Displaying publications 1 - 20 of 105 in total

Abstract:
Sort:
  1. Korrani ZS, Khalili E, Kamyab H, Wan Ibrahim WA, Hashim H
    Environ Res, 2023 Dec 01;238(Pt 2):117167.
    PMID: 37722580 DOI: 10.1016/j.envres.2023.117167
    In this work, a simple sol-gel approach was used for the preparation of cyanopropyl (CNPr) functionalized silica nanoparticles (SiO2-CNPr) that tetraethoxysilane (TEOS) and cyanopropyltriethoxysilane (CNPrTEOS) used as precursors. This as-prepared SiO2-CNPr nanoparticle sorbent was first characterized using FESEM, EDX, FTIR, TGA, and BET techniques. Then, the SiO2-CNPr nanoparticle was applied as a new SPE sorbent for determining trace levels of OPPs in environmental water samples. To enhance the simultaneous extraction of non-polar or/and polar OPPs and to obtain the most efficient sorbent, several sol-gel synthesis parameters were studied. In addition, the effect of several effective parameters on SPE performance was investigated toward simultaneous extraction of non-polar or/and polar OPPs. Moreover, the figures of merit such as precision, linearity, LOQ, LOD, and recovery were evaluated for the sorbent. Finally, the designed SiO2-CNPr SPE was used to determine OPPs in real water samples, and its extraction performance was compared to commercial cartridges based on cyanopropyl.
    Matched MeSH terms: Solid Phase Extraction/methods
  2. Zango ZU, Ethiraj B, Al-Mubaddel FS, Alam MM, Lawal MA, Kadir HA, et al.
    Environ Res, 2023 Aug 15;231(Pt 2):116102.
    PMID: 37196688 DOI: 10.1016/j.envres.2023.116102
    Perfluoroalkyl carboxylic acids (PFCAs) are sub-class of perfluoroalkyl substances commonly detected in water matrices. They are persistent in the environment, hence highly toxic to living organisms. Their occurrence at trace amount, complex nature and prone to matrix interference make their extraction and detection a challenge. This study consolidates current advancements in solid-phase extraction (SPE) techniques for the trace-level analysis of PFCAs from water matrices. The advantages of the methods in terms of ease of applications, low-cost, robustness, low solvents consumption, high pre-concentration factors, better extraction efficiency, good selectivity and recovery of the analytes have been emphasized. The article also demonstrated effectiveness of some porous materials for the adsorptive removal of the PFCAs from the water matrices. Mechanisms of the SPE/adsorption techniques have been discussed. The success and limitations of the processes have been elucidated.
    Matched MeSH terms: Solid Phase Extraction/methods
  3. Lim TS, Ch'ng ACW, Song BPC, Lai JY
    Methods Mol Biol, 2023;2702:275-290.
    PMID: 37679625 DOI: 10.1007/978-1-0716-3381-6_14
    Phage display is a technique that allows the presentation of unique proteins on the surface of bacteriophages. The phage particles are usually screened via repetitive rounds of antigen-guided selection and phage amplification. The main advantage of this approach lies in the physical linkage between phenotype and genotype. This feature allows the isolation of single unique clones from a panning campaign consisting of a highly diverse population of clones. Due to the high-throughput nature of this technique, different approaches have been developed to assist phage display selections. One of which involves utilizing a streptavidin-coated solid-phase extraction (SPE) tip that is mounted to an electronically controlled motorized multichannel pipette. In this chapter, we will entail the procedures involved in the adaptation of a commercial SPE tip (MSIA™ streptavidin D.A.R.T's®) as the solid phase. This protocol is an updated version of a previous protocol with some minor refinements.
    Matched MeSH terms: Solid Phase Extraction
  4. Wan Ibrahim WA, Nodeh HR, Aboul-Enein HY, Sanagi MM
    Crit Rev Anal Chem, 2015;45(3):270-87.
    PMID: 25849825 DOI: 10.1080/10408347.2014.938148
    Recently, a simple, rapid, high-efficiency, selective, and sensitive method for isolation, preconcentration, and enrichment of analytes has been developed. This new method of sample handling is based on ferum oxides as magnetic nanoparticles (MNPs) and has been used for magnetic solid-phase extraction (MSPE) of various analytes from various matrices. This review focuses on the applications of modified ferum oxides, especially modified Fe3O4 MNPs, as MSPE adsorbent for pesticide isolation from various matrices. Further perspectives on MSPE based on modified Fe3O4 for inorganic metal ions, organic compounds, and biological species from water samples are also presented. Ferum(III) oxide MNPs (Fe2O3) are also highlighted.
