Displaying publications 1 - 20 of 38 in total

Abstract:
Sort:
  1. Barry OM, Ali F, Ronderos M, Sudhaker A, Kumar RK, Mood MC, et al.
    Catheter Cardiovasc Interv, 2021 01 01;97(1):127-134.
    PMID: 32294315 DOI: 10.1002/ccd.28908
    OBJECTIVES: To describe the development of a quality collaborative for congenital cardiac catheterization centers in low and middle-income countries (LMICs) including pilot study data and a novel procedural efficacy measure.

    BACKGROUND: Absence of congenital cardiac catheterization registries in LMICs led to the development of the International Quality Improvement Collaborative Congenital Heart Disease Catheterization Registry (IQIC-CHDCR). As a foundation for this initiative, the IQIC is a collaboration of pediatric cardiac surgical programs from LMICs. Participation in IQIC has been associated with improved patient outcomes.

    METHODS: A web-based registry was designed through a collaborative process. A pilot study was conducted from October through December 2017 at seven existing IQIC sites. Demographic, hemodynamic, and adverse event data were obtained and a novel tool to assess procedural efficacy was applied to five specific procedures. Procedural efficacy was categorized using ideal, adequate, and inadequate.

    RESULTS: A total of 429 cases were entered. Twenty-five adverse events were reported. The five procedures for which procedural efficacy was measured represented 48% of cases (n = 208) and 71% had complete data for analysis (n = 146). Procedure efficacy was ideal most frequently in patent ductus arteriosus (95%) and atrial septal defect (90%) device closure, and inadequate most frequently in coarctation procedures (100%), and aortic and pulmonary valvuloplasties (50%).

    CONCLUSIONS: The IQIC-CHDCR has designed a feasible collaborative to capture catheterization data in LMICs. The novel tool for procedural efficacy will provide valuable means to identify areas for quality improvement. This pilot study and lessons learned culminated in the full launch of the IQIC-CHDCR.

    Matched MeSH terms: Cardiac Catheterization/adverse effects
  2. Holzer RJ, Bergersen L, Thomson J, Aboulhosn J, Aggarwal V, Akagi T, et al.
    JACC Cardiovasc Interv, 2024 Jan 22;17(2):115-216.
    PMID: 38099915 DOI: 10.1016/j.jcin.2023.11.001
    Matched MeSH terms: Cardiac Catheterization/adverse effects
  3. Leong MC, Hoo XY, Alwi M
    Cardiol Young, 2024 Jan;34(1):228-231.
    PMID: 38073568 DOI: 10.1017/S1047951123004055
    Amplatzer Vascular Plug IV (Abbott, USA) is usually used for the occlusion of abnormal tortuous vessels and has not been tried for the transcatheter closure of perimembranous ventricular septal defects with wind-sock morphology. Here, we report on three successful cases of perimembranous ventricular septal defect transcatheter closure using Amplatzer Vascular Plug IV. We did not observe residual shunting or new onset of complications during follow up. These preliminary positive results advocate the application and suitability of Amplatzer Vascular Plug IV for closing wind-sock-like perimembranous ventricular septal defects.
    Matched MeSH terms: Cardiac Catheterization/methods
  4. Sulieman A, Mayhoub F, Ibrahim HS, Omer H, Alkhorayef M, Abolaban FA, et al.
    Radiat Prot Dosimetry, 2021 Oct 12;195(3-4):314-318.
    PMID: 34265851 DOI: 10.1093/rpd/ncab107
    The objective of this study is to estimate the annual effective dose for cardiologists and nurses by measuring Hp(10) and Hp(0.07) during cardiac catheterization procedures. A total of 16 staffs members were working in interventional cardiology during 1 year at a tertiary hospital. The occupational dose was measured using calibrated thermo-luminescent dosemeters (TLD-100, LiF:Mg,Ti). The overall mean and range of the annual Hp(10) and Hp(0.07) (mSv) for cardiologists were 3.7 (0.13-14.5) and 3.2 (0.21-14.7), respectively. Cardiologists were frequently exposed to higher doses compared with nurses and technologists. The exposure showed wide variations, which depend on occupation and workload. Staff is adhered to radiation protection guidelines regarding shielding the trunk, thyroid shield, thus appropriately protected. Lens dose measurement is recommended to ensure that dose limit is not exceeded.
    Matched MeSH terms: Cardiac Catheterization
  5. Latiff HA, Samion H, Kandhavel G, Aziz BA, Alwi M
    Cardiol Young, 2001 Mar;11(2):201-4.
    PMID: 11293739
    BACKGROUND: From January, 1997, as part of an international multicentric trial, we have been closing small-to-moderate atrial septal defects within the oval fossa using the Amplatzer Septal Occluder (ASO, AGA Medical).

