  1. Arshad MKM, Adzhri R, Fathil MFM, Gopinath SCB, N M NM
    J Nanosci Nanotechnol, 2018 Aug 01;18(8):5283-5291.
    PMID: 29458578 DOI: 10.1166/jnn.2018.15419
    The development of electrical biosensor towards device miniaturization in order to achieve better sensitivity with enhanced electrical signal has certain limitations especially complexity in fabrication process and costs. In this paper, an alternative technique with minor modification in the device structure is presented for signal amplification by implementing ambipolar conduction in the biosensor itself. We demonstrated the field-effect transistor (FET)-based biosensor coupled back-gate for attaining a higher sensitivity with the detection of lower target abundance. To utilize the coupled back-gate as a pre-amplifier, silicon-on-insulator wafer with thicknesses of top-silicon and buried oxide (BOX) layers of 70 nm and 145 nm, respectively were desired. Titanium dioxide (TiO2) nanomaterial was deposited using sol-gel method on the channel which acts as a transducer. Surface functionalization on TiO2 thin film allowed an effective immobilization of anti-cardiac troponin I antibody to interact cardiac troponin I (cTnI). Binding events at each step was validated by X-ray photoelectron spectroscopy (XPS) analysis. Further, electrical characterization (Id-Vd) confirms the potentiality of FET-based biosensor to detect cTnI (represents acute myocardial infarction disease) with the concentration ranges from 10 μg/ml down to 1 fg/ml. The sensitivity of 459.2 nA (g/ml)-1 and lower detection limit of 1 fg/ml were achieved at Vbg = -5 V and Vd = 5 V. The designed device demonstrates its ability to detect lower level of cTnI with pre-amplified electrical signal by back-gate biasing.
    Matched MeSH terms: Troponin I/analysis*
  2. Kumar A, Sathian B
    Asian Pac J Trop Biomed, 2013 Jun;3(6):487-91.
    PMID: 23730563 DOI: 10.1016/S2221-1691(13)60101-X
    To study the usefulness of traditional lipid profile levels in screening subjects who had developed chest pain due to cardiac event as indicated by a positive troponin I test.
    Matched MeSH terms: Troponin I/blood*
  3. Fathil MF, Md Arshad MK, Gopinath SC, Hashim U, Adzhri R, Ayub RM, et al.
    Biosens Bioelectron, 2015 Aug 15;70:209-20.
    PMID: 25841117 DOI: 10.1016/j.bios.2015.03.037
    Acute myocardial infarction or myocardial infarction (MI) is a major health problem, due to diminished flow of blood to the heart, leads to higher rates of mortality and morbidity. Data from World Health Organization (WHO) accounted 30% of global death annually and expected more than 23 million die annually by 2030. This fatal effects trigger the need of appropriate biomarkers for early diagnosis, thus countermeasure can be taken. At the moment, the most specific markers for cardiac injury are cardiac troponin I (cTnI) and cardiac troponin T (cTnT) which have been considered as 'gold standard'. Due to higher specificity, determination of the level of cardiac troponins became a predominant indicator for MI. Several ways of diagnostics have been formulated, which include enzyme-linked immunosorbent assay, chemiluminescent, fluoro-immunoassays, electrical detections, surface plasmon resonance, and colorimetric protein assay. This review represents and elucidates the strategies, methods and detection levels involved in these diagnostics on cardiac superior biomarkers. The advancement, sensitivity, and limitations of each method are also discussed. In addition, it concludes with a discussion on the point-of care (POC) assay for a fast, accurate and ability of handling small sample measurement of cardiac biomarker.
    Matched MeSH terms: Troponin I/blood*
  4. Ravichandran J, Woon SY, Quek YS, Lim YC, Noor EM, Suresh K, et al.
    Am J Med, 2019 03;132(3):362-366.
    PMID: 30503877 DOI: 10.1016/j.amjmed.2018.11.017
    PURPOSE: The purpose of this study was to examine the association of circulating concentrations of high-sensitivity cardiac troponin I (hs-cTn) in the various trimesters of pregnancy in patients with and without hypertension.

