METHODS: Overall, 29 prospectively recruited patients had FLT PET, FDG PET and CT-scans performed prior to and post one chemotherapy cycle; 10 had prior talc pleurodesis. Patients were followed for overall survival. CT response was assessed using mRECIST. Radiomic features were extracted using the MiM software platform. Changes in maximum SUV (SUVmax), mean SUV (SUVmean), FDG total lesion glycolysis (TLG), FLT total lesion proliferation (TLP) and metabolic tumour volume (MTV) after one chemotherapy cycle.
RESULTS: Cox univariate analysis demonstrated FDG PET radiomics were confounded by talc pleurodesis, and that percentage change in FLT MTV was predictive of overall survival. Cox multivariate analysis showed a 10% increase in FLT tumour volume corresponded with 9.5% worsened odds for overall survival (P = 0.028, HR = 1.095, 95% CI [1.010, 1.187]). No other variables were significant on multivariate analysis.
CONCLUSION: This is the first prospective study showing the statistical significance of FLT PET tumour volumes for measuring mesothelioma treatment response. FLT may be better than FDG for monitoring mesothelioma treatment response, which could help optimise mesothelioma treatment regimes.
MATERIALS AND METHODS: The courses of the mandibular canal in 202 cone-beam computed tomography scanned images of healthy Malaysians were evaluated, and trifid mandibular canal (TMC) when present, were recorded and studied in detail by categorizing them to a new classification (comprising of 12 types). The diameter and length of canals were also measured, and their shape determined.
RESULTS: Trifid mandibular canals were observed in 12 (5.9%) subjects or 16 (4.0%) hemi-mandibles. There were 10 obvious categories out the 12 types of TMCs listed. All TMCs (except one) were observed in patients older than 30 years. The prevalence according to ethnicity was 6 in Malays, 5 in Chinese and 1 in Indian. Four (33.3%) patients had bilateral TMCs, which was not seen in the Indian subject. More than half (56.3%) of the accessory canals were located above the main mandibular canal. Their mean diameter was 1.32 mm and 1.26 mm for the first and second accessory canal, and the corresponding lengths were 20.42 mm and 21.60 mm, respectively. Most (62.5%) canals had irregularly shaped lumen; there were more irregularly shaped canals in the second accessory canal than the first branch. None of the second accessory canal was oval (in shape).
CONCLUSIONS: This new classification can be applied for the variations in the branching pattern, length and shape of TMCs for better clinical description.
METHODS: CBCT images were scanned retrospectively and the ones including bilateral M1Ms were included in the study. The evaluation was performed by 1 researcher in each country, trained with CBCT technology. A written and video instruction program explaining the protocol to be followed step-by-step was provided to all observers to calibrate them. The CBCT imaging screening procedure consisted of evaluating axial sections from coronal to apical. The presence of DLC and RE in M1Ms (yes/no) was identified and recorded.
RESULTS: Six thousand three hundred four CBCTs, representing 12,608 M1Ms, were evaluated. A significant difference was found between countries regarding the prevalence of both RE and DLC (P .05).
CONCLUSION: The overall prevalence of RE and DLC in M1Ms was 3% and 22%. Additionally, both RE and DLC showed substantial bilaterally. These variations should be considered by endodontic clinicians during endodontic procedures in order to avoid potential complications.
METHODS: We conducted a comprehensive literature review, searching databases such as PubMed, Embase, and Web of Science until June 2023. Our objective was to identify studies that compared the efficacy of 68Ga-PSMA-11 PET/CT and mpMRI in detecting primary prostate cancer. To determine heterogeneity, the I2 statistic was used. Meta-regression analysis and leave-one-out sensitivity analysis were conducted to identify potential sources of heterogeneity.
RESULTS: Initially, 1286 publications were found, but after careful evaluation, only 16 studies involving 1227 patients were analyzed thoroughly. The results showed that the 68Ga-PSMA-11 PET/CT method had a pooled sensitivity and specificity of 0.87 (95 % CI: 0.80-0.92) and 0.80 (95 % CI: 0.69-0.89), respectively, for diagnosing prostatic cancer. Similarly, the values for mpMRI were determined as 0.84 (95 % CI: 0.75-0.92) and 0.74 (95 % CI: 0.61-0.86), respectively. There were no significant differences in diagnostic effectiveness observed when comparing two primary prostate cancer methodologies (pooled sensitivity P = 0.62, pooled specificity P = 0.50). Despite this, the funnel plots showed symmetry and the Egger test results (P values > 0.05) suggested there was no publication bias.
CONCLUSIONS: After an extensive meta-analysis, it was found that both 68Ga-PSMA-11 PET/CT and mpMRI demonstrate similar diagnostic effectiveness in detecting primary prostate cancer. Future larger prospective studies are warranted to investigate this issue further.
METHODS: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15).
RESULTS: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%.
CONCLUSIONS: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value.
METHODS: A ball phantom was scanned using panoramic mode of the Planmeca ProMax 3D Mid CBCT unit (Planmeca, Helsinki, Finland) with standard exposure settings used in clinical practice (60 kV, 2 mA, and maximum FOV). An automated calculator algorithm was developed in MATLAB platform. Two parameters associated with panoramic image distortion such as balls diameter and distance between middle and tenth balls were measured. These automated measurements were compared with manual measurement using the Planmeca Romexis and ImageJ software.
RESULTS: The findings showed smaller deviation in distance difference measurements by proposed automated calculator (ranged 3.83 mm) as compared to manual measurements (ranged 5.00 for Romexis and 5.12 mm for ImageJ software). There was a significant difference (p
METHODS: CBCT was used to assess 200 joints in 100 subjects (mean age, 30.5 years). i-CAT CBCT software and The Mimics 16.0 software were employed to measure the volume, metrical size, position of each condyle sample and the thickness of the roof of the glenoid fossa (RGF).
RESULTS: No significant gender differences were noted in thickness of the RGF and condylar length; however condylar volume, width, height and the joint spaces were significantly greater among males. With regards to comparison of both TMJs, the means of condylar volume, width and length of the right TMJ were significantly higher, while the means of the left condylar height and thickness of RGF were higher. When comparing the condylar measurements and the thickness of RGF between the two ethnic groups, we found no significant difference for all measurements with exception of condylar height, which is higher among Chinese.
CONCLUSION: The similarity in measurements for Malays and Chinese may be due to their common origin. This information can be clinically useful in establishing the diagnostic criteria for condylar volume, metrical size, and position in the Malaysian East Asians population.