    METHODS: All patients with defects within the oval fossa deemed potentially suitable for transcatheter closure were investigated by transesophageal echocardiography with the aim of gaining extra information that might alter the decision to use the device to close the defect. Views were obtained in transverse and longitudinal planes, permitting measurements of the diameter of the defect, and its distance from the atrioventricular valves, coronary sinus, and pulmonary veins. Additionally, we sought to identify multiple defects, and to exclude sinus venosus defects.

    RESULTS: Of 56 patients with left-to-right shunts, 41 (73.2%) were deemed suitable for closure with the Amplatzer Septal Occluder. All underwent the procedure successfully, with no complications. This includes 5 patients with multiple small defects that were sufficiently close to the main defect to be closed with a single device. Only two of these had been detected on the transthoracic study. In the remaining 15 of 56 patients, transcatheter closure was deemed unsuitable. In 9 patients, this was due to the limitation of the size of the device available during the period of study, this representing a relative contraindication. In the remaining 6 (10.7%), transcatheter closure was not performed because multiple defects were too far apart to be closed with a single device in 3 patients, two patients were noted to have a sinus venosus defect, and another was noted to have anomalous connection of the right upper pulmonary vein to the right atrium. Excluding patients contraindicated due to the size of the defect alone, transesophageal echocardiography provided extra information in one-tenth of our patients, which altered the decision regarding management.

    CONCLUSION: Transesophageal echocardiography is indispensable in the evaluation of patients undergoing transcatheter closure of atrial septal defect.

    Matched MeSH terms: Cardiac Catheterization/methods*
  6. Alwi M, Kang LM, Samion H, Latiff HA, Kandavel G, Zambahari R
    Am J Cardiol, 1997 May 15;79(10):1430-2.
    PMID: 9165178 DOI: 10.1016/s0002-9149(97)00160-4
    Two hundred eleven patients with small- to moderate-sized native patent ductus arteriosus underwent closure using Gianturco coils, employing the transvenous multiple catheter approach. Short-term results showed a high rate of complete occlusion and a potential long-term complication of mild left pulmonary artery stenosis in a small number of patients.
    Matched MeSH terms: Cardiac Catheterization*
  7. Abrahamyan L, Barker M, Dharma C, Lee DS, Austin PC, Asghar A, et al.
    Int J Cardiol, 2023 Jan 15;371:109-115.
    PMID: 36165815 DOI: 10.1016/j.ijcard.2022.09.033
    BACKGROUND: Patent foramen ovale (PFO) is a congenital heart defect associated with an increased risk of cryptogenic stroke. We aimed to evaluate real-world outcomes of adult patients undergoing transcatheter PFO closure with the Amplatzer PFO Occluder.

    METHODS: In this single centre, retrospective cohort study, we linked a detailed clinical registry with provincial administrative databases to obtain short and long-term outcomes. Validated algorithms were used to established baseline comorbidities and adverse outcomes.

