Displaying all 8 publications

Abstract:
Sort:
  1. Hazwan Ab. Wahid, Kow, Ren Yi, Khan, Ed Simor, Komahen, Colin
    MyJurnal
    The occurrence of atlantoaxial rotatory subluxation is fairly uncommon; however, it is
    more common to be encountered in the paediatric population, typically seen after a
    retropharyngeal inflammation or after a minor trauma. Ligamentous laxity, shallower
    and more horizontally oriented facet joints especially at the C1-2 joint making them
    prone to have atlantoaxial subluxation or dislocation. (Copied from article).
    Matched MeSH terms: Zygapophyseal Joint
  2. Yusof MI, Shif M, Abdullah MS
    Malays Orthop J, 2015 Mar;9(1):4-10.
    PMID: 28435587 MyJurnal DOI: 10.5704/MOJ.1503.015
    This study was to evaluate the morphological features of degenerative spinal stenosis and adequacy of lateral canal stenosis decompression via unilateral and bilateral laminectomy. Measurements of facet joint angulation (FJA), mid facet point (MFP), mid facet point distance (MFPD), the narrowest point of the lateral spinal canal (NPLC) and the narrowest point of the lateral spinal canal distance (NPLCD) were performed. At L4L5 of the right and left side, the mean distance between the lateral border of the dura and MFP was 1.0 ± 0.2 cm and 1.0 ± 0.3cm respectively. The mean NPLC was seen at 0.7 ± 0.3 and 0.7 ± 0.3 cm cm from the dura. At L5S1 of the right and left side, the mean distance between the lateral border of the dura and MFP was 1.2± 0.2 and 1.3 ± 0.2 cm respectively. The mean NPLC was seen at 0.8 ± 0.4 and 0.9 ± 0.5 cm from the dura. Unilateral laminectomy may result in incomplete decompression.
    Matched MeSH terms: Zygapophyseal Joint
  3. Abd Latif MJ, Jin Z, Wilcox RK
    J Biomech, 2012 May 11;45(8):1346-52.
    PMID: 22483055 DOI: 10.1016/j.jbiomech.2012.03.015
    The spinal facet joints are known to be an important component in the kinematics and the load transmission of the spine. The articular cartilage in the facet joint is prone to degenerative changes which lead to back pain and treatments for the condition have had limited long term success. There is currently a lack of information on the basic biomechanical properties of the facet joint cartilage which is needed to develop tissue substitution or regenerative interventions. In the present study, the thickness and biphasic properties of ovine facet cartilage were determined using a combination of indentation tests and computational modelling. The equilibrium biphasic Young's modulus and permeability were derived to be 0.76±0.35 MPa and 1.61±1.10×10⁻¹⁵ m⁴/(Ns) respectively, which were within the range of cartilage properties characterised from the human synovial joints. The average thickness of the ovine facet cartilage was 0.52±0.10 mm, which was measured using a needle indentation test. These properties could potentially be used for the development of substitution or tissue engineering interventions and for computational modelling of the facet joint. Furthermore, the developed method to characterise the facet cartilage could be used for other animals or human donors.
    Matched MeSH terms: Zygapophyseal Joint/anatomy & histology; Zygapophyseal Joint/physiology*
  4. Lee W, Wong CC
    Global Spine J, 2021 Mar;11(2):256-265.
    PMID: 32875872 DOI: 10.1177/2192568220907574
    STUDY DESIGN: Systematic review.

    OBJECTIVE: Anterior-alone surgery has gained wider reception for subaxial cervical spine facets dislocation. Questions remain on its efficacy and safety as a stand-alone entity within the contexts of concurrent facet fractures, unilateral versus bilateral dislocations, anterior open reduction, and old dislocation.

    METHODS: A systematic review was performed with search strategy using translatable MESH terms across MEDLINE, EMBASE, VHL Regional Portal, and CENTRAL databases on patients with subaxial cervical dislocation intervened via anterior-alone approach. Two reviewers independently screened for eligible studies. PRISMA (Preferred Reporting Items for Systematic Review and Meta-Analysis) flow chart was adhered to. Nine retrospective studies were included. Narrative synthesis was performed to determine primary outcomes on spinal fusion and revisions and secondary outcomes on new occurrence or deterioration of neurology and infection rate.

