Displaying publications 1 - 20 of 2043 in total

Abstract:
Sort:
  1. Abrams MB, Bjaalie JG, Das S, Egan GF, Ghosh SS, Goscinski WJ, et al.
    Neuroinformatics, 2022 Jan;20(1):25-36.
    PMID: 33506383 DOI: 10.1007/s12021-020-09509-0
    There is great need for coordination around standards and best practices in neuroscience to support efforts to make neuroscience a data-centric discipline. Major brain initiatives launched around the world are poised to generate huge stores of neuroscience data. At the same time, neuroscience, like many domains in biomedicine, is confronting the issues of transparency, rigor, and reproducibility. Widely used, validated standards and best practices are key to addressing the challenges in both big and small data science, as they are essential for integrating diverse data and for developing a robust, effective, and sustainable infrastructure to support open and reproducible neuroscience. However, developing community standards and gaining their adoption is difficult. The current landscape is characterized both by a lack of robust, validated standards and a plethora of overlapping, underdeveloped, untested and underutilized standards and best practices. The International Neuroinformatics Coordinating Facility (INCF), an independent organization dedicated to promoting data sharing through the coordination of infrastructure and standards, has recently implemented a formal procedure for evaluating and endorsing community standards and best practices in support of the FAIR principles. By formally serving as a standards organization dedicated to open and FAIR neuroscience, INCF helps evaluate, promulgate, and coordinate standards and best practices across neuroscience. Here, we provide an overview of the process and discuss how neuroscience can benefit from having a dedicated standards body.
    Matched MeSH terms: Reproducibility of Results
  2. Leong SS, Wong JHD, Rozalli FI, Yahya F, Tee YC, Yamin LSM, et al.
    Skeletal Radiol, 2024 Mar;53(3):455-463.
    PMID: 37594519 DOI: 10.1007/s00256-023-04425-1
    OBJECTIVE: To establish the scanning protocol for 2-dimensional shear wave elastography (SWE) on normal entheses by investigating the possible confounding factors that may increase the variability of measured elasticity.

    MATERIAL AND METHODS: 30 normal quadriceps entheses were scanned using SWE to compare the stiffness and coefficient variation by changing the ultrasonic coupling gel thickness, knee position, region of interest size, and scanning plane.

    RESULTS: No significant difference in median shear wave velocity (SWV) was observed in different coupling gel thicknesses. The median SWV was higher in the knee flexion position than in the extended position (p  0.05). For interobserver reliability for the proposed protocol, the intraclass correlation coefficients was 0.763.

    CONCLUSION: In this study, we determined supine position with the knee extended; using 2.0 mm diameter region of interest and image acquisition at the longitudinal plane with thicker layer coupling gel seems most appropriate to reliably image healthy quadriceps entheses with SWE.