    RESULTS: Between 1999 and 2017, 479 patients had PFO closure with an Amplatzer PFO Occluder. The average age of the patients was 47.3 years (standard deviation (SD) = 12.4), and 54.7% were males. The procedural success was 100%, and 96% of patients were discharged on the same day. Any in-hospital complication was observed in 2.5% (n = 12) of patients. At 30 days post-discharge, 18% of patients had an ED visit and 5% a hospitalization. Over a mean follow-up of 9.1 (SD = 3.8) years, 4% experienced TIA, 1.5% stroke, and 7.6% atrial fibrillation. The composite outcome of stroke/TIA/death was observed in 10.9% of patients (1.22 events per 100 person-years). Patients >60 years old experienced higher rates of adverse events than younger patients.

    CONCLUSIONS: In this large real-world cohort of patients with cryptogenic stroke, we observed excellent safety and effectiveness outcomes for PFO closure conducted with Amplatzer PFO Occluder, similar to randomized controlled trials or other long-term cohort studies. New onset atrial fibrillation was one of the most commonly adverse events. Future studies should investigate early post-discharge management of patients to prevent readmissions.

    Matched MeSH terms: Cardiac Catheterization/adverse effects
  8. Munhoz D, Collet C, Mizukami T, Yong A, Leone AM, Eftekhari A, et al.
    Am Heart J, 2023 Nov;265:170-179.
    PMID: 37611857 DOI: 10.1016/j.ahj.2023.07.016
    INTRODUCTION: Diffuse disease has been identified as one of the main reasons leading to low post-PCI fractional flow reserve (FFR) and residual angina after PCI. Coronary pressure pullbacks allow for the evaluation of hemodynamic coronary artery disease (CAD) patterns. The pullback pressure gradient (PPG) is a novel metric that quantifies the distribution and magnitude of pressure losses along the coronary artery in a focal-to-diffuse continuum.

    AIM: The primary objective is to determine the predictive capacity of the PPG for post-PCI FFR.

    METHODS: This prospective, large-scale, controlled, investigator-initiated, multicenter study is enrolling patients with at least 1 lesion in a major epicardial vessel with a distal FFR ≤ 0.80 intended to be treated by PCI. The study will include 982 subjects. A standardized physiological assessment will be performed pre-PCI, including the online calculation of PPG from FFR pullbacks performed manually. PPG quantifies the CAD pattern by combining several parameters from the FFR pullback curve. Post-PCI physiology will be recorded using a standardized protocol with FFR pullbacks. We hypothesize that PPG will predict optimal PCI results (post-PCI FFR ≥ 0.88) with an area under the ROC curve (AUC) ≥ 0.80. Secondary objectives include patient-reported and clinical outcomes in patients with focal vs. diffuse CAD defined by the PPG. Clinical follow-up will be collected for up to 36 months, and an independent clinical event committee will adjudicate events.

    RESULTS: Recruitment is ongoing and is expected to be completed in the second half of 2023.

    CONCLUSION: This international, large-scale, prospective study with pre-specified powered hypotheses will determine the ability of the preprocedural PPG index to predict optimal revascularization assessed by post-PCI FFR. In addition, it will evaluate the impact of PPG on treatment decisions and the predictive performance of PPG for angina relief and clinical outcomes.

    Matched MeSH terms: Cardiac Catheterization/methods
  9. Yew KL
    Int J Cardiol, 2014 Dec 20;177(3):1127-8.
    PMID: 25150482 DOI: 10.1016/j.ijcard.2014.08.056
    Matched MeSH terms: Cardiac Catheterization/adverse effects*; Cardiac Catheterization/instrumentation
  10. Tay E, Muda N, Yap J, Muller DW, Santoso T, Walters DL, et al.
    Catheter Cardiovasc Interv, 2016 Jun;87(7):E275-81.
    PMID: 26508564 DOI: 10.1002/ccd.26289
    OBJECTIVES: The objective of this study is to describe and compare the use of the MitraClip therapy in mitral regurgitation (MR) patients with degenerative MR (DMR) and functional MR (FMR).