    RESULTS: Nonunion was not encountered across all contexts. A total of 0.86% of unilateral facet dislocation (1 out of 116) with inadequate reduction due to facet fragments between the facet joints removed its malpositioned plate following fusion. No new neurological deficit was observed. Cases that underwent anterior open reduction did not encounter failure that require subsequent posterior reduction surgery. One study (N = 52) on old dislocation incorporated partial corpectomy in their approach and limited anterior-alone approach to cases with persistent instability.

    CONCLUSIONS: This systematic review supports the efficacy and success of anterior reduction, fusion, and instrumentation for cervical facet fracture dislocation. It is safe from a neurological standpoint. Revision rate due to concurrent facet fracture is low. Certain patients may require posteriorly based surgery or in specific cases combined anterior and posterior procedures.

    Matched MeSH terms: Zygapophyseal Joint
  5. Tan GH, Tan KK, Afian MS, Liew WF, Mohamad AR
    Med J Malaysia, 2005 Jul;60 Suppl C:111-3.
    PMID: 16381295
    We report a case of upper cervical instability associated with Down syndrome to highlight its potential progression to inflict cord compression and the rationale for surgical decompression and extended short segment occipito-axial fusion.
    Matched MeSH terms: Zygapophyseal Joint*
  6. Khoo C, Thevarayan S, Rengsen P, Deepak AS
    Malays Orthop J, 2010;4(2):48-50.
    MyJurnal
    We report a rare case of septic arthritis of the lumbar facet joint (SALFJ) with co-existing spondylolisthesis of the L5 on S1 vertebra and discuss possible differential diagnoses, diagnostic difficulties and management of this condition.
    Matched MeSH terms: Zygapophyseal Joint
  7. Yusof MI, Hassan E, Rahmat N, Yunus R
    Spine (Phila Pa 1976), 2009 Apr 1;34(7):713-7.
    PMID: 19333105 DOI: 10.1097/BRS.0b013e31819b2159
    Pedicle involvement in spinal tuberculosis (TB), the prevertebral abscess formation, severity of vertebral body, and disc collapse were evaluated from magnetic resonance imaging (MRI) of the patients.
    Matched MeSH terms: Zygapophyseal Joint/pathology; Zygapophyseal Joint/physiopathology
  8. Kosalishkwaran G, Parasuraman S, Singh DKJ, Natarajan E, Elamvazuthi I, George J
    Med Biol Eng Comput, 2019 Oct;57(10):2305-2318.
    PMID: 31444622 DOI: 10.1007/s11517-019-02026-6
    Degenerative disc disease (DDD) is a common condition in elderly population that can be painful and can significantly affect individual's quality of life. Diagnosis of DDD allows prompt corrective actions but it is challenging due to the absence of any symptoms at early stages. In studying disc degeneration, measurement of the range of motion (RoM) and loads acting on the spine are crucial factors. However, direct measurement of RoM involves increased instrumentation and risk. In this paper, an innovative method is proposed for calculating RoM, emphasizing repeatability and reliability by considering the posterior thickness of the spine. This is achieved by offsetting the position of markers in relation to the actual vertebral loci. Three geometrically identical finite element models of L3-L4 are developed from a CT scan with different types of elements, and thereafter, mesh element-related metrics are provided for the assessment of the quality of models. The model with the best mesh quality is used for further analysis, where RoM are within ranges as reported in literature and in vivo experiment results. Various kinds of stresses acting on individual components including facet joints are analysed for normal and abnormal loading conditions. The results showed that the stresses in abnormal load conditions for all components including cortical (76.67 MPa), cancellous (69.18 MPa), annulus (6.30 MPa) and nucleus (0.343 MPa) are significantly greater as compared to normal loads (49.96 MPa, 44.2 MPa, 4.28 MPa and 0.23 MPa respectively). However, stress levels for both conditions are within safe limits (167-215 MPa for cortical, 46 MPa for the annulus and 3 MPa for facets). The results obtained could be used as a baseline motion and stresses of healthy subjects based on their respective lifestyles, which could benefit clinicians to suggest corrective actions for those affected by DDD.
    Matched MeSH terms: Zygapophyseal Joint