  1. Talib I, Sundaraj K, Hussain J, Lam CK, Ahmad Z
    Sci Rep, 2022 Sep 27;12(1):16086.
    PMID: 36168025 DOI: 10.1038/s41598-022-20223-6
    This study aimed to analyze anthropometrics and mechanomyography (MMG) signals as forearm flexion, pronation, and supination torque predictors. 25 young, healthy, male participants performed isometric forearm flexion, pronation, and supination tasks from 20 to 100% maximal voluntary isometric contraction (MVIC) while maintaining 90° at the elbow joint. Nine anthropometric measures were recorded, and MMG signals from the biceps brachii (BB), brachialis (BRA), and brachioradialis (BRD) muscles were digitally acquired using triaxial accelerometers. These were then correlated with torque values. Significant positive correlations were found for arm circumference (CA) and MMG root mean square (RMS) values with flexion torque. Flexion torque might be predicted using CA (r = 0.426-0.575), a pseudo for muscle size while MMGRMS (r = 0.441), an indication of muscle activation.
    Matched MeSH terms: Pronation/physiology
  2. Talib I, Sundaraj K, Lam CK
    Sci Rep, 2019 11 07;9(1):16166.
    PMID: 31700129 DOI: 10.1038/s41598-019-52536-4
    This study aimed to quantify the association of four anthropometric parameters of the human arm, namely, the arm circumference (CA), arm length (LA), skinfold thickness (ST) and inter-sensor distance (ISD), with amplitude (RMS) and crosstalk (CT) of mechanomyography (MMG) signals. Twenty-five young, healthy, male participants were recruited to perform forearm flexion, pronation and supination torque tasks. Three accelerometers were employed to record the MMG signals from the biceps brachii (BB), brachialis (BRA) and brachioradialis (BRD) at 80% maximal voluntary contraction (MVC). Signal RMS was used to quantify the amplitude of the MMG signals from a muscle, and cross-correlation coefficients were used to quantify the magnitude of the CT among muscle pairs (BB & BRA, BRA & BRD, and BB & BRD). For all investigated muscles and pairs, RMS and CT showed negligible to low negative correlations with CA, LA and ISD (r = -0.0001--0.4611), and negligible to moderate positive correlations with ST (r = 0.004-0.511). However, almost all of these correlations were statistically insignificant (p > 0.05). These findings suggest that RMS and CT values for the elbow flexor muscles recorded and quantified using accelerometers appear invariant to anthropometric parameters.
    Matched MeSH terms: Pronation/physiology*
  3. Talib I, Sundaraj K, Lam CK
    J Musculoskelet Neuronal Interact, 2020 06 01;20(2):194-205.
    PMID: 32481235
    OBJECTIVE: To analyse the influence of muscle fibre axis on the degree of crosstalk in mechanomyographic (MMG) signals during sustained isometric forearm flexion, pronation and supination exercises performed at 80% maximum voluntary contraction (MVC) at an elbow joint angle of 90°.

    METHODS: MMG signals in longitudinal, lateral and transverse directions of muscle fibres were recorded from the elbow flexors of twenty-five male subjects using triaxial accelerometers. Cross-correlation coefficients were used to quantify the degree of crosstalk in all nine possible pairs of fibre axes, all muscle pairs and all exercises.

    RESULTS: MMG root mean square (RMS) was statistically significant among the fibre axes (p<0.05, η2=0.17- 0.34) except for biceps brachii and brachioradialis in supination and brachialis in flexion. Overