
Fitness session with a total of nine sessions run by three different instructors while sound level pressure was
taken using a sound level meter during ambient, peak session and during cooling down. Thirty participants
answered questionnaires and underwent pure tone diagnostic audiometry test at a local clinic for hearing
threshold documentation. RESULTS: Some areas of the hall posed higher risks of causing noise-induced
hearing loss especially near the amplifiers. There were periods when the hearing level exceeded 115 dBA.
Early abnormal pattern could be observed in the hearing profiles of some of the participants to suggest
preliminary hearing problems. CONCLUSION: Zumba Fitness regulars have a risk of developing noise-induced
hearing loss and preventive steps should be properly addressed as NIHL is permanent and irreversible.
This phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size-specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter-100 (TLD-100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen-pelvic CT. With use of TCM, the ED was 6.50±0.29 mSv for thoracic and 6.01±0.20 mSv for the abdomen-pelvic CT protocols. However without use of TCM, the ED was 20.07±0.24 mSv and 17.30±0.41 mSv for the thoracic and abdomen-pelvic CT protocols, respectively. The corresponding SSDE was 10.18±0.48 mGy and 11.96±0.27 mGy for the thoracic and abdomen-pelvic CT protocols with TCM, and 31.56±0.43 mGy and 33.23±0.05 mGy for thoracic and abdomen-pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58±0.12 mGy in the TCM protocols and 51.52±14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen-pelvic CT, the absorbed dose was highest at the skin with 9.30±1.28 mGy and 29.99±2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen-pelvic CT. PACS numbers: 87.57.Q-, 87.57.qp, 87.53.Bn.
The effect of sodium as a co-dopant on the thermoluminescence (TL) properties of copper-doped zinc lithium borate (ZLB: Cu) subjected to Co-60 gamma radiation is reported in this study. TL intensity is enhanced with the introduction of sodium in ZLB: Cu. The obtained glow curve is simple with a single peak. The annealing procedure and the best heating rate for the proposed thermoluminescent dosimeter (TLD) are established, and the phosphor is reusable. The TL response within the dose range of 0.5-1000Gy is investigated. The results show that the thermal fading behaviour is improved significantly.
The performance of optically stimulated luminescence dosimeters (OSLDs, Al2O3:C) was evaluated in terms of the operational quantity of HP(10) in Co-60 external beam teletherapy unit. The reproducibility, signal depletion, and dose linearity of each dosimeter was investigated. For ten repeated readouts, each dosimeter exposed to 50mSv was found to be reproducible below 1.9 ± 3% from the mean value, indicating good reader stability. Meanwhile, an average signal reduction of 0.5% per readout was found. The dose response revealed a good linearity within the dose range of 5-50mSv having nearly perfect regression line with R2 equals 0.9992. The accuracy of the measured doses were evaluated in terms of operational quantity HP(10), wherein the trumpet curve method was used respecting the 1990 International Commission on Radiological Protection (ICRP) standard. The accuracy of the overall measurements from all dosimeters was discerned to be within the trumpet curve and devoid of outlier. It is established that the achieved OSL Al2O3:C dosimeters are greatly reliable for equivalent dose assessment.
Ge-doped silica fibre (GDSF) thermoluminescence dosimeters (TLD) are non-hygroscopic spatially high-resolution radiation sensors with demonstrated potential for radiotherapy dosimetry applications. The INTRABEAM® system with spherical applicators, one of a number of recent electronic brachytherapy sources designed for intraoperative radiotherapy (IORT), presents a representative challenging dosimetry situation, with a low keV photon beam and a desired rapid dose-rate fall-off close-up to the applicator surface. In this study, using the INTRABEAM® system, investigations were made into the potential application of GDSF TLDs for in vivo IORT dosimetry. The GDSFs were calibrated over the respective dose- and depth-range 1 to 20 Gy and 3 to 45 mm from the x-ray probe. The effect of different sizes of spherical applicator on TL response of the fibres was also investigated. The results show the GDSF TLDs to be applicable for IORT dose assessment, with the important incorporated correction for beam quality effects using different spherical applicator sizes. The total uncertainty in use of this type of GDSF for dosimetry has been found to range between 9.5% to 12.4%. Subsequent in vivo measurement of skin dose for three breast patients undergoing IORT were performed, the measured doses being below the tolerance level for acute radiation toxicity.
An intercomparison exercise (IC) on whole body dosemeters to determine the quantity personal dose equivalent Hp (10) in photon radiation fields was jointly organised and conducted by the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for individual monitoring services (IMS) in Asia and the Pacific region. This was arranged to help the IMS in the region to achieve a more accurate dosimetry service and to improve their performance. Twenty-four IMS participated in this IC. Four sets of dosemeters were irradiated using X-ray and gamma radiation qualities at 0° and 20° angle of incidence, respectively. All the IMS provided results that were within the acceptable limits defined by the IAEA. However, only a minority of participants reported confidence intervals that included the reference dose, for each exposure scenario. For few systems, the overall performance could be significantly improved by reviewing calibration procedures.
This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reader accuracy, reproducibility, batch homogeneity, energy dependence and signal stability, were explored. The suitability of the nanoDot™ dosemeters was evaluated by measuring the depth dose curve, in vivo dose measurement and image perturbation. The nanoDot™ dosemeters were observed to produce a linear dose with ±2.8% coefficient variation. Significant batch inhomogeneity (8.3%) was observed. A slight energy dependence (±6.1%) was observed between 60 and 140 kVp. The InLight® microStar reader demonstrated good accuracy and a reproducibility of ±2%. The depth dose curve measured using nanoDot™ dosemeters showed slightly lower responses than Monte Carlo simulation results. The total uncertainty for a single dose measurement using this system was 11%, but it could be reduced to 9.2% when energy dependence correction was applied.