    METHODS: This was a prospective cross-sectional study of pregnant and postnatal women aged between 18-35 years with no coexisting diseases. Serum samples were analysed for hs-TnI.

    RESULTS: A total of 880 women (mean age = 29.1 years [standard deviation = 5.1 years]) were recruited with 129 (14%), 207 (24%), and 416 (47%) patients in the first, second, and third trimesters, respectively. Ninety (10%) participants were recruited in the postnatal period. During pregnancy 28 (3%) patients were classified as having pregnancy-induced hypertension and 10 (1%) as preeclampsia. High-sensitivity cardiac troponin I was measurable in 546 (62%) participants with a median of 1 ng/L (range 0 to 783 ng/L). Troponin concentrations were above the 99th percentile in 19 (2%) individuals. Patients with pregnancy-induced hypertension and preeclampsia had higher concentrations of hs-TnI (median 11 ng/L [interquartile range (IQR) 6 to 22 ng/L] vs 12ng/L [IQR 3 to 98 ng/L] vs 1 ng/L [IQR 0 to 1 ng/L]). In logistic regression modeling hs-cTnI concentration remained an independent predictor of pregnancy-induced hypertension or preeclampsia in both unadjusted and adjusted models (odds ratio 9.3 [95% confidence interval 5.8 to 16.3] and 11.5 [95% confidence interval 6.3 to 24.1], respectively, per doubling of hs-TnI concentrations).

    CONCLUSIONS: Cardiac troponin measured using a high-sensitivity assay is quantifiable in the majority of young pregnant women with 2% of individuals having concentration above the 99th percentile sex-specific threshold. Patients with pregnancy-induced hypertension or preeclampsia had higher cardiac troponin concentrations. Cardiac troponin was a strong independent predictor of pregnancy-induced hypertension or preeclampsia in pregnant and postnatal women.

    Matched MeSH terms: Troponin I/blood*
  5. Sthaneshwar P, Jamaluddin FA, Fan YS
    Pathology, 2010;42(5):454-6.
    PMID: 20632822 DOI: 10.3109/00313025.2010.493861
    The aim of this study was to evaluate the distribution of cardiac troponin I (cTnI) values, measured by the ADVIA TnI-Ultra method in a multi-ethnic group and to determine the imprecision of the assay.
    Matched MeSH terms: Troponin I/blood*
  6. Taniselass S, Arshad MKM, Gopinath SCB, Fathil MFM, Ibau C, Anbu P
    Mikrochim Acta, 2021 07 15;188(8):257.
    PMID: 34268634 DOI: 10.1007/s00604-021-04922-x
    A label-free chemical bonding strategy mediated by reduced graphene oxide (rGO) basal plane functional groups has been developed for cardiac Troponin I (cTnI) detection. Four different chemical strategies on respective electrode sensing surface were precedingly examined using electrochemical impedance spectroscopy. The impedimetric assessment was carried out by sweeping frequency at the range 0.1-500 kHz perturbated at a small amplitude of AC voltage (25 mV). The chemical strategy-4 denoted as S-4 shows a significant analytical performance on cTnI detection in spiked buffer and human serum, whereby the pre-mixture of rGO and (3-Aminopropyl)triethoxysilane (APTES) creates a large number of amine sites (-NH2), which significantly enhanced the antibody immobilization without excessive functionalization. The as-fabricated immunosensor exhibited an ultra-low limit of detection of 6.3 ag mL-1 and the lowest antigen concentration measured was at 10 ag mL-1. The immunosensor showed a linear and wide range of cTnI detection (10 ag mL-1-100 ng mL-1) in human serum with a regression coefficient of 0.9716, rapid detection (5 min of binding time), and stable and highly reproducible bioelectrode response with RSD 
    Matched MeSH terms: Troponin I/blood*
  7. Loong CW, Firdaus MAM, Said MRM, Abidin IZ
    Medeni Med J, 2020;35(3):266-270.
    PMID: 33110680 DOI: 10.5222/MMJ.2020.47374
    Takotsubo syndrome is a rare disease and remained ambiguous with its etiology. The disease manifests in various clinical characteristics and even mimicking acute coronary syndrome. We are reporting a case of an elderly lady who manifested by unsteady gaits and recurrent falls. Subacute infarct of the right corona radiata was observed on the brain CT. In addition, coronary angiography and ventriculogram were performed because of dynamic ECG changes and elevated troponin I levels. The angiogram was normal while ventriculogram showed apical ballooning. She was diagnosed and treated as Takotsubo syndrome.
    Matched MeSH terms: Troponin I
  8. Zainudin H, Caszo BA, Knight VF, Gnanou JV
    Eurasian J Med, 2019 Jun;51(2):116-120.
    PMID: 31258349 DOI: 10.5152/eurasianjmed.2019.18106
    Objective: Regular moderate-intensity exercise has beneficial health effects, whereas regular strenuous exercise increases the production of oxidants that may lead to DNA, skeletal, and cardiac muscle damages. Triathletes experience strenuous muscular activity both during competition and training, being at risk of developing these tissue damages. The objective of the present study was to estimate DNA, skeletal, and cardiac muscle damages using blood biomarkers, 8-hydroxy-2'-deoxyguanosine (8-OHdG), myoglobin, and cardiac troponin I (cTnI) among young triathletes.