    INTRODUCTION: Percutaneous edge-to-edge repair of severe MR using the MitraClip device is approved for use in the USA for high risk DMR while European guidelines include its use in FMR patients as well.

    METHODS: The MitraClip in the Asia-Pacific Registry (MARS) is a multicenter retrospective registry, involving eight sites in five Asia-Pacific countries. Clinical and echocardiographic characteristics, procedural outcomes and 1-month outcomes [death and major adverse events (MAE)] were compared between FMR and DMR patients treated with the MitraClip.

    RESULTS: A total of 163 patients were included from 2011 to 2014. The acute procedural success rates for FMR (95.5%, n = 84) and DMR (92%, n = 69) were similar (P = 0.515). 45% of FMR had ≥2 clips inserted compared to 60% of those with DMR (P = 0.064).The 30-day mortality rate for FMR and DMR was similar at 4.5% and 6.7% respectively (P = 0.555). The 30-day MAE rate was 9.2% for FMR and 14.7% for DMR (P = 0.281). Both FMR and DMR patients had significant improvements in the severity of MR and NYHA class after 30 days. There was a significantly greater reduction in left ventricular end-diastolic diameter (P = 0.002) and end systolic diameter (P = 0.017) in DMR than in FMR.

    CONCLUSIONS: The MitraClip therapy is a safe and efficacious treatment option for both FMR and DMR. Although, there is a significantly greater reduction in LV volumes in DMR, patients in both groups report clinical benefit with improvement in functional class. © 2015 Wiley Periodicals, Inc.