    Matched MeSH terms: Reproducibility of Results
  3. Sharif Nia H, She L, Somasundram S, Khoshnavay Fomani F, Kaveh O, Hosseini L
    Int J Aging Hum Dev, 2023 Mar;96(2):248-262.
    PMID: 35266410 DOI: 10.1177/00914150221084650
    Objective:The present study was designed to assess the construct validity and reliability of the Persian version of the 12-item Expectations Regarding Aging (ERA) survey among the older adult Iranian population. Methods: The Persian version of this scale was developed using translation and revision in the current study. The construct validity was assessed through exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). The reliability was assessed through internal consistency (Cronbach's alpha and McDonald's omega), composite reliability (CR), and maximal reliability (MaXR). The data compiled online was based on a sample of 400 older adults aged 65 years and older. Results: The Persian version includes 12 items loading onto three factors with 12 items explaining 46.633% of the total variance with excellent internal consistency and reliability. Conclusion: The Persian version of ERA is reliable and valid that can be used to assess the ERA concept among older adults.
    Matched MeSH terms: Reproducibility of Results*
  4. Zaki R, Bulgiba A, Nordin N, Azina Ismail N
    Iran J Basic Med Sci, 2013 Jun;16(6):803-7.
    PMID: 23997908
    Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.
    Matched MeSH terms: Reproducibility of Results
  5. Gayatri RW, Katmawanti S, Wardani HE, Low WY
    Enferm Clin, 2021 04;31 Suppl 2:S311-S315.
    PMID: 33849188 DOI: 10.1016/j.enfcli.2020.09.019
    The purpose of this study is to develop an interactive service for people with DM and design a product specifically for the Android operating system. This study employs a research and development (R&D) design. The research phase consisted of a situation analysis, data collection, product design, expert validation, product revision, product tryout, and final revision. The research instrument was a questionnaire. Data analysis involved descriptive quantitative in percentage form. The results of the validation from the Android application experts, which focused on display quality, technical concerns, audio, and video quality, were found at 93.75% (very acceptable). In addition, the results of the validity assessment from the material experts, including general health experts and nutritionists, reached 98.08% (very acceptable) and 86.54% (very feasible), respectively. Based on the results of expert validation, the application design is categorized as very acceptable for development as a DM interactive service product.
    Matched MeSH terms: Reproducibility of Results
  6. Rupa C, Midhunchakkaravarthy D, Hasan MK, Alhumyani H, Saeed RA
    Math Biosci Eng, 2021 08 23;18(5):7010-7027.
    PMID: 34517569 DOI: 10.3934/mbe.2021349
    The use of advanced technologies has increased drastically to maintain any sensitive records related to education, health, or finance. It helps to protect the data from unauthorized access by attackers. However, all the existing advanced technologies face some issues because of their uncertainties. These technologies have some lapses to provide privacy, attack-free, transparency, reliability, and flexibility. These characteristics are essential while managing any sensitive data like educational certificates or medical certificates. Hence, we designed an Industry 5.0 based blockchain application to manage medical certificates using Remix Ethereum blockchain in this paper. This application also employs a distributed application (DApp) that uses a test RPC-based Ethereum blockchain and user expert system as a knowledge agent. The main strength of this work is the maintenance of existing certificates over a blockchain with the creation of new certificates that use logistic Map encryption cipher on existing medical certificates while uploading into the blockchain. This application helps to quickly analyze the birth, death, and sick rate as per certain features like location and year.