    Materials and Methods: Age-matched seven male and seven female triathletes were recruited for the study. They were on a standardized training regimen and on average competed in at least one endurance event every month for the past 3-4 years. Serum biomarkers were measured using enzyme-linked immunosorbent assay at the start and at end of the racing season.

    Results: Both male and female triathletes showed a statistically significant increase in 8-OHdG. A similar pattern of increase was seen with serum myoglobin, which was not statistically significant in both male and female triathletes. cTnI levels did not show any change in both sexes.

    Conclusion: Our study shows that there could be an increased evidence of DNA damage among triathletes. However, similar effects were not observed with skeletal and cardiac muscle biomarkers.

    Matched MeSH terms: Troponin I
  9. Hui H, Gopinath SCB, Ismail ZH, Chen Y, Pandian K, Velusamy P
    Biotechnol Appl Biochem, 2023 Apr;70(2):581-591.
    PMID: 35765758 DOI: 10.1002/bab.2380
    Myocardial infarction (MI) is highly related to cardiac arrest leading to death and organ damage. Radiological techniques and electrocardiography have been used as preliminary tests to diagnose MI; however, these techniques are not sensitive enough for early-stage detection. A blood biomarker-based diagnosis is an immediate solution, and due to the high correlation of troponin with MI, it has been considered to be a gold-standard biomarker. In the present research, the cardiac biomarker troponin I (cTnI) was detected on an interdigitated electrode sensor with various surface interfaces. To detect cTnI, a capture aptamer-conjugated gold nanoparticle probe and detection antibody probe were utilized and compared through an alternating sandwich pattern. The surface metal oxide morphology of the developed sensor was proven by microscopic assessments. The limit of detection with the aptamer-gold-cTnI-antibody sandwich pattern was 100 aM, while it was 1 fM with antibody-gold-cTnI-aptamer, representing 10-fold differences. Further, the high performance of the sensor was confirmed by selective cTnI determination in serum, exhibiting superior nonfouling. These methods of determination provide options for generating novel assays for diagnosing MI.
    Matched MeSH terms: Troponin I
  10. Ahmed R, Tanvir EM, Hossen MS, Afroz R, Ahmmed I, Rumpa NE, et al.
    PMID: 28261310 DOI: 10.1155/2017/5370545
    Propolis contains high concentrations of polyphenols, flavonoids, tannins, ascorbic acid, and reducing sugars and proteins. Malaysian Propolis (MP) has been reported to exhibit high 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical-scavenging activity and ferric reducing antioxidant power (FRAP) values. Herein, we report the antioxidant properties and cardioprotective properties of MP in isoproterenol- (ISO-) induced myocardial infarction in rats. Male Wistar rats (n = 32) were pretreated orally with an ethanol extract of MP (100 mg/kg/day) for 30 consecutive days. Subcutaneous injection of ISO (85 mg/kg in saline) for two consecutive days caused a significant increase in serum cardiac marker enzymes and cardiac troponin I levels and altered serum lipid profiles. In addition significantly increased lipid peroxides and decreased activities of cellular antioxidant defense enzymes were observed in the myocardium. However, pretreatment of ischemic rats with MP ameliorated the biochemical parameters, indicating the protective effect of MP against ISO-induced ischemia in rats. Histopathological findings obtained for the myocardium further confirmed the biochemical findings. It is concluded that MP exhibits cardioprotective activity against ISO-induced oxidative stress through its direct cytotoxic radical-scavenging activities. It is also plausible that MP contributed to endogenous antioxidant enzyme activity via inhibition of lipid peroxidation.
