Anterior corpectomy and reconstruction using a plate with locking screws are standard procedures for the treatment of cervical spondylotic myelopathy. Although adding more screws to the construct will normally result in improved fixation stability, several issues need to be considered. Past reports have suggested that increasing the number of screws can result in the increase in spinal rigidity, decreased spine mobility, loss of bone and, possibly, screw loosening. In order to overcome this, options to have constrained, semi-constrained or hybrid screw and plate systems were later introduced. The purpose of this study is to compare the stability achieved by four and two screws using different plate systems after one-level corpectomy with placement of cage. A three-dimensional finite-element model of an intact C1-C7 segment was developed from computer tomography data sets, including the cortical bone, soft tissue and simulated corpectomy fusion at C4-C5. A spinal cage and an anterior cervical plate with different numbers of screws and plate systems were constructed to a fit one-level corpectomy of C5. Moment load of 1.0 N m was applied to the superior surface of C1, with C7 was fixed in all degrees of freedom. The kinematic stability of a two-screw plate was found to be statistically equivalent to a four-screw plate for one-level corpectomy. Thus, it can be a better option of fusion and infers comparable stability after one-level anterior cervical corpectomy, instead of a four-screw plate.
The conventional upper arm tourniquet used for hand and wrist operations may cause significant discomfort to patient when the procedure is performed under local anaesthesia. Forearm tourniquet causes less muscle ischeamia and pain. The discomfort experienced while using a forearm and upper arm tourniquet was assessed in 96 healthy subjects. Tourniquet placed on both sides was inflated sequentially to 250mmhg for five minutes on different hand. The discomfort level was assessed using a small visual analogue scale and complications were recorded. In the upper arm tourniquet, 24.9% had mild, 60.5% had moderate and 14.6% had severe pain whereas with forearm tourniquet, 99% had mild pain and only 1% had moderate pain. Seventy-nine percent of the subjects tested with forearm tourniquet had no discomfort at all. The average discomfort level for upper arm and forearm tourniquet was 4.72 and 0.39 respectively, which is statistically significant. Complications that were observed only in upper arm tourniquet included prolonged tingling, burning sensation and discomfort and stiffness of the upper limb. We concluded that forearm tourniquet was safe and well tolerated and should be used more often when indicated.
We report a case of an 11-year-old boy with osteosarcoma of the proximal humerus treated with wide excision and reconstruction with a cement spacer-prosthesis. After seven years of follow-up, the patient is now almost a young adult. We present his current physical and functional status, which seems to defray the initial doubts regarding long-term problems when we chose this method of reconstruction.
Glove perforation during surgery has always been a matter of concern as it increases the infection rate and the risk of transmission of blood borne diseases. To determine the common causes, the site and the awareness of glove perforations in orthopaedic surgery, a prospective study was conducted to assess the rate of glove perforation during 130 consecutive orthopaedic operations. All gloves worn by the surgical team were assessed after the surgery using the water-loading test. A total of 1452 gloves were tested, and the rate of perforation was 3.58%. Most of these perforations (61.5%) were unnoticed. The main surgeons had the most perforations (76.9%), followed by first assistants (13.5%) and second assistants (9.6%). Most perforations occurred at the non-dominant hand. The commonest site of perforation was the index finger followed by the thumb. Shearing force with instruments accounted for 45% of the noticed perforations. Majority of these occurred during nailing procedures (33%) and internal fixation without the use of wires (19%). Our rate of glove perforation is similar to other series. Most of them went unnoticed and were mainly due to shearing injuries rather than perforation by sharps. Therefore, there is an increased risk of contamination and break in asepsis during surgery.
Sleeve fracture of the inferior pole of the patella is a rare and distinctive fracture in children with few published reports. These fractures are frequently misdiagnosed and neglected. We highlight a case of a neglected and misdiagnosed sleeve fracture of the patella in an eleven-year-old boy. This was initially diagnosed as an avulsion fracture of the tibial tubercle. A good outcome was achieved after open reduction and internal fixation.
A case of traumatic posterior cruciate ligament (PCL) avulsion fracture presenting with unusual radiographic findings is described. CT scan of the right knee showed features suggestive of combined ACL and PCL avulsion fractures. Arthroscopic findings showed that the injury was in fact a PCL avulsion fracture that was displaced anteriorly so as to mimic an ACL avulsion fracture on CT scan.