    Matched MeSH terms: Reproducibility of Results
  7. Mahdavi M, Mahdavi M
    Sains Malaysiana, 2014;43:629-636.
    This paper considers a Monte Carlo simulation based method for estimating cycle stocks (production lot-sizing stocks) in a typical batch production system, where a variety of products is scheduled for production at determined periods of time. Delivery time is defined as the maximum lead time and pre-assembly processing time of the product's raw materials in the method. The product's final assembly cycle and delivery time, which were obtained via the production schedule and supply chain simulation, respectively, were both considered to estimate the demand distribution of product based on total duration. Efficient random variates generators were applied to model the lead time of the supply chain's stages. In order to support the performance reliability of the proposed method, a real case study is conducted and numerically analyzed.
    Matched MeSH terms: Reproducibility of Results
  8. Arends S, Drenthen J, Van den Bergh PYK, Hadden RDM, Shahrizaila N, Dimachkie MM, et al.
    J Peripher Nerv Syst, 2022 Sep;27(3):197-205.
    PMID: 35700346 DOI: 10.1111/jns.12504
    Electrodiagnostic (EDx) studies are helpful in diagnosing and subtyping of Guillain-Barré syndrome (GBS). Published criteria for differentiation into GBS subtypes focus on cutoff values, but other items receive less attention, although they may influence EDx subtyping: (a) extensiveness of EDx testing, (b) nerve-specific considerations, (c) distal compound muscle action potential (CMAP)-amplitude requirements, (d) criteria for conduction block and temporal dispersion. The aims of this study were to investigate how these aspects were approached by neuromuscular EDx experts in practice and how this was done in previously published EDx criteria for GBS. A completed questionnaire was returned by 24 (of 49) members of the electrophysiology expertise group from the International GBS Outcome Study. Six published EDx criteria for GBS subtyping were compared regarding these aspects. The indicated minimal number of motor nerves to study varied among respondents and tended to be more extensive in equivocal than normal studies. Respondents varied considerably regarding usage of compression sites for subtyping (median/wrist, ulnar/elbow, peroneal/fibular head): 29% used all variables from all sites, 13% excluded all sites, and 58% used only some sites and/or variables. Thirty-eight percent of respondents required a minimal distal CMAP amplitude to classify distal motor latency as demyelinating, and 58% did for motor conduction velocity. For proximal/distal CMAP-amplitude ratio and F-wave latency, a requisite minimal CMAP amplitude was more often required (79%). Also, the various published criteria sets showed differences on all items. Practical use of EDx criteria for subtyping GBS vary extensively across respondents, potentially lowering the reproducibility of GBS subtyping.
    Matched MeSH terms: Reproducibility of Results
  9. Zulkipli NS, Satari SZ, Hariri F, Abdullah NA, Wan Yusoff WNS, Hussin AG
    Cleft Palate Craniofac J, 2023 Nov;60(11):1484-1493.
    PMID: 35711157 DOI: 10.1177/10556656221107524
    INTRODUCTION: Apert, Crouzon, and Pfeiffer syndromes are common genetic syndromes related to syndromic craniosynostosis (SC), whereby it is a congenital defect that occurs when the cranial growth is distorted. Identifying cranial angles associated with these 3 syndromes may assist the surgical team to focus on a specific cranial part during the intervention planning, thus optimizing surgical outcomes and reducing potential morbidity.

