Displaying all 4 publications

Abstract:
Sort:
  1. Faizal A, Bujang Safawi E, Sundram M, Kueh NS, Normala B
    Urol Int, 2011;87(1):117-9.
    PMID: 21709396 DOI: 10.1159/000324543
    Surgical wound infection after a renal transplant procedure can lead to graft loss in the presence of host immunosuppression and graft exposure to the environment. Early cover of the wound with well-vascularized tissue will facilitate early wound healing and preservation of the graft. The pedicle anterolateral thigh perforator flap is a popular flap used for soft tissue reconstruction in the groin and perineum. We present a case of an anterolateral thigh flap used to cover an exposed transplanted kidney after surgical wound breakdown.
    Matched MeSH terms: Surgical Wound Dehiscence/etiology
  2. Ramzisham AR, Raflis AR, Khairulasri MG, Ooi Su Min J, Fikri AM, Zamrin MD
    Asian Cardiovasc Thorac Ann, 2009 Dec;17(6):587-91.
    PMID: 20026533 DOI: 10.1177/0218492309348948
    Sternal dehiscence is a rare but devastating complication following median sternotomy for cardiac surgery. The optimal technique for sternal closure is unclear. We conducted this prospective randomized trial to compare the incidence of sternal dehiscence after figure-of-8 and simple interrupted suturing in patients undergoing coronary artery bypass grafting. Between January 2007 and June 2008, 98 patients had figure-of-8 suturing and 97 had interrupted sutures. The mean age of the patients was 60.9 +/- 7.6 years. The overall sternal dehiscence rate was 8%; 7 cases in the in figure-of-8 group and 9 in the interrupted group. Thirteen patients had no wound infection and healed with conservative treatment. Only 3 patients had sternal dehiscence with infection: 2 with simple interrupted closure and 1 with figure-of-8 sternal closure. There was no significant difference in rates of sternal dehiscence between the 2 groups. It was concluded that figure-of-8 sternal suturing is equally effective as simple interrupted suturing in preventing sternal dehiscence.
    Matched MeSH terms: Surgical Wound Dehiscence/etiology
  3. Jaafar N, Nor GM
    Singapore Dent J, 2000 Feb;23(1):24-8.
    PMID: 11602946
    The aim of this retrospective study is to report on the prevalence of post-extraction complications among patients attending the Oral Surgery outpatient clinic of the Faculty of Dentistry, University of Malaya over a 12-month period from January to December, 1992. The prevalence of post-extraction complications which required further treatment was only 3.4% (n = 100), out of a total of 2968 patients who had extraction of one or more permanent teeth. Analysis based on complete clinical reports (n = 79) showed that dry socket accounted for nine out of ten cases of post-extraction complications. However the aetiology was largely unknown. No obvious association with medical history could be made. Lower teeth were more likely to have complications. The most common teeth associated with dry socket were the molars (76%) and premolars (19%). The most common molars to be affected are the first, followed by the third and lastly the second molars. A brief review of current aetiological factors of dry socket was discussed.
    Matched MeSH terms: Surgical Wound Dehiscence/etiology
  4. Vaiyapuri GR, Han HC, Lee LC, Tseng LA, Wong HF
    Int Urogynecol J, 2011 Jul;22(7):869-77.
    PMID: 21479713 DOI: 10.1007/s00192-011-1400-9
    INTRODUCTION AND HYPOTHESIS: This retrospective study reports the 1-year outcome in women who underwent mesh-augmented Prolift surgery performed from 2006 to 2008. There were a total of 254 patients, with 128, 106 and 20 patients receiving total, anterior and posterior Prolift, respectively.

    METHODS: Incidence of thigh pain was lower in 2008 compared to 2006 and 2007 (p < 0.0001). The percentage of patients requiring blood transfusions (p = 0.09), duration of IDC ≥ 7 days (p = 0.27), wound dehiscence and re-operation rate were lower in 2008 in contrast to 2006 and 2007 (p = 0.43). Only 209 patients (82.3%) were available for review at 1 year. There were two (1.0%) cases of recurrent vault prolapse.

    RESULTS: The subjective and objective cure rates at 1 year after this mesh implant surgery in 2006, 2007 and 2008 were 92.1% and 92.1%; 97.0% and 92.4% and 100% and 97%, respectively. The mesh erosion rate was remarkably lower in 2008 as compared to 2007 and 2006 (p < 0.001).

    CONCLUSIONS: This synthetic mesh-augmented implant surgery is effective and safe, and surgical outcome appears related to the learning curve of the surgeon.

    Matched MeSH terms: Surgical Wound Dehiscence/etiology
Filters
Contact Us

Please provide feedback to Administrator ([email protected])