    Matched MeSH terms: Troponin I
  11. Lim WY, Thevarajah TM, Goh BT, Khor SM
    Biosens Bioelectron, 2019 Mar 01;128:176-185.
    PMID: 30685097 DOI: 10.1016/j.bios.2018.12.049
    The early detection of acute myocardial infarction (AMI) upon the onset of chest pain symptoms is crucial for patient survival. However, this detection is challenging, particularly without a persistent elevation of ST-segment reflected in an electrocardiogram or in blood tests. A majority of the available point-of-care testing devices allow accurate and rapid diagnosis of AMI. However, AMI diagnosis is reliable only at intermediate and later stages, with myocardial injury (> 6 h) and MI, based on the expression of specific cardiac biomarkers including troponin I or T (cTnI or cTnT), creatine kinase-MB (CK-MB), and myoglobin. Diagnosis at the early myocardial ischemia stage is not possible. To overcome this limitation, a sensitive and rapid microfluidic paper-based device (µPAD) was developed for the simultaneous detection of multiple cardiac biomarkers for the early and late diagnosis of AMI. The glycogen phosphorylase isoenzyme BB (GPBB) was detected during early (within first 4 h) ischemic myocardial injury. On the same µPAD platform, detection of prolonged elevation of levels of cTnT and CK-MB, which are only produced 6 h after the onset of chest pain in human serum, was possible. Sandwich immunoassay performed on the µPAD achieved reproducibility (RSD approximately 10% and intra-and inter-day precision (CV 10-20%, 99th percentile), as well as consistently stable test results for 28 days, with strong correlation (r2= 0.962), using the standard Siemens Centaur XPT Immunoassay system. The present findings indicate the potential of the µPAD platform as a point-of-care device for the early diagnosis and prognosis of AMI.
    Matched MeSH terms: Troponin I/blood
  12. Carvajal-Zarrabal O, Hayward-Jones PM, Nolasco-Hipolito C, Barradas-Dermitz DM, Calderón-Garcidueñas AL, López-Amador N
    J Forensic Sci, 2017 Sep;62(5):1332-1335.
    PMID: 28111741 DOI: 10.1111/1556-4029.13397
    In the daily practice of forensic pathology, sudden cardiac death (SCD) is a diagnostic challenge. Our aim was to determine the usefulness of blood biomarkers [creatine kinase CK-MB, myoglobin, troponins I and T (cTn-I and T), and lactate dehydrogenase] measured by immunoassay technique, in the postmortem diagnosis of SCD. Two groups were compared, 20 corpses with SCD and 8 controls. Statistical significance was determined by variance analysis procedures, with a post hoc Tukey multiple range test for comparison of means (p < 0.05). SCD cases showed significantly higher levels (p < 0.05) of cTn-T and cTn-I compared to the control group. Although only cases within the first 8 h of postmortem interval were included, and the control group consisted mainly of violent death cases, our results suggest that blood troponin levels may be useful to support a diagnosis of SCD.
    Matched MeSH terms: Troponin I/blood*
  13. Arshad MK, Bin Mohamad Fathil MF, Gopinath SC, Ruslinda AR, Md Nor MN, Lam HY, et al.
    Curr Med Chem, 2016;23(37):4270-4284.