    Matched MeSH terms: Solid Phase Extraction/methods*
  5. Hakami AAH, Wabaidur SM, Ali Khan M, Abdullah Alothman Z, Rafatullah M, Siddiqui MR
    Molecules, 2020 Oct 06;25(19).
    PMID: 33036289 DOI: 10.3390/molecules25194564
    Lower dye concentrations and the presence of several dyes along with other matrices in environmental samples restrict their determination. Herein, a highly sensitive and rapid ultra-performance tandem mass spectrometric method was developed for simultaneous determination of cationic dyes, namely methylene blue (MB), rhodamine B (RB) and crystal violet (CV), in environmental samples. To preconcentrate environmental samples, solid-phase extraction cartridges were developed by using hydrogen peroxide modified pistachio shell biomass (MPSB). The surface morphological and chemical functionalities of MPSB were well characterized. The developed method was validated considering different validation parameters. In terms of accuracy and precision, the %RSD for all three dyes at all four concentration points was found to be between 1.26 and 2.76, while the accuracy reported in terms of the recovery was found to be 98.02%-101.70%. The recovery was found to be in the range of 98.11% to 99.55%. The real sample analysis shows that MB, RB, and CV were found in the ranges of 0.39-5.56, 0.32-1.92 and 0.27-4.36 μg/mL, respectively.
    Matched MeSH terms: Solid Phase Extraction/methods*
  6. Badawy MEI, El-Nouby MAM, Kimani PK, Lim LW, Rabea EI
    Anal Sci, 2022 Dec;38(12):1457-1487.
    PMID: 36198988 DOI: 10.1007/s44211-022-00190-8
    Analytical processes involving sample preparation, separation, and quantifying analytes in complex mixtures are indispensable in modern-day analysis. Each step is crucial to enriching correct and informative results. Therefore, sample preparation is the critical factor that determines both the accuracy and the time consumption of a sample analysis process. Recently, several promising sample preparation approaches have been made available with environmentally friendly technologies with high performance. As a result of its many advantages, solid-phase extraction (SPE) is practiced in many different fields in addition to the traditional methods. The SPE is an alternative method to liquid-liquid extraction (LLE), which eliminates several disadvantages, including many organic solvents, a lengthy operation time and numerous steps, potential sources of error, and high costs. SPE advanced sorbent technology reorients with various functions depending on the structure of extraction sorbents, including reversed-phase, normal-phase, cation exchange, anion exchange, and mixed-mode. In addition, the commercial SPE systems are disposable. Still, with the continual developments, the restricted access materials (RAM) and molecular imprinted polymers (MIP) are fabricated to be active reusable extraction cartridges. This review will discuss all the theoretical and practical principles of the SPE techniques, focusing on packing materials, different forms, and performing factors in recent and future advances. The information about novel methodological and instrumental solutions in relation to different variants of SPE techniques, solid-phase microextraction (SPME), in-tube solid-phase microextraction (IT-SPME), and magnetic solid-phase extraction (MSPE) is presented. The integration of SPE with analytical chromatographic techniques such as LC and GC is also indicated. Furthermore, the applications of these techniques are discussed in detail along with their advantages in analyzing pharmaceuticals, biological samples, natural compounds, pesticides, and environmental pollutants, as well as foods and beverages.
    Matched MeSH terms: Solid Phase Extraction*
  7. Lau EV, Gan S, Ng HK
    Int J Anal Chem, 2010;2010:398381.
    PMID: 20396670 DOI: 10.1155/2010/398381
    This paper aims to provide a review of the analytical extraction techniques for polycyclic aromatic hydrocarbons (PAHs) in soils. The extraction technologies described here include Soxhlet extraction, ultrasonic and mechanical agitation, accelerated solvent extraction, supercritical and subcritical fluid extraction, microwave-assisted extraction, solid phase extraction and microextraction, thermal desorption and flash pyrolysis, as well as fluidised-bed extraction. The influencing factors in the extraction of PAHs from soil such as temperature, type of solvent, soil moisture, and other soil characteristics are also discussed. The paper concludes with a review of the models used to describe the kinetics of PAH desorption from soils during solvent extraction.
