Displaying publications 1 - 20 of 64 in total

Abstract:
Sort:
  1. Jahani Fariman H, Ahmad SA, Hamiruce Marhaban M, Alijan Ghasab M, Chappell PH
    Australas Phys Eng Sci Med, 2016 Mar;39(1):85-102.
    PMID: 26581764 DOI: 10.1007/s13246-015-0399-5
    This research proposes an exploratory study of a simple, accurate, and computationally efficient movement classification technique for prosthetic hand application. Surface myoelectric signals were acquired from the four muscles, namely, flexor carpi ulnaris, extensor carpi radialis, biceps brachii, and triceps brachii, of four normal-limb subjects. The signals were segmented, and the features were extracted with a new combined time-domain feature extraction method. Fuzzy C-means clustering method and scatter plot were used to evaluate the performance of the proposed multi-feature versus Hudgins' multi-feature. The movements were classified with a hybrid Adaptive Resonance Theory-based neural network. Comparative results indicate that the proposed hybrid classifier not only has good classification accuracy (89.09%) but also a significantly improved computation time.
    Matched MeSH terms: Forearm
  2. Burns-Cox CJ
    Med J Malaya, 1965 Jun;19(4):318-9.
    PMID: 4220860
    Matched MeSH terms: Forearm/pathology*
  3. Yeak RDK, Yap YY, Nasir NM
    J Coll Physicians Surg Pak, 2021 Nov;31(11):1357-1358.
    PMID: 34689498 DOI: 10.29271/jcpsp.2021.11.1357
    Wrist drop post-venepuncture is uncommon. There has been reported cases of direct injury to the radial nerve during venepuncture but to our knowledge, there has never been a case of posterior interosseous nerve (PIN) injury. A 34-year female, right hand dominant homemaker, with a newly diagnosed diabetes mellitus, was admitted for diabetic ketoacidosis. There was difficult access with multiple attempts in her blood taking over the antebrachial fossa and forearm. Thereafter, she was unable to fully extend her wrist, fingers and thumb with an intact sensation. The electrophysiological study was suggestive of demyelinating right radial neuropathy at the elbow. Despite the transient blood taking session, patient developed neuropraxia, which only resolved after four months. We wish to report this case of unusual presentation of a PIN palsy post- routine venepuncture, which can result in high morbidity to a patient. Key Words: Posterior interosseous nerve syndrome, venepuncture, neuropraxia, wrist drop.
    Matched MeSH terms: Forearm*
  4. Dharap AS, Shaharuddin MY
    Med J Malaysia, 1994 Sep;49(3):239-41.
    PMID: 7845272
    Patterns of superficial veins of the cubital fossa were studied in 170 male and 96 female Malays. Six venous patterns were observed. The less commonly known but clinically important patterns observed included absence of communication between basilic and cephalic veins (in 7.3% females and 8.8% males); an arched median cubital vein (in 2.0% females and 6.5% males); absence of the cephalic vein (in 1.0% females and 2.9% males) and two median cubital veins (in 1 male only). Awareness of these uncommon cubital venous patterns and their approximate incidence would be very useful for those performing venepuncture or venesection in Malays, especially under emergency conditions.
    Matched MeSH terms: Forearm/blood supply*
  5. Abd Rashid AH, Ibrahim S
    Strategies Trauma Limb Reconstr, 2010 Dec;5(3):145-7.
    PMID: 21286359 DOI: 10.1007/s11751-010-0089-5
    Nonunion following diaphyseal forearm fracture is an uncommon complication in children. Compression plate fixation with bone grafting has been the standard method to treat this complication. We report a case of hypertrophic nonunion of the ulna in a child who was treated surgically using an elastic stable intramedullary nail (ESIN) without bone grafting. The nonunion healed 4 months after surgery.
    Matched MeSH terms: Forearm; Forearm Injuries
  6. Mohamad Ismail MR, Lam CK, Sundaraj K, Rahiman MHF
    J Musculoskelet Neuronal Interact, 2021 12 01;21(4):481-494.
    PMID: 34854387
    OBJECTIVE: This paper presents the analyses of the fatigue effect on the cross-talk in mechanomyography (MMG) signals of extensor and flexor forearm muscles during pre- and post-fatigue maximum voluntary isometric contraction (MVIC).