    OBJECTIVE: The aim of this study is to identify the cranial angles, which are associated with Apert, Crouzon, and Pfeiffer syndromes.

    METHODS: The cranial computed tomography scan images of 17 patients with SC and 22 control groups aged 0 to 12 years who were treated in the University Malaya Medical Centre were obtained, while 12 angular measurements were attained using the Mimics software. The angular data were then divided into 2 groups (patients aged 0 to 24 months and >24 months). This work proposes a 95% confidence interval (CI) for angular mean to detect the abnormality in patient's cranial growth for the SC syndromes.

    RESULTS: The 95% CI of angular mean for the control group was calculated and used as an indicator to confirm the abnormality in patient's cranial growth that is associated with the 3 syndromes. The results showed that there are different cranial angles associated with these 3 syndromes.

    CONCLUSIONS: All cranial angles of the patients with these syndromes lie outside the 95% CI of angular mean of control group, indicating the reliability of the proposed CI in the identification of abnormality in the patient's cranial growth.

    Matched MeSH terms: Reproducibility of Results
  10. Zailani NNB, Ho PC
    Eur J Drug Metab Pharmacokinet, 2023 Sep;48(5):467-494.
    PMID: 37495930 DOI: 10.1007/s13318-023-00846-4
    This review provides an overview on the current applications of dried blood spots (DBS) as matrices for therapeutic drug (TDM) and drug or disease response monitoring (DRM). Compared with conventional methods using plasma/serum, DBS offers several advantages, including minimally invasiveness, a small blood volume requirement, reduced biohazardous risk, and improved sample stability. Numerous assays utilising DBS for TDM have been reported in the literature over the past decade, covering a wide range of therapeutic drugs. Several factors can affect the accuracy and reliability of the DBS sampling method, including haematocrit (HCT), blood volume, sampling paper and chromatographic effects. It is crucial to evaluate the correlation between DBS concentrations and conventional plasma/serum concentrations, as the latter has traditionally been used for clinical decision. The feasibility of using DBS sampling method as an option for home-based TDM is also discussed. Furthermore, DBS has also been used as a matrix for monitoring the drug or disease responses (DRM) through various approaches such as genotyping, viral load measurement, assessment of inflammatory factors, and more recently, metabolic profiling. Although this research is still in the development stage, advancements in technology are expected to lead to the identification of surrogate biomarkers for drug treatment in DBS and a better understanding of the correlation between DBS drug levels and drug responses. This will make DBS a valuable matrix for TDM and DRM, facilitating the achievement of pharmacokinetic and pharmacodynamic correlations and enabling personalised therapy.
    Matched MeSH terms: Reproducibility of Results
  11. Amalina F, Krishnan S, Zularisam AW, Nasrullah M
    Sci Total Environ, 2024 Mar 01;914:169608.
    PMID: 38157898 DOI: 10.1016/j.scitotenv.2023.169608
    Employing biomass for environmental conservation is regarded as a successful and environmentally friendly technique since they are cost-effective, renewable, and abundant. Biochar (BC), a thermochemically converted biomass, has a considerably lower production cost than the other conventional activated carbons. This material's distinctive properties, including a high carbon content, good electrical conductivity (EC), high stability, and a large surface area, can be utilized in various research fields. BC is feasible as a renewable source for potential applications that may achieve a comprehensive economic niche. Despite being an inexpensive and environmentally sustainable product, research has indicated that pristine BC possesses restricted properties that prevent it from fulfilling the intended remediation objectives. Consequently, modifications must be made to BC to strengthen its physicochemical properties and, thereby, its efficacy in decontaminating the environment. Modified BC, an enhanced iteration of BC, has garnered considerable interest within academia. Many modification techniques have been suggested to augment BC's functionality, including its adsorption and immobilization reliability. Modified BC is overviewed in its production, functionality, applications, and regeneration. This work provides a holistic review of the recent advances in synthesizing modified BC through physical, chemical, or biological methods to achieve enhanced performance in a specific application, which has generated considerable research interest. Surface chemistry modifications require the initiation of surface functional groups, which can be accomplished through various techniques. Therefore, the fundamental objective of these modification techniques is to improve the efficacy of BC contaminant removal, typically through adjustments in its physical or chemical characteristics, including surface area or functionality. In addition, this article summarized and discussed the applications and related mechanisms of modified BC in environmental decontamination, focusing on applying it as an ideal adsorbent, soil amendment, catalyst, electrochemical device, and anaerobic digestion (AD) promoter. Current research trends, future directions, and academic demands were available in this study.
    Matched MeSH terms: Reproducibility of Results
  12. Jayaraj VJ, Ng CW, Hoe VC, Chong DW, Rampal S
    BMJ Health Care Inform, 2024 Jan 18;31(1).
    PMID: 38238022 DOI: 10.1136/bmjhci-2023-100759
    OBJECTIVE: Data-driven innovations are essential in strengthening disease control. We developed a low-cost, open-source system for robust epidemiological intelligence in response to the COVID-19 crisis, prioritising scalability, reproducibility and dynamic reporting.