Computed tomography (CT) fluoroscopy is able to give real time images to a physician undertaking minimally invasive procedures such as biopsies, percutaneous drainage, and radio frequency ablation (RFA). Both operators executing the procedure and patients too, are thus at risk of radiation exposure during a CT fluoroscopy.This study focuses on the radiation exposure present during a series of radio frequency ablation (RFA) procedures, and used Gafchromic film (Type XR-QA; International Specialty Products, USA) and thermoluminescent dosimeters (TLD-100H; Bicron, USA) to measure the radiation received by patients undergoing treatment, and also operators subject to scatter radiation.The voltage was held constant at 120 kVp and the current 70mA, with 5mm thickness. The duration of irradiation was between 150-638 seconds.Ultimately, from a sample of 30 liver that have undergone RFA, the study revealed that the operator received the highest dose at the hands, which was followed by the eyes and thyroid, while secondary staff dosage was moderately uniform across all parts of the body that were measured.
Workers who are exposed to high noise level were at risk of noise-induced hearing loss (NIHL). This crosssectional study was conducted to investigate the noise exposure level and hearing symptoms among workers exposed to noise in a teaching hospital. Utilising convenience sampling method, 20 laundry workers and 17 mechanical cutters were recruited into this study. Noise exposure levels were measured using noise dosimeter for 8 hours and information on hearing symptoms were gathered using a modified questionnaire adopted from the American Speech Language Hearing Association (ASHA). A significantly higher mean noise level (85±2 dB(A)) was reported among mechanical cutters as compared to laundry workers (80±3 dB(A)), p=0.001 although the former had shorter duration of noise exposure (20±3 hours per week vs. 28±12 hours per week). Fourteen (70%) laundry workers and six (35%) mechanical cutters had reported having hearing problem in noisy background. Higher proportion of laundry workers (n=8, 57%) had reported hearing symptoms compared to mechanical cutters (n=6, 43%) and longer work years was found to be significantly associated with hearing symptoms (p=0.049). There is a need of appropriate education and training on noise exposure, NIHL and hearing protection devices usage in the workplaces
Introduction: Clinical studies have shown that people suffering from tinnitus are at a high risk of developing serious psychological disturbances or serious psychological distress (Erlandsson &
Widen, 2004 in Hiller and Goebel, 1998). Thus the purpose of this study was to determine the
relationship between life-time noise exposure and tinnitus experience among young adults in IIUM Kuantan. Methods: A cross sectional study was used to determine whether there is any association between tinnitus experiences and life-time noise exposure among 11 young adults in IIUM Kuantan from age of 18 to 35 years old who are exposed to the noise. Hearing assessment was done using otoscopy, tympanometry and pure tone audiometry. Participants were asked to fill in a questionnaire on tinnitus experience, and were fitted with a noise dosimeter that measured their noise exposure during waking hours. Values collected from dosimeter were then converted into cumulative life-time noise exposure which refers to the equivalent noise exposure per year (Jokitulppo, Tolvenen & Bjork, 2005). Results: Average cumulative life-time noise exposure of the participants is 72.54 dBA ± 6.9459. Fifty five percent (55%) reported of sometimes having tinnitus. No correlation was found between cumulative life-time noise exposure and tinnitus experience. Conclusion: The cumulative life-time noise exposure among young adults in IIUM Kuantan was found to be lower than the level considered as hazardous. Despite reports of tinnitus experience, there was no evidence that the tinnitus was due to noise exposure.
Using tailor-made sub-mm dimension doped-silica fibres, thermoluminescent dosimetric studies have been performed for α-emitting sources of 223RaCl2 (the basis of the Bayer Healthcare product Xofigo®). The use of 223RaCl2 in the palliative treatment of bone metastases resulting from late-stage castration-resistant prostate cancer focuses on its favourable uptake in metabolically active bone metastases. Such treatment benefits from the high linear energy transfer (LET) and associated short path length (<100µm) of the α-particles emitted by 223Ra and its decay progeny. In seeking to provide for in vitro dosimetry of the α-particles originating from the 223Ra decay series, investigation has been made of the TL yield of various forms of Ge-doped SiO2 fibres, including photonic crystal fibre (PCF) collapsed, PCF uncollapsed, flat and single-mode fibres. Irradiations of the fibres were performed at the UK National Physical Laboratory (NPL). Notable features are the considerable sensitivity of the dosimeters and an effective atomic number Zeff approaching that of bone, the glass fibres offering the added advantage of being able to be placed directly into liquid. The outcome of present research is expected to inform development of doped fibre dosimeters of versatile utility, including for applications as detailed herein.
There are several factors that may contribute to the increase in radiation dose of CT including the use of unoptimized protocols and improper scanning technique. In this study, we aim to determine significant impact on radiation dose as a result of mis-centering during CT head examination. The scanning was performed by using Toshiba Aquilion 64 slices multi-detector CT (MDCT) scanner and dose were measured by using calibrated ionization chamber. Two scanning protocols of routine CT head; 120 kVp/ 180 mAs and 100 kVp/ 142 mAs were used represent standard and low dose, respectively. As reference measurement, the dose was first measured on standard cylindrical polymethyl methacrylate (PMMA) phantom that positioned at 104 cm from the floor (reference isocenter). The positions then were varied to simulate mis-centering by 5 cm from isocenter, superiorly and inferiorly at 109 cm, 114 cm, 119 cm, 124 cm and 99 cm, 94 cm, 89 cm, 84 cm, respectively. Scanning parameter and dose information from the console were recorded for the radiation effective dose (E) measurement. The highest mean CTDIvol value for MCS and MCI were 105.06 mGy (at +10 cm) and 105.51 mGy (at - 10 cm), respectively which differed significantly (p