    PMID: 27719655
    Cardiovascular disease (CVD) is a major threat to global health, estimated to be the cause 30 % (17.3 million in 2008) of deaths every year, and the number of deaths caused by CVD is expected to increase further, reaching 23.3 million by 2030. Hence, there is a growing demand for simpler sample extraction, rapid screening results, and intervention of the subsequent analysis in emergency units. In this paper, we reviewed CVD biomarkers in blood- and saliva-based specimens. The history of cardiac biomarkers indicates that in the beginning, cardiac troponin I (cTnI) was a widely accepted 'gold standard' marker due to its high specificity and selectivity. Considering the advantages of salivary-based cardiac biomarkers, we examined correlations between non-invasive (salivary) and invasive (blood) diagnoses, and it was found that C-reactive protein (CRP) provides a better correlation. Despite the low abundance of salivary CRP, several reports displayed the detection limit down to pg/ml using existing technologies. Thus, salivary CRP has the potential to be used for future forefront diagnostics for the early assessment of cardiac risks.
    Matched MeSH terms: Troponin I/blood
  14. Afroz R, Tanvir EM, Karim N, Hossain MS, Alam N, Gan SH, et al.
    Biomed Res Int, 2016;2016:6437641.
    PMID: 27294126 DOI: 10.1155/2016/6437641
    The present study was designed to investigate the cardioprotective effects of Sundarban honey (SH) in rats with isoproterenol- (ISO-) induced myocardial infarction. Adult male Wistar Albino rats were pretreated with Sundarban honey (5 g/kg) daily for a period of 6 weeks. After the treatment period, ISO (85 mg/kg) was subcutaneously injected into the rats at 24 h intervals for 2 days. ISO-induced myocardial damage was indicated by increased serum cardiac specific troponin I levels and cardiac marker enzyme activities including creatine kinase-MB, lactate dehydrogenase, aspartate transaminase, and alanine transaminase. Significant increases in serum total cholesterol, triglycerides, and low-density lipoprotein-cholesterol levels were also observed, along with a reduction in the serum high-density lipoprotein-cholesterol level. In addition to these diagnostic markers, the levels of lipid peroxide products were significantly increased. The activities of antioxidant enzymes such as superoxide dismutase, glutathione peroxidase, and glutathione reductase were significantly decreased in the hearts after ISO-induced myocardial infarction. However, pretreatment of ischemic rats with Sundarban honey brought the biochemical parameters to near normalcy, indicating the protective effect of Sundarban honey against ISO-induced ischemia in rats. Histopathological findings of the heart tissues further confirmed the biochemical findings, indicating that Sundarban honey confers protection against ISO-induced oxidative stress in the myocardium.
    Matched MeSH terms: Troponin I/metabolism
  15. Devereaux PJ, Lamy A, Chan MTV, Allard RV, Lomivorotov VV, Landoni G, et al.
    N Engl J Med, 2022 Mar 03;386(9):827-836.
    PMID: 35235725 DOI: 10.1056/NEJMoa2000803
    BACKGROUND: Consensus recommendations regarding the threshold levels of cardiac troponin elevations for the definition of perioperative myocardial infarction and clinically important periprocedural myocardial injury in patients undergoing cardiac surgery range widely (from >10 times to ≥70 times the upper reference limit for the assay). Limited evidence is available to support these recommendations.