    METHODS: A five-tiered workflow of data acquisition; processing; databasing, sharing, version control; visualisation; and monitoring was used. COVID-19 data were initially collated from press releases and then transitioned to official sources.

    RESULTS: Key COVID-19 indicators were tabulated and visualised, deployed using open-source hosting in October 2022. The system demonstrated high performance, handling extensive data volumes, with a 92.5% user conversion rate, evidencing its value and adaptability.

    CONCLUSION: This cost-effective, scalable solution aids health specialists and authorities in tracking disease burden, particularly in low-resource settings. Such innovations are critical in health crises like COVID-19 and adaptable to diverse health scenarios.

    Matched MeSH terms: Reproducibility of Results
  13. Quek KF, Low WY, Razack AH, Chua CB, Loh CS
    Med J Malaysia, 2002 Jun;57(2):169-77.
    PMID: 24326647
    The aim of the study was to validate the Malay version of the General Quentionnaire (GHQ-12) in patients with psychiatric morbidity secondary to urological disorder. Validity and reliability were studied in patients with lower urinary tract symptoms (LUTS) and patients without LUTS. Internal consistency was excellent. A high degree of internal consistency was observed for each of the 12 items and total scores (Cronbach's alpha value = 0.50 and higher and 0.65 respectively. Test-retest correlation coefficient for the 12 items scores was highly significant. Intraclass correlation coefficient was high (ICC=0.47 and above). A significant level between baseline and post-treatment scores were observed across 3 items in the surgical group. The Mal-GHQ-12 is a suitable, reliable, valid and sensitive to clinical change in the Malaysian population.
    Matched MeSH terms: Reproducibility of Results*
  14. Shamsuddin N, Poh BK, Syed Zakaria SZ, Noor MI, Jamal R
    Int J Public Health Res, 2015;5(2):643-653.
    MyJurnal
    Introduction: Validation of instruments is essential when assessing physical activity (PA). The aim of this study was to validate a Malay language version of the International Physical Activity Questionnaire (IPAQ-M) against Actical accelerometer and to determine its reliability and validity.
    Methods: A total of 90 Malay adults aged 35-65 years old participating in The Malaysian Cohort project were recruited for this study. The IPAQ-M is comprised of 12 items, covering vigorous, moderate, walking, sitting and sleeping activities, and was administered on two occasions (Day 1 and Day 9) by interviewing the participants. Participants wore the Actical accelerometer for seven consecutive days between the two interview sessions. Results Validity tests showed that time spent in moderate-vigorous physical activity (MVPA) (min/wk) from IPAQ-M was significantly correlated with MVPA from accelerometer (rho=0.32, p<0.01). Time spent in vigorous activity (rho=0.44) and total activity (rho=0.36) from IPAQ-M were significantly correlated (p<0.01) with that measured by accelerometer, but no correlation was observed for sedentary behaviour. Reliability tests revealed significant correlations between the two interview sessions for all intensities of PA (rho=0.55 to 0.71, p<0.01). Bland-Altman plots showed that time spent in MVPA for IPAQ-M was significantly different from that measured by accelerometer (mean difference: 98.02 min/wk; 95% limits of agreement: -785.33 to 1317.83 min/wk; p<0.01). When classifying people into meeting PA recommendation, the agreement between the two instruments was fair (κ=0.22).
    Conclusions The IPAQ-M has acceptable validity for MVPA, vigorous and total physical activity, and was reliable for assessing the physical activity of Malay adults.
    Keywords Health care workers - Knowledge - Practice - Universal precaution - Health center.
    Study name: The Malaysian Cohort (TMC) Project
    Matched MeSH terms: Reproducibility of Results*
  15. Siraji MA, Lazar RR, van Duijnhoven J, Schlangen LJM, Haque S, Kalavally V, et al.
    Sci Rep, 2023 Dec 13;13(1):22151.
    PMID: 38092767 DOI: 10.1038/s41598-023-48241-y
    Light exposure is an essential driver of health and well-being, and individual behaviours during rest and activity modulate physiologically relevant aspects of light exposure. Further understanding the behaviours that influence individual photic exposure patterns may provide insight into the volitional contributions to the physiological effects of light and guide behavioural points of intervention. Here, we present a novel, self-reported and psychometrically validated inventory to capture light exposure-related behaviour, the Light Exposure Behaviour Assessment (LEBA). An expert panel prepared the initial 48-item pool spanning different light exposure-related behaviours. Responses, consisting of rating the frequency of engaging in the per-item behaviour on a five-point Likert-type scale, were collected in an online survey yielding responses from a geographically unconstrained sample (690 completed responses, 74 countries, 28 time zones). The exploratory factor analysis (EFA) on an initial subsample (n = 428) rendered a five-factor solution with 25 items (wearing blue light filters, spending time outdoors, using a phone and smartwatch in bed, using light before bedtime, using light in the morning and during daytime). In a confirmatory factor analysis (CFA) performed on an independent subset of participants (n = 262), we removed two additional items to attain the best fit for the five-factor solution (CFI = 0.95, TLI = 0.95, RMSEA = 0.06). The internal consistency reliability coefficient for the total instrument yielded McDonald's Omega = 0.68. Measurement model invariance analysis between native and non-native English speakers showed our model attained the highest level of invariance (residual invariance CFI = 0.95, TLI = 0.95, RMSEA = 0.05). Lastly, a short form of the LEBA (n = 18 items) was developed using Item Response Theory on the complete sample (n = 690). The psychometric properties of the LEBA indicate the usability for measuring light exposure-related behaviours. The instrument may offer a scalable solution to characterise behaviours that influence individual photic exposure patterns in remote samples. The LEBA inventory is available under the open-access CC-BY license. Instrument webpage: https://leba-instrument.org/ GitHub repository containing this manuscript: https://github.com/leba-instrument/leba-manuscript .