    METHODS: Twenty male participants performed repetitive submaximal (60% MVIC) grip muscle contractions to induce muscle fatigue and the results were analyzed during the pre- and post-fatigue MVIC. MMG signals were recorded on the extensor digitorum (ED), extensor carpi radialis longus (ECRL), flexor digitorum superficialis (FDS) and flexor carpi radialis (FCR) muscles. The cross-correlation coefficient was used to quantify the cross-talk values in forearm muscle pairs (MP1, MP2, MP3, MP4, MP5 and MP6). In addition, the MMG RMS and MMG MPF were calculated to determine force production and muscle fatigue level, respectively.

    RESULTS: The fatigue effect significantly increased the cross-talk values in forearm muscle pairs except for MP2 and MP6. While the MMG RMS and MMG MPF significantly decreased (p<0.05) based on the examination of the mean differences from pre- and post-fatigue MVIC.

    CONCLUSION: The presented results can be used as a reference for further investigation of cross-talk on the fatigue assessment of extensor and flexor muscles' mechanic.

    Matched MeSH terms: Forearm*
  7. Ahmad Ruzain, S., Zar Chi, T., Syed Baharom, S.A.F.
    Medicine & Health, 2018;13(2):164-169.
    MyJurnal
    Presented herein is a case of one different morphological anomaly of pronator quadratus (PQ) muscle. Here, the shape of PQ was not similar to the normal morphology of the muscle. The PQ muscle appeared to be in distinct triangular-shaped instead of quadrangular-shaped. In addition, this triangular-shaped was found in two sites i.e. proximal and distal. Significantly, the PQ muscle consisted of two fleshy red fibres and white aponeurosis. Proximally placed portion had a wide base and a narrower apex. The larger base was attached to the ulna and formed of fleshy red fibres which converged laterally to be continuous with aponeurosis ending on the radius. In contrast, the distal triangular portion had the fleshy fibres attached to the radius and converged medially to be continuous with aponeurotic portions on the ulna. Each portion were referred as pronator triangularis proximalis and pronator triangularis distalis. These variations might affect atypically in cases of forearm pronation. Information of these variations is important in hand surgeries and provide an additional knowledge on the relationship between morphology of PQ muscle and the limitation or the strength in the action of it.
    Matched MeSH terms: Forearm
  8. Seto, Boon Chong, Moissinac, Kevin
    MyJurnal
    Accidental stab wounds caused by door handles are rare. A case is presented where a boy sustained a stab injury by a door handle with resultant impaction of the door handle into his forearm. The injury was possibly predisposed by the design of the door lock-and-handle complex and precipitated by his activity, both of which could have been avoided by a different design of the door lock and handle complex and perhaps closer supervision while at school.
    Matched MeSH terms: Forearm
  9. Selvanayagam VS, Riek S, DE Rugy A, Carroll TJ
    Med Sci Sports Exerc, 2016 09;48(9):1835-46.
    PMID: 27116648 DOI: 10.1249/MSS.0000000000000956
    PURPOSE: Goal-directed movements tend to resemble the characteristics of previously executed actions. Here we investigated whether a single bout of strength training, which typically involves stereotyped actions requiring strong neural drive, can bias subsequent aiming behavior toward the direction of trained forces.

    METHODS: In experiment 1 (n = 10), we tested the direction of force exerted in an isometric aiming task before and after 40 repetitions of 2-s maximal-force ballistic contractions toward a single directional target. In experiment 2 (n = 12), each participant completed three training conditions in a counterbalanced crossover design. In two conditions, both the aiming task and the training were conducted in the same (neutral) forearm posture. In one of these conditions, the training involved weak forces to determine whether the level of neural drive during training influences the degree of bias. In the third condition, high-force training contractions were performed in a 90° pronated forearm posture, whereas the low-force aiming task was performed in a neutral forearm posture. This dissociated the extrinsic training direction from the pulling direction of the trained muscles during the aiming task.

    RESULTS: In experiment 1, we found that aiming direction was biased toward the training direction across a large area of the work space (approximately ±135°; tested for 16 targets spaced 22.5° apart), whereas in experiment 2, we found systematic bias in aiming toward the training direction defined in extrinsic space, but only immediately after high-force contractions.