    Matched MeSH terms: Solid Phase Extraction
  8. Lok, C.M., Son, R.
    MyJurnal
    Since the introduction of the molecularly imprinting technology (MIT) in 1970s, it becomes an emerging technology with the potential for wide-ranging applications in food manufacturing, processing, analysis and quality control. It has been successfully applied in food microbiology, removal of undesirable components
    from food matrices, detection of hazardous residues or pollutants and sensors. Molecularly imprinted solid-phase extraction (MISPE) is the most common application so far. The review describes the methods of making the molecularly imprinted polymer systems, the application of the technology in food safety issues and the remaining challenges.
    Matched MeSH terms: Solid Phase Extraction
  9. Lee MJ, Ramanathan S, Mansor SM, Yeong KY, Tan SC
    Anal Biochem, 2018 02 15;543:146-161.
    PMID: 29248503 DOI: 10.1016/j.ab.2017.12.021
    A method using solid phase extraction and liquid chromatography-tandem mass spectrometry to quantitatively detect mitragynine, 16-carboxy mitragynine, and 9-O-demethyl mitragynine in human urine samples was developed and validated. The relevant metabolites were identified using multiple reaction monitoring in positive ionization mode using nalorphine as an internal standard. The method was validated for accuracy, precision, recovery, linearity, and lower limit of quantitation. The intra- and inter-day accuracy and precision were found in the range of 83.6-117.5% with coefficient of variation less than 13%. The percentage of recovery for mitragynine, 16-carboxy mitragynine, and 9-O-demethyl mitragynine was within the range of 80.1-118.9%. The lower limit of quantification was 1 ng/mL for mitragynine, 2 ng/mL for 16-carboxy mitragynine, and 50 ng/mL for 9-O-demethyl mitragynine. The developed method was reproducible, high precision and accuracy with good linearity and recovery for mitragynine, 16-carboxy mitragynine, and 9-O-demethyl mitragynine in human urine.
    Matched MeSH terms: Solid Phase Extraction
  10. Omar MM, Wan Ibrahim WA, Elbashir AA
    Food Chem, 2014 Sep 1;158:302-9.
    PMID: 24731346 DOI: 10.1016/j.foodchem.2014.02.045
    A sol-gel hybrid sorbent, methyltrimethoxysilane-tetraethoxysilane (MTMOS-TEOS) was successfully used as new dispersive solid phase extraction (dSPE) sorbent material in the determination of acrylamide in several Sudanese foods and analysis using GC-MS. Several important dSPE parameters were optimised. Under the optimised conditions, excellent linearity (r(2)>0.9998) was achieved using matrix matched standard calibration in the concentration range 50-1000 μg kg(-1). The limits of detection (LOD) and limit of quantification ranged from 9.1 to 12.8 μg/kg and 27.8-38.9 μg/kg, respectively. The precision (RSD%) of the method was ⩽6.6% and recoveries of acrylamide obtained were in the range of 88-103%, (n=3). The LOD obtained is comparable with the LODs of primary secondary amine dSPE. The proposed MTMOS-TEOS dSPE method is direct and safe for acrylamide analysis, showed reliable method validation performances and good cleanup effects. It was successfully applied to the analysis of acrylamide in real food samples.
    Matched MeSH terms: Solid Phase Extraction/instrumentation; Solid Phase Extraction/methods*
  11. Iqbal MS, Bahari MB, Darwis Y, Iqbal MZ, Hayat A, Venkatesh G
    J AOAC Int, 2013 6 19;96(2):290-4.