    Matched MeSH terms: Reproducibility of Results*
  16. Faruque MR, Islam MT
    PLoS One, 2014;9(10):e109947.
    PMID: 25350398 DOI: 10.1371/journal.pone.0109947
    In this study, a double-negative triangular metamaterial (TMM) structure, which exhibits a resounding electric response at microwave frequency, was developed by etching two concentric triangular rings of conducting materials. A finite-difference time-domain method in conjunction with the lossy-Drude model was used in this study. Simulations were performed using the CST Microwave Studio. The specific absorption rate (SAR) reduction technique is discussed, and the effects of the position of attachment, the distance, and the size of the metamaterials on the SAR reduction are explored. The performance of the double-negative TMMs in cellular phones was also measured in the cheek and the tilted positions using the COMOSAR system. The TMMs achieved a 52.28% reduction for the 10 g SAR. These results provide a guideline to determine the triangular design of metamaterials with the maximum SAR reducing effect for a mobile phone.
    Matched MeSH terms: Reproducibility of Results
  17. Zubair S, Fisal N
    Sensors (Basel), 2014;14(5):8996-9026.
    PMID: 24854362 DOI: 10.3390/s140508996
    The need for implementing reliable data transfer in resource-constrained cognitive radio ad hoc networks is still an open issue in the research community. Although geographical forwarding schemes are characterized by their low overhead and efficiency in reliable data transfer in traditional wireless sensor network, this potential is still yet to be utilized for viable routing options in resource-constrained cognitive radio ad hoc networks in the presence of lossy links. In this paper, a novel geographical forwarding technique that does not restrict the choice of the next hop to the nodes in the selected route is presented. This is achieved by the creation of virtual clusters based on spectrum correlation from which the next hop choice is made based on link quality. The design maximizes the use of idle listening and receiver contention prioritization for energy efficiency, the avoidance of routing hot spots and stability. The validation result, which closely follows the simulation result, shows that the developed scheme can make more advancement to the sink as against the usual decisions of relevant ad hoc on-demand distance vector route select operations, while ensuring channel quality. Further simulation results have shown the enhanced reliability, lower latency and energy efficiency of the presented scheme.
    Matched MeSH terms: Reproducibility of Results
  18. Tan CL, Hassali MA, Saleem F, Shafie AA, Aljadhey H, Gan VB
    Pharm Pract (Granada), 2015 Apr-Jun;13(3):598.
    PMID: 26445622 DOI: 10.18549/PharmPract.2015.03.598
    (i) To develop the Pharmacy Value-Added Services Questionnaire (PVASQ) using emerging themes generated from interviews. (ii) To establish reliability and validity of questionnaire instrument.
    Matched MeSH terms: Reproducibility of Results
  19. Lotfivand N, Abdolzadeh V, Hamidon MN
    ISA Trans, 2016 Jul;63:425-435.
    PMID: 27038885 DOI: 10.1016/j.isatra.2016.03.012
    Numerous applications of artificial olfaction resulting from research in many branches of sciences have caused considerable interest in the enhancement of these systems. In this paper, we offer an architecture which is suitable for critical applications, such as medical diagnosis, where reliability and precision are deemed important. The proposed architecture is able to tolerate failures in the sensors of the array. In this study, the discriminating ability of the proposed architecture in detecting complex odors, as well as the performance of the proposed architecture in encountering sensor failure, were investigated and compared with the generic architecture. The results demonstrated that by applying the proposed architecture in the artificial olfactory system, the performance of system in the healthy mode was identical to the classic structure. However, in the faulty situation, the proposed architecture implied high identification ability of odor samples, while the generic architecture showed very poor performance in the same situation. Based on the results, it was possible to achieve high odor identification through the developed artificial olfactory system using the proposed architecture.
    Matched MeSH terms: Reproducibility of Results
  20. Zulkifli Yusop, Harisaweni, Fadhilah Yusof
    Sains Malaysiana, 2016;45:87-97.
    Rainfall intensity is the main input variable in various hydrological analysis and modeling. Unfortunately, the quality of rainfall data is often poor and reliable data records are available at coarse intervals such as yearly, monthly and daily. Short interval rainfall records are scarce because of high cost and low reliability of the measurement and the monitoring systems. One way to solve this problem is by disaggregating the coarse intervals to generate the short one using the stochastic method. This paper describes the use of the Bartlett Lewis Rectangular Pulse (BLRP) model. The method was used to disaggregate 10 years of daily data for generating hourly data from 5 rainfall stations in Kelantan as representative area affected by monsoon period and 5 rainfall stations in Damansara affected by inter-monsoon period. The models were evaluated on their ability to reproduce standard and extreme rainfall model statistics derived from the historical record over disaggregation simulation results. The disaggregation of daily to hourly rainfall produced monthly and daily means and variances that closely match the historical records. However, for the disaggregation of daily to hourly rainfall, the standard deviation values are lower than the historical ones. Despite the marked differences in the standard deviation, both data series exhibit similar patterns and the model adequately preserve the trends of all the properties used in evaluating its performances.
    Matched MeSH terms: Reproducibility of Results
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links