    CONCLUSION: Our findings suggest that bias effects of training involving strong neural drive generalize broadly to untrained movement directions and are expressed according to extrinsic rather than muscle-based coordinates.

    Matched MeSH terms: Forearm/physiology
  10. Pan KL, Masbah O, Razak M
    Med J Malaysia, 2000 Jun;55(2):268-70.
    PMID: 19839159
    A rare combination of a segmental ulnar fracture with fracture dislocation of the head of the radius and intraarticular fracture of the distal radius concomitant with an ipsilateral scaphoid, lunate and coronoid process fractures is presented. The mechanism of injury could possibly be a tremendous impact on the outstretched hand with a dorsiflexed wrist, fracturing the carpal bones and the distal radius. Transmitted axial forces on the ulna in a pronating forearm resulted in the other fractures. To the best of our knowledge, no such case has been reported. Open reduction with screw fixation of the scaphoid, plating of the proximal ulna and Kirschner wiring of the distal radius and radial head dislocation were done.
    Matched MeSH terms: Forearm Injuries*
  11. Yammine K, Erić M
    Phlebology, 2017 Jul;32(6):403-414.
    PMID: 27343223 DOI: 10.1177/0268355516655670
    Background The aim of this systematic review is to quantitatively synthesize evidence on the prevalence of superficial vein patterns in the cubital region. Method A systematic literature search was conducted through a number of electronic databases. We identified 27 studies, including 9924 arms, which met the inclusion criteria. Results Meta-analysis showed that "N" shaped arrangement type was the commonest pattern (≈44-60%) followed by "M" shaped arrangement (≈20-25%). The prevalence of "M" type and "M"-like type was significantly higher in males, whereas females showed a significant predominance of "I" or "O" type. No significant differences in various pattern types were found for laterality. The frequency of "M" type is significantly lesser in Indian and Japanese populations, but they have significantly higher frequency of "N" type. In Malay population, "I" or "O" type was significantly higher, while the brachial CV was poorly developed or missing significantly in Indian population. Conclusion This evidence-based clinical anatomy review contributes to our anatomical knowledge regarding the true prevalence of pattern types of the superficial veins in cubital region in humans and, subsequently, might help in performing safer venous access and more direct approaches to these veins, especially under emergency conditions.
    Matched MeSH terms: Forearm/blood supply*
  12. Uwamahoro R, Sundaraj K, Feroz FS
    Sensors (Basel), 2023 Sep 29;23(19).
    PMID: 37836995 DOI: 10.3390/s23198165
    Neuromuscular electrical stimulation plays a pivotal role in rehabilitating muscle function among individuals with neurological impairment. However, there remains uncertainty regarding whether the muscle's response to electrical excitation is affected by forearm posture, joint angle, or a combination of both factors. This study aimed to investigate the effects of forearm postures and elbow joint angles on the muscle torque and MMG signals. Measurements of the torque around the elbow and MMG of the biceps brachii (BB) muscle were conducted in 36 healthy subjects (age, 22.24 ± 2.94 years; height, 172 ± 0.5 cm; and weight, 67.01 ± 7.22 kg) using an in-house elbow flexion testbed and neuromuscular electrical stimulation (NMES) of the BB muscle. The BB muscle was stimulated while the forearm was positioned in the neutral, pronation, or supination positions. The elbow was flexed at angles of 10°, 30°, 60°, and 90°. The study analyzed the impact of the forearm posture(s) and elbow joint angle(s) on the root-mean-square value of the torque (TQRMS). Subsequently, various MMG parameters, such as the root-mean-square value (MMGRMS), the mean power frequency (MMGMPF), and the median frequency (MMGMDF), were analyzed along the longitudinal, lateral, and transverse axes of the BB muscle fibers. The test-retest interclass correlation coefficient (ICC21) for the torque and MMG ranged from 0.522 to 0.828. Repeated-measure ANOVAs showed that the forearm posture and elbow flexion angle significantly influenced the TQRMS (p < 0.05). Similarly, the MMGRMS, MMGMPF, and MMGMDF showed significant differences among all the postures and angles (p < 0.05). However, the combined main effect of the forearm posture and elbow joint angle was insignificant along the longitudinal axis (p > 0.05). The study also found that the MMGRMS and TQRMS increased with increases in the joint angle from 10° to 60° and decreased at greater angles. However, during this investigation, the MMGMPF and MMGMDF exhibited a consistent decrease in response to increases in the joint angle for the lateral and transverse axes of the BB muscle. These findings suggest that the muscle contraction evoked by NMES may be influenced by the interplay between actin and myosin filaments, which are responsible for muscle contraction and are, in turn, influenced by the muscle length. Because restoring the function of limbs is a common goal in rehabilitation services, the use of MMG in the development of methods that may enable the real-time tracking of exact muscle dimensional changes and activation levels is imperative.
    Matched MeSH terms: Forearm/physiology
  13. Tan CK, Huang YQ, Yap KB
    Med J Malaysia, 2013 Oct;68(5):443-4.
    PMID: 24632878
    Vancomycin has been documented to cause various adverse cutaneous reactions. We present a case report of a man, who developed a large localized erythematous plaque in his forearm following parenteral vancomycin therapy. We believe this to be the first reported case of such cutaneous reaction associated with parenteral vancomycin therapy.
