Displaying all 5 publications

Abstract:
Sort:
  1. Ho YL, Khamis AY, Abdul Kareem BA
    J Cardiothorac Surg, 2024 Jul 10;19(1):427.
    PMID: 38982433 DOI: 10.1186/s13019-024-02817-5
    INTRODUCTION: Pulmonary regurgitation (PR) remains a common sequela in patients following surgically corrected TOF, and may lead to progressive right ventricle dilatation and dysfunction. The conventional approach of redo-sternotomy for pulmonary valve replacement (PVR) is associated with increased operative time as well as risks of bleeding and injury to the heart and great vessels. Thus, left anterior mini-thoracotomy has become an alternative approach in eliminating the risks of redo-sternotomy in these patients. This series aimed to determine the outcomes of minimally invasive pulmonary valve replacement after surgical TOF correction.

    METHODS: A retrospective analysis was conducted on 24 patients with severe PR post-surgical TOF correction who underwent left anterior mini-thoracotomy PVR in Penang General Hospital from January 2021 to January 2023.

    RESULTS: The median age was 23.5 years (I.Q.range 17.6-36.3), with a male:female ratio of 1:4. Majority of patients had mild to moderate symptoms prior to surgery and 19 patients (79.1%) were on regular diuretics medication. All patients had severe free-flow PR with evidence of right ventricular dilatation and dysfunction. Magnetic Resonance Imaging and computed tomography of pulmonary artery were performed prior to surgery. Minimally invasive PVR was performed on all patients via left upper anterior mini-thoracotomy and femoral-femoral bypass without cardioplegic arrest. The operative time and cardiopulmonary bypass time were 208 (I.Q.range 172-324) and 98.6 minutes(I.Q.range 87.4-152.4) respectively. The time to wean off inotropes postoperatively was 6.2 hours (I.Q.range1.4-14.8), and no postoperative arrhythmia and chest re-exploration were reported. Most patients stayed in Intensive Care Unit (ICU) for 10.8 hours (I.Q.range 8.4-36.5), and the total hospital stay was 4.2 days (I.Q.range 3.4-7.6). 2 patients (11.1%) required blood transfusion postoperative. There was no paravalvular leak and no mortality during the follow-up period of up to 28 months.

    CONCLUSION: Minimally invasive PVR after surgical correction of TOF is a safe alternative to the conventional redo-sternotomy approach in patients with favorable anatomy. This approach is able to reduce the risks associated with redo-sternotomy, particularly bleeding and injury to mediastinal structures, with the additional benefit of expedited recovery and hospital discharge. Our series has shown a safe and efficient approach in these patients with favorable outcomes.

    Matched MeSH terms: Pulmonary Valve/surgery
  2. Ram SP, Lim MK, Mazeni A
    Med J Malaysia, 1994 Mar;49(1):93-5.
    PMID: 8057999
    A 7-year old female child was admitted for recurrent bronchopulmonary since one week of life. She was diagnosed to have ventricular septal defect and was treated conservatively. At seven years of life, repeat echocardiogram revealed a large perimembranous ventricular septal defect, absent pulmonary valve with overriding of aorta, narrow pulmonary artery annulus, and dilated main pulmonary artery and its branches. She was treated conservatively, discharged and follow-up at the National Heart Institute Kuala Lumpur, for corrective surgery.
    Matched MeSH terms: Pulmonary Valve/surgery
  3. Alwi M, Budi RR, Mood MC, Leong MC, Samion H
    Cardiol Young, 2013 Apr;23(2):197-202.
    PMID: 22640635 DOI: 10.1017/S1047951112000595
    Objective: To determine the feasibility and safety of the Conquest Pro wire as an alternative to radiofrequency wire for perforation of atretic pulmonary valve and subsequent balloon dilatation and patent ductus arteriosus stenting in patients with pulmonary atresia with intact ventricular septum.
    Background: Radiofrequency valvotomy and balloon dilatation has become the standard of care for pulmonary atresia with intact ventricular septum in many institutions today.
    Methods: We report eight consecutive patients in whom we used the Conquest Pro coronary guidewire, a stiff wire normally reserved for revascularisation of coronary lesions with chronic total occlusion, for perforation of atretic pulmonary valve and subsequent balloon dilatation, and stenting of the patent ductus arteriosus.
    Results: Perforation of atretic pulmonary valve was successful in seven out of eight cases. Radiofrequency valvotomy was employed after failure of perforation by the Conquest Pro wire in one case where the right ventricular outflow tract was broad based and tapered towards the pulmonary valve, and was heavily trabeculated. Failure of the Conquest Pro wire to perforate the pulmonary valve plate was mainly attributed by the failure to engage the wire at the correct position.
    Conclusion: The Conquest Pro wire for perforation and subsequent interventions in the more straightforward cases of pulmonary atresia with intact ventricular septum is effective and safe, simplifying the entire procedure. However, the radiofrequency generator and wires remain essential tools in the paediatric interventional catheter laboratory.
    Matched MeSH terms: Pulmonary Valve/surgery*
  4. Qureshi AU, Abbaker AE, Sivalingam S, Latiff HA
    PMID: 24668992 DOI: 10.1177/2150135113509819
    Valved bovine jugular vein (Contegra) conduit is considered a suitable choice for pediatric population with congenital heart defect requiring right ventricle to main pulmonary artery connection. Intermediate follow-up studies have shown the propensity of developing distal conduit stenosis and valve thrombosis. We present a rare case of aneurysmal dilatation of the conduit leading to valve failure requiring conduit explantation.
    Matched MeSH terms: Pulmonary Valve/surgery
  5. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Pulmonary Valve/surgery*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links