    PMID: 23767352
    A simple and selective RP-HPLC-UV method with SPE was developed and validated for the quantification of cefotaxime in all-in-one total parenteral nutrition (AIO-TPN) admixtures. Chromatographic separation was achieved on a 5 pm particle size C18 DB column (250 x 4.6 mm id) using the mobile phase ammonium acetate (25 mM, pH 4.0)-50% acetonitrile in methanol (80 + 20, v/v). The flow rate was 0.9 mL/min and the detection wavelength was 254 nm. The analyte was extracted from AIO-TPN admixtures by means of an SPE method. The cefotaxime calibration curve was linear over a concentration range of 100-1400 microg/mL with a correlation coefficient of > or = 0.9994. The intraday accuracy and precision for cefotaxime were < or = -3.15 and < or = 3.08%, respectively, whereas the interday accuracy and precision were < or = -2.48 and < or = 2.25%, respectively. The method was successfully applied to stability studies of cefotaxime in the presence of micronutrients together with low and high concentrations of macronutrients in AIO-TPN admixtures. Cefotaxime was degraded by 13.00 and 26.05% at room temperature (25 +/- 2 degrees C) after 72 h in low and high macronutrient concentration formulations of AIO-TPN admixtures, respectively. The values of cefotaxime degradation rates for low and high macronutrient concentration formulations of AIO-TPN admixtures were -0.164 and -0.353, respectively. These results indicated that there was a higher rate of degradation in the AIO-TPN admixture formulations containing high concentrations of macronutrients.
    Matched MeSH terms: Solid Phase Extraction/methods*; Solid Phase Extraction/standards*
  12. Wan Ibrahim WA, Abd Ali LI, Sulaiman A, Sanagi MM, Aboul-Enein HY
    Crit Rev Anal Chem, 2014;44(3):233-54.
    PMID: 25391563 DOI: 10.1080/10408347.2013.855607
    The progress of novel sorbents and their function in preconcentration techniques for determination of trace elements is a topic of great importance. This review discusses numerous analytical approaches including the preparation and practice of unique modification of solid-phase materials. The performance and main features of ion-imprinting polymers, carbon nanotubes, biosorbents, and nanoparticles are described, covering the period 2007-2012. The perspective and future developments in the use of these materials are illustrated.
    Matched MeSH terms: Solid Phase Extraction/instrumentation; Solid Phase Extraction/methods*
  13. Lal A, Tan G, Chai M
    Anal Sci, 2008 Feb;24(2):231-6.
    PMID: 18270414
    A new extraction and cleanup procedure with gas chromatography was developed for the sensitive determination of acephate, dimethoate, malathion, diazinon, quinalphos, chlorpyrifos, profenofos, alpha-endosulfan, beta-endosulfan, chlorothalonil and carbaryl using 1-chloro-4-fluorobenzene as an internal standard in fruits and vegetables. Several extracting and eluting solvents for solid-phase extraction were investigated. The overall extracting solvent with a mixture of acetone:ethyl acetate:hexane (10:80:10, v/v/v) and a eluting solvent of 5% acetone in hexane used with the RPC18 cartridge gave the best recovery for all of the investigated pesticides, and minimized the interference from co-extractants. Under the optimal extraction and clean-up conditions, recoveries of 85 - 99% with RSD < 5.0% (n = 3) for most of the pesticides at the 0.02 - 0.5 mg/kg level were obtained. The limit of detection was between 0.005 - 0.01 mg/kg and the limit of quantification was 0.01 mg/kg. This analytical procedure was characterized with high accuracy and acceptable sensitivity to meet requirements for monitoring pesticides in crops.
    Matched MeSH terms: Solid Phase Extraction/instrumentation; Solid Phase Extraction/methods*
  14. Al-Qaim FF, Mussa ZH, Yuzir A
    Anal Bioanal Chem, 2018 Aug;410(20):4829-4846.
    PMID: 29806068 DOI: 10.1007/s00216-018-1120-9
    The scarcity of data about the occurrence of pharmaceuticals in water bodies in Malaysia prompted us to develop a suitable analytical method to address this issue. We therefore developed a method based on solid-phase extraction combined with liquid chromatography-time of flight/mass spectrometry (SPE-LC-TOF/MS) for the analysis of sixteen prescribed and two nonprescribed pharmaceuticals that are potentially present in water samples. The levels of these pharmaceuticals, which were among the top 50 pharmaceuticals consumed in Malaysia during the period 2011-2014, in influent and effluent of five sewage treatment plants (STPs) in Bangi, Malaysia, were then analyzed using the developed method. All of the pharmaceuticals were separated chromatographically using a 5 μm, 2.1 mm × 250 mm C18 column at a flow rate of 0.3 mL/min. Limits of quantification (LOQs) were 0.3-8.2 ng/L, 6.5-89 ng/L, and 11.1-93.8 ng/L in deionized water (DIW), STP effluent, and STP influent, respectively, for most of the pharmaceuticals. Recoveries were 51-108%, 52-118%, and 80-107% from the STP influent, STP effluent, and DIW, respectively, for most of the pharmaceuticals. The matrix effect was also evaluated. The signals from carbamazepine, diclofenac sodium, and mefenamic acid were found to be completely suppressed in the STP influent. The signals from other compounds were found to be influenced by matrix effects more strongly in STP influent (enhancement or suppression of signal ≤180%) than in effluent (≤94%). The signal from prednisolone was greatly enhanced in the STP influent, indicating a matrix effect of -134%. Twelve pharmaceuticals were frequently detected in all five STPs, and caffeine, prazosin, and theophylline presented the highest concentrations among all the pharmaceuticals monitored: up to 7611, 550, and 319 ng/L in the STP influent, respectively. To the best of our knowledge, this is the first time that prazosin has been detected in a water matrix in Malaysia. Graphical abstract ᅟ.