    Matched MeSH terms: Forearm
  14. Choo C, Wong H, Nordin A
    Malays Orthop J, 2012 Nov;6(3):57-9.
    PMID: 25279061 MyJurnal DOI: 10.5704/MOJ.1207.008
    Shoulder girdle injuries after high energy traumatic impacts to the shoulder have been well documented. Based on the series of 1603 injuries of the shoulder girdle reported by Cave and colleagues, 85% of the dislocations were glenohumeral, 12% acromioclavicular and 3% sternoclavicular (1). Less frequently described are injuries involving both the sternoclavicular and acromioclavicular joints simultaneously in one extremity. The present report discusses a case of traumatic floating clavicle associated with ipsilateral forearm and wrist injury which was treated surgically.
    Matched MeSH terms: Forearm
  15. Manohar, A., Ramal, L.
    MyJurnal
    Palmaris longus is tendon of choice in reconstructive, plastic and cosmetic surgeries. Thus, a suitable length is required and it would be more convenient if the length of the tendon of the palmaris longus could be estimated before harvesting. This study was carried out to determine the relationship between the length and width of the palmaris longus tendon and the length of forearm and hand, the relationship between the length and the width of the palmaris longus tendon and wrist width and wrist circumference, as well as to identify a technique to estimate the length of the tendinous part of palmaris longus before harvesting it. A standardized proforma was used to collect the data of each of the 31 cadavers upper limbs. These data were analysed using SPSS software version 17. It is important to note that p value less than 0.05 is considered as statistically significant in this study. Out of the 31 upper limbs, palmaris longus tendon was absent in 3 (9.68%). Meanwhile, the mean length and width of the palmaris longus tendon was found to be 16.20 cm and 0.48 cm, respectively. The mean length of the forearm and hand was 26.6 cm and 21.2 cm, respectively. The mean width of the wrist and wrist circumference was 8.2 cm and 14.82 cm, respectively. These indicate a significant and moderate relationship between the length of palmaris longus tendon and the length of forearm (r = 0.49, r2 = 0.24, p < 0.01). In addition, there was also a significant relationship between the length of palmaris longus tendon and the length of hand (r = 0.56, p < 0.01). This paper presents the technique used to estimate the length and width of the tendinous part of palmaris longus before harvesting. The length of palmaris longus can be estimated pre-operatively by measuring the length of the hand by using the technique explained in this paper.
    Matched MeSH terms: Forearm
  16. Rao M, Ashwini LS, Somayaji SN, Mishra S, Guru A, Rao A
    Oman Med J, 2011 Nov;26(6):e027.
    PMID: 28861181 DOI: 10.5001/omj.2011.120
    Variation in the origin of long flexor tendons in the anterior compartment of forearm is common. During routine cadaveric dissection at Melaka Manipal Medical College (Manipal Campus), we observed a separate muscle belly and tendon of flexor digitorum superficialis (FDS) to the fifth digit in the right upper limb of a 60 year-old male cadaver. The anomalous muscle belly originated from the common flexor tendon from the medial epicondyle of the humerus and continued as a thin tendon at the middle of the forearm to get inserted into the middle phalanx of the fifth digit. This can be considered as a case of split flexor digitorum superficialis. Such muscle variations and knowledge of their frequency, appearance, and location can be helpful for surgeons.
    Matched MeSH terms: Forearm
  17. Das S, Paul S
    Clin Anat, 2008 Nov;21(8):805-6.
    PMID: 18651658 DOI: 10.1002/ca.20619
    Matched MeSH terms: Forearm/anatomy & histology; Forearm/innervation
  18. Abdelzaher E, Elwany A, Amr SA
    Malays J Pathol, 2018 Dec;40(3):355-358.
    PMID: 30580369
    Malignant peripheral nerve sheath tumour (MPNST) with perineurial differentiation is a rare variant of MPNST. The pathological features and clinical significance of this variant remain to be characterised. We reported the clinicoradiological and pathological features of a case of recurrent right arm mass related to the ulnar nerve in a 42-year-old female patient. On pathological examination, the tumour showed dual features of conventional and perineurial MPNST which was proven by positive immunostaining for S-100 and EMA. The pathological diagnosis was MPNST with perineurial differentiation. In addition, a peculiar and rare finding of intracytoplasmic eosinophilic hyaline globules (thanatosomes) within tumour cells is reported. We document a rare tumour with hybrid features between conventional and perineurial MPNSTs. Further studies are needed to establish its biological behaviour.
    Matched MeSH terms: Forearm/pathology*; Forearm/surgery
  19. Yammine K, Erić M
    Surg Radiol Anat, 2020 Mar;42(3):259-267.
    PMID: 31741040 DOI: 10.1007/s00276-019-02381-x
    INTRODUCTION: The tendon of the palmaris longus is commonly used as a tendon graft in many reconstructive surgeries. Easy to access and at proximity to the hand, the palmaris longus tendon is considered as the optimal tendon source for hand reconstructive surgery. However, and besides its inconsistency, the size of the palmaris longus tendon is reported to show variability. The aim of this study is to look for the surgical adequacy of the palmaris longus tendon by conducting a quantitative synthesis on its length and width in human populations and its correlation with the forearm length.