    Matched MeSH terms: Cardiac Catheterization/adverse effects; Cardiac Catheterization/instrumentation*
  11. Alwi M, Budi RR, Mood MC, Leong MC, Samion H
    Cardiol Young, 2013 Apr;23(2):197-202.
    PMID: 22640635 DOI: 10.1017/S1047951112000595
    Objective: To determine the feasibility and safety of the Conquest Pro wire as an alternative to radiofrequency wire for perforation of atretic pulmonary valve and subsequent balloon dilatation and patent ductus arteriosus stenting in patients with pulmonary atresia with intact ventricular septum.
    Background: Radiofrequency valvotomy and balloon dilatation has become the standard of care for pulmonary atresia with intact ventricular septum in many institutions today.
    Methods: We report eight consecutive patients in whom we used the Conquest Pro coronary guidewire, a stiff wire normally reserved for revascularisation of coronary lesions with chronic total occlusion, for perforation of atretic pulmonary valve and subsequent balloon dilatation, and stenting of the patent ductus arteriosus.
    Results: Perforation of atretic pulmonary valve was successful in seven out of eight cases. Radiofrequency valvotomy was employed after failure of perforation by the Conquest Pro wire in one case where the right ventricular outflow tract was broad based and tapered towards the pulmonary valve, and was heavily trabeculated. Failure of the Conquest Pro wire to perforate the pulmonary valve plate was mainly attributed by the failure to engage the wire at the correct position.
    Conclusion: The Conquest Pro wire for perforation and subsequent interventions in the more straightforward cases of pulmonary atresia with intact ventricular septum is effective and safe, simplifying the entire procedure. However, the radiofrequency generator and wires remain essential tools in the paediatric interventional catheter laboratory.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*; Cardiac Catheterization/methods
  12. Schramm J, Sivalingam S, Moreno GE, Thanh DQL, Gauvreau K, Doherty-Schmeck K, et al.
    Children (Basel), 2021 Mar 06;8(3).
    PMID: 33800765 DOI: 10.3390/children8030198
    Pulmonary vein stenosis (PVS) is a rare, but high mortality and resource intensive disease caused by mechanical obstruction or intraluminal myofibroproliferation, which can be post-surgical or idiopathic. There are increasing options for management including medications, cardiac catheterization procedures, and surgery. We queried the International Quality Improvement Collaborative for Congenital Heart Disease (IQIC) database for cases of PVS and described the cohort including additional congenital lesions and surgeries as well as infectious and mortality outcomes. IQIC is a quality improvement project in low-middle-income countries with the goal of reducing mortality after congenital heart surgery. Three cases were described in detail with relevant images. We identified 57 cases of PVS surgery, with similar mortality to higher income countries. PVS should be recognized as a global disease. More research and collaboration are needed to understand the disease, treatments, and outcomes, and to devise treatment approaches for low resource environments.
    Matched MeSH terms: Cardiac Catheterization
  13. Latiff HA, Alwi M, Kandhavel G, Samion H, Zambahari R
    Ann Thorac Surg, 1999 Oct;68(4):1400-1.
    PMID: 10543517
    A 10-month-old boy underwent operation to close a large secundum atrial septal defect and multiple muscular ventricular septal defects. Closure of the ventricular septal defects was unsuccessful and led to worsening cardiac failure and inability to wean the patient from mechanical ventilation. Transcatheter closure of the ventricular septal defects using Gianturco coils was undertaken. This technique is an effective alternative for closure of multiple muscular ventricular septal defects in infants and small children.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  14. Ramasamy D, Zambahari R, Fu M, Yeh KH, Hung JS
    Cathet Cardiovasc Diagn, 1993 Sep;30(1):40-4.
    PMID: 8402863
    Because transseptal catheterization is felt to be contraindicated in patients with severe kyphoscoliosis, there have been no reports of percutaneous transvenous mitral commissurotomy performed in such patients. This report describes percutaneous transvenous mitral commissurotomy in three patients with severe thoracic kyphoscoliosis, with special emphasis on the transseptal puncture technique. Biplane right atrial angiography and the contrast septal flush method are very useful in landmark selection for a safe transseptal puncture.
    Matched MeSH terms: Cardiac Catheterization/methods*
  15. Fong Chee Yee, Masduki A, Hitam O
    Med J Malaysia, 1988 Dec;43(4):302-10.
    PMID: 3241595
    Matched MeSH terms: Cardiac Catheterization/statistics & numerical data*
  16. Bilkis AA, Alwi M, Hasri S, Haifa AL, Geetha K, Rehman MA, et al.
    J Am Coll Cardiol, 2001 Jan;37(1):258-61.
    PMID: 11153748 DOI: 10.1016/s0735-1097(00)01094-9
    Objectives: The aim of the study was to assess the safety and efficacy of the Amplatzer ductal occluder (ADO) in transcatheter occlusion of patent ductus arteriosus (PDA).
    Background: Transcatheter closure of small to moderate sized PDAs is an established procedure. The ADO is a self-expandable device with a number of salutary features, notably its retrievability, ease of delivery via small 5F to 7F catheters and a range of sizes suitable even for the larger PDAs.