    Matched MeSH terms: Solid Phase Extraction/instrumentation; Solid Phase Extraction/methods*
  15. Samer Al-Battawi, Yu Bin Ho, Mohd Talib Latif, Vivien How, Karuppiah Thilakavathy
    MyJurnal
    Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous pollutants with toxic effects and adverse health impacts on general population. Several methods of extraction had been applied to extract PAHs from human blood samples such as solid phase extraction (SPE). The SPE represents one of the most common techniques for extraction and clean-up procedures as it needs low quantity of solvents with less manual efforts. Similarly, various analytical instruments like gas chromatography coupled to mass spectrometry (GC-MS) was used to measure the PAHs levels. Gas chromatog- raphy is a simple, fast, and very efficient method for solvents and small organic molecules. This review provides an overview of the measured concentrations of PAHs in human blood samples through the application of SPE and GC- MS during the last ten years. While these studies used various solvents, their application of SPE method and GC-MS revealed rewarding results about the determination of PAHs levels in the human samples.
    Matched MeSH terms: Solid Phase Extraction
  16. Ong SQ, Ab Majid AH, Ahmad H
    Trop Life Sci Res, 2017 Jul;28(2):45-55.
    PMID: 28890760 MyJurnal DOI: 10.21315/tlsr2017.28.2.4
    In this study, bifenthrin (Maxxthor SC, Ensystex Australasia Pty Ltd), imidacloprid (Prothor SC, Ensystex Australasia Pty Ltd) and fipronil (Regent(®)50SC, Bayer) were applied on the natural infest manures according to the manufacturer rate during a broiler breeding cycle. Solvent direct-immersion extraction (SDIE) was used in detecting the target compound and later, quantification of the insecticide residues in field condition was investigated. The samples were prior cleaned up by solid-phase extraction (SPE) and analysed by Ultra-Performance Liquid Chromatography (UPLC) - photodiode array (PDA) system. In the field trial, three insecticides were showed accumulation during the broiler breeding period and it is suggested that they acted as adulticides when applied on the poultry manures, this is supported by the significant correlation between the increment of insecticide residues to the reduction percentage of adult flies (<0.05). Fipronil showed significantly greater reduction on the adult fly compared to the other insecticides, in which the reduction rate compared to control population at the end of the broiler breeding period; fipronil, imidaclopril and bifenthrin reduced 51.51%, 28.30% and 30.84% of adult flies, respectively.
    Matched MeSH terms: Solid Phase Extraction
  17. Selby-Pham SNB, Siow LF, Bennett LE
    Food Funct, 2020 Jan 29;11(1):907-920.
    PMID: 31942898 DOI: 10.1039/c9fo01149h
    After oil extraction, palm fruit biomass contains abundant water-soluble phytochemicals (PCs) with proven bioactivity in regulating oxidative stress and inflammation (OSI). For optimal bioefficacy following oral consumption, the pharmacokinetic plasma peak (Tmax) should be bio-matched with the onset of OSI, which can be predicted from the Phytochemical Absorption Prediction (PCAP) model and methodology. Predicted absorption and potential for regulation of OSI by measures of total phenolic content, antioxidant capacity and hydrogen peroxide production capacity, were applied to characterise eight extracts from mesocarp fibre and kernel shells of oil-depleted palm fruits. Results indicated post-consumption absorption Tmax ranges of 0.5-12 h and 2-6 h for intake in liquid and solid forms, respectively, and generally high antioxidant activity of the extracts. The research supports that PC extracts of palm fruit biomass have broad potential uses for human health as dietary antioxidants in foods, supplements or functional beverages.