    METHODS: Twenty-four studies met the inclusion criteria including 1761 cadaveric limbs.

    RESULTS: The results were as following: (a) the mean palmaris longus tendon length was of 13.9 ± 2.6 cm, (b) the mean ratio palmaris longus tendon length/forearm length was of 0.545 ± 0.06, (c) the weighted correlation value was of 0.686, and (d) the mean palmaris longus tendon width was of 4.0 ± 1.7 mm. Only five studies reported a palmaris longus tendon length of more than 15 cm. The palmaris longus tendon length was shown to vary between ancestries; the Japanese had the shortest while Malaysian the longest palmaris longus tendons. All studies but one reported a palmaris longus tendon mean width of more than 3 mm where the minimal mean palmaris longus tendon width was of 2.5 mm.

    CONCLUSION: While the requested length depends on the recipient site and/or type of reconstructive surgery, the palmaris longus tendon often met the required diameter for grafting. Our review demonstrated that while palmaris longus length varies between ancestries, its width is often adequate for grafting. In addition, the forearm length could be a good predictor of palmaris longus tendon length; such correlation could assist surgeons when planning to use palmaris longus tendon as a graft source.

    Matched MeSH terms: Forearm/anatomy & histology*; Forearm/surgery
  20. Yvonne-Tee GB, Rasool AH, Halim AS, Rahman AR
    J Pharmacol Toxicol Methods, 2005 Sep-Oct;52(2):286-92.
    PMID: 16125628
    Postocclusive reactive hyperemia in forearm skin is a commonly used model for studying microvascular reactivity function, particularly in the assessment of vascular effect of topically applied pharmacological substances. In this study, we investigated the reproducibility of several different laser-Doppler-derived parameters in the measurement of postocclusive reactive hyperemia at forearm skin in healthy subjects.
    Matched MeSH terms: Forearm/blood supply; Forearm/physiopathology*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links