    Methods: Between November 1997 and August 1999, the ADO was successfully implanted in 205 of 209 patients with PDA. The inclusion criteria for this device occlusion method were patients with clinical and echocardiographic features of moderate to large PDA, weighing > or =3.5 kg as well as asymptomatic adolescents and adults with PDA measuring > or =5.0 mm on two-dimensional (2D) echocardiogram. Occlusion was achieved via the antegrade venous approach. Follow-up evaluations were performed with 2D echocardiogram, color-flow mapping and Doppler measurement of the descending aorta and left pulmonary artery velocity at 24 h and 1, 3, 6 and 12 months after implantation.
    Results: Two hundred and five patients had successful PDA occlusion using this device. The patients were between two months and 50 years (median 1.9) and weighed between 3.4 kg and 63.2 (median 8.4). Infants made up 26% of the total patients. The PDA measured from 1.8 to 12.5 mm (mean 4.9) at the narrowest diameter. Forty-four percent of patients achieved immediate complete occlusion. On color Doppler the closure rates at 24 h and 1 month after implant were 66% and 97%, respectively. At 6 and 12 months all except one patient attained complete occlusion. Device embolization occurred in three patients; in two this was spontaneous, and in the other it was due to catheter manipulation during postimplant hemodynamic measurement. Mild aortic narrowing was seen in an infant.
    Conclusions: Patent ductus arteriosus occlusion using ADO is safe and efficacious. It is particularly useful in symptomatic infants and small children with relatively large PDA. Embolization can be minimized by selection of appropriate sized devices, and caution should be exercised in infants <5 kg.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  17. Yew KL, Razali F
    Int J Cardiol, 2015 Jun 1;188:56-7.
    PMID: 25885752 DOI: 10.1016/j.ijcard.2015.04.040
    Matched MeSH terms: Cardiac Catheterization/adverse effects*; Cardiac Catheterization/methods
  18. Latiff HA, Alwi M, Samion H, Kandhavel G
    Cardiol Young, 2002 May;12(3):224-8.
    PMID: 12365167
    This study reviewed the short-term outcome of transcatheter closure of the defects within the oval fossa using an Amplatzer Septal Occluder. From January 1997 to December 2000, 210 patients with defects within the oval fossa underwent successful transcatheter closure. We reviewed a total of 190 patients with left-to-right shunts, assessing the patients for possible complications and the presence of residual shunts using transthoracic echocardiogram at 24 h, 1 month, 3 months and one year. Their median age was 10 years, with a range from 2 to 64 years, and their median weight was 23.9 kg, with a range from 8.9 to 79 kg. In 5 patients, a patent arterial duct was closed, and in 2 pulmonary balloon valvoplasty performed, at the same sitting. The median size of the Amplatzer device used was 20 mm, with a range from 9 to 36 mm. The median times for the procedure and fluoroscopy were 95 min, with a range from 30 to 210 min, and 18.4 min, with a range from 5 to 144 min, respectively. Mean follow-up was 20.8 +/- 12.4 months. Complete occlusion was obtained in 168 of 190 (88%) patients at 24 h, 128 of 133 (96.2%) at 3 months, and 103 of 104 (99%) at one year. Complications occurred in 4 (2.1%) patients. In one, the device became detached, in the second the device embolized into the right ventricular outflow tract, the lower end of the device straddled in the third, and the final patient had significant bleeding from the site of venupuncture. There were no major complications noted on follow-up. We conclude that transcatheter closure of defects within the oval fossa using the Amplatzer Septal Occluder is safe and effective. Long-term follow-up is required, nonetheless, before it is recommended as a standard procedure.
    Matched MeSH terms: Cardiac Catheterization/adverse effects; Cardiac Catheterization/instrumentation*
  19. Zanjani KS, Wong AR, Sadiq M, Weber HS, Cutler NG
    Congenit Heart Dis, 2010 Sep-Oct;5(5):439-43.
    PMID: 21087429 DOI: 10.1111/j.1747-0803.2010.00448.x
    Objectives: There is little evidence in the medical literature about safety of PDA device closure and its effects on aortic root diameter in Marfan patients. We reported on nine Marfan patients whose ducts were occluded by coil or Amplatzer Duct Occluder.
    Patients and interventions: Two patients had aneurismal type E ducts which were closed by a single coil, respectively. The others had conical ducts for which even Amplatzer occluder, stiff, or double coils were used.
    Results: No untoward consequence was found during a median follow up period of 18.5 months (range 3 months to 6.33 years). Two patients had small residual shunts. The observed change in the mean ratio of aortic root diameter to its estimated value was statistically insignificant in seven patients who had complete data on their aortic root diameter before PDA closure and during the follow up.
    Conclusions: We concluded that PDA device closure in Marfan patients is safe. Risk of residual shunt is higher even after closure of small ducts.
    Matched MeSH terms: Cardiac Catheterization/adverse effects; Cardiac Catheterization/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links