    Matched MeSH terms: Solid Phase Extraction
  18. Rashidi Nodeh H, Wan Ibrahim WA, Kamboh MA, Sanagi MM
    Food Chem, 2018 Jan 15;239:208-216.
    PMID: 28873561 DOI: 10.1016/j.foodchem.2017.06.094
    Graphene (G) modified with magnetite (Fe3O4) and sol-gel hybrid tetraethoxysilane-methyltrimethoxysilane (TEOS-MTMOS) was used as a clean-up adsorbent in magnetic solid phase extraction (MSPE) for direct determination of acrylamide in various food samples prior to gas chromatography-mass spectrometry analysis. Good linearity (R2=0.9990) was achieved for all samples using matrix-matched calibration. The limit of detection (LOD=3×SD/m) obtained was 0.061-2.89µgkg-1 for the studied food samples. Native acrylamide was found to be highest in fried potato with bright-fleshed (900.81µgkg-1) and lowest in toasted bread (5.02µgkg-1). High acrylamide relative recovery (RR=82.7-105.2%) of acrylamide was obtained for spiked (5 and 50µgkg-1) food samples. The Fe3O4@G-TEOS-MTMOS is reusable up to 7 times as a clean-up adsorbent with good recovery (>85%). The presence of native acrylamide was confirmed by mass analysis at m/z=71 ([C3H5NO]+) and m/z=55 ([C3H3O]+).
    Matched MeSH terms: Solid Phase Extraction
  19. Muhammad Yunus F, Alias Y, Yahya N, Mohamad Zain NN, Raoov M
    PMID: 38466777 DOI: 10.1080/19440049.2024.2326426
    Poly(methyl methacrylate-vinyl imidazole bromide) (poly-MMA-IL)-grafted magnetic nanoparticles were successfully developed and applied in the micro-magnetic solid phase extraction (μ-MSPE) for 16 types of polycyclic aromatic hydrocarbons (PAHs) from tea, fried food, and grilled food samples via gas chromatography flame ionization detector (GC-FID). One variable at a time (OVAT) and response surface methodology (RSM) were used for efficient optimization. The validation method showed a good coefficient of determination (R2) ranging from 0.9901 to 0.9982 (n = 3) with linearity of 0.2 μg L-1-500 μg L-1. Detection and quantification limits were 0.06 µg L-1-0.32 µg L-1 and 0.18 µg L-1-0.97 µg L-1. Additionally, satisfactory reproducibility was attained with intra-day and inter-day precisions having RSD ranges of 3.6%-11.1%. The spiked recovery value of 16 PAHs in fried food, grilled food and tea samples obtained from the night market in Malaysia ranged from 80%-12%, respectively.
    Matched MeSH terms: Solid Phase Extraction
  20. Raoov M, Mohamad S, bin Abas MR, Surikumaran H
    Talanta, 2014 Dec;130:155-63.
    PMID: 25159393 DOI: 10.1016/j.talanta.2014.06.067
    Cyclodextrin-ionic liquid polymer (βCD-BIMOTs-TDI) is a new class of macroporous material and has great potential to be used as an SPE adsorbent material for extraction of phenols in river water samples. Six phenols, as model analytes, were extracted on a βCD-BIMOTs-TDI SPE cartridge, and then, eluted with 2 mL of methanol containing 1% acetic acid. The optimum experimental condition was 15 mL of sample volume (sample at pH 6) and 2 mL of methanol containing 1% acetic acid as an eluent solvent. The eluent concentration was determined by using Gas Chromatography-Flame Ionization Detector (GC-FID). Under optimized condition, high sensitivity (detection limits 0.23-0.35 µg/L) and good recoveries (87-116%) were achieved with satisfactory relative standard deviation (RSD) (0.1-1.7%). The developed βCD-BIMOTs-TDI-SPE was then compared with other adsorbents, and the obtained results showed that the βCD-BIMOTs-TDI exhibited higher extraction recovery due to the unique structure and properties. Finally, the βCD-BIMOTs-TDI was applied as a solid phase extraction sorbent for phenols determination under optimized condition, in river and tap waters, prior to the GC-FID separation.
    Matched MeSH terms: Solid Phase Extraction/methods*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links