    METHODS: We undertook an international prospective cohort study involving patients 18 years of age or older who underwent cardiac surgery. High-sensitivity cardiac troponin I measurements (upper reference limit, 26 ng per liter) were obtained 3 to 12 hours after surgery and on days 1, 2, and 3 after surgery. We performed Cox analyses using a regression spline that explored the relationship between peak troponin measurements and 30-day mortality, adjusting for scores on the European System for Cardiac Operative Risk Evaluation II (which estimates the risk of death after cardiac surgery on the basis of 18 variables, including age and sex).

    RESULTS: Of 13,862 patients included in the study, 296 (2.1%) died within 30 days after surgery. Among patients who underwent isolated coronary-artery bypass grafting or aortic-valve replacement or repair, the threshold troponin level, measured within 1 day after surgery, that was associated with an adjusted hazard ratio of more than 1.00 for death within 30 days was 5670 ng per liter (95% confidence interval [CI], 1045 to 8260), a level 218 times the upper reference limit. Among patients who underwent other cardiac surgery, the corresponding threshold troponin level was 12,981 ng per liter (95% CI, 2673 to 16,591), a level 499 times the upper reference limit.

    CONCLUSIONS: The levels of high-sensitivity troponin I after cardiac surgery that were associated with an increased risk of death within 30 days were substantially higher than levels currently recommended to define clinically important periprocedural myocardial injury. (Funded by the Canadian Institutes of Health Research and others; VISION Cardiac Surgery ClinicalTrials.gov number, NCT01842568.).

    Matched MeSH terms: Troponin I/blood*
  16. Khalil MI, Tanvir EM, Afroz R, Sulaiman SA, Gan SH
    Biomed Res Int, 2015;2015:286051.
    PMID: 26064893 DOI: 10.1155/2015/286051
    The present study was designed to investigate the cardioprotective effects of Malaysian Tualang honey against isoproterenol- (ISO-) induced myocardial infarction (MI) in rats by investigating changes in the levels of cardiac marker enzymes, cardiac troponin I (cTnI), triglycerides (TG), total cholesterol (TC), lipid peroxidation (LPO) products, and antioxidant defense system combined with histopathological examination. Male albino Wistar rats (n = 40) were pretreated orally with Tualang honey (3 g/kg/day) for 45 days. Subcutaneous injection of ISO (85 mg/kg in saline) for two consecutive days caused a significant increase in serum cardiac marker enzymes (creatine kinase-MB (CK-MB), lactate dehydrogenase (LDH), and aspartate transaminase (AST)), cTnI, serum TC, and TG levels. In addition, ISO-induced myocardial injury was confirmed by a significant increase in heart lipid peroxidation (LPO) products (TBARS) and a significant decrease in antioxidant enzymes (SOD, GPx, GRx, and GST). Pretreatment of ischemic rats with Tualang honey conferred significant protective effects on all of the investigated biochemical parameters. The biochemical findings were further confirmed by histopathological examination in both Tualang-honey-pretreated and ISO-treated hearts. The present study demonstrates that Tualang honey confers cardioprotective effects on ISO-induced oxidative stress by contributing to endogenous antioxidant enzyme activity via inhibition of lipid peroxidation.
    Matched MeSH terms: Troponin I/blood
  17. Lim WY, Goh CH, Thevarajah TM, Goh BT, Khor SM
    Biosens Bioelectron, 2020 Jan 01;147:111792.
    PMID: 31678828 DOI: 10.1016/j.bios.2019.111792
    Recently, surface enhanced Raman scattering (SERS) has attracted much attention in medical diagnosis applications owing to better detection sensitivity and lower limit of detection (LOD) than colorimetric detection. In this paper, a novel calibration-free SERS-based μPAD with multi-reaction zones for simultaneous quantitative detection of multiple cardiac biomarkers - GPBB, CK-MB and cTnT for early diagnosis and prognosis of acute myocardial infarction (AMI) are presented. Three distinct Raman probes were synthesised, subsequently conjugated with respective detecting antibodies and used as SERS nanotags for cardiac biomarker detection. Using a conventional calibration curve, quantitative simultaneous measurement of multiple cardiac biomarkers on SERS-based μPAD was performed based on the characteristic Raman spectral features of each reporter used in different nanotags. However, a calibration free point-of-care testing device is required for fast screening to rule-in and rule-out AMI patients. Partial least squares predictive models were developed and incorporated into the immunosensing system, to accurately quantify the three unknown cardiac biomarkers levels in serum based on the previously obtained Raman spectral data. This method allows absolute quantitative measurement when conventional calibration curve fails to provide accurate estimation of cardiac biomarkers, especially at low and high concentration ranges. Under an optimised condition, the LOD of our SERS-based μPAD was identified at 8, 10, and 1 pg mL-1, for GPBB, CK-MB and cTnT, respectively, which is well below the clinical cutoff values. Therefore, this proof-of-concept technique shows significant potential for highly sensitive quantitative detection of multiplex cardiac biomarkers in human serum to expedite medical decisions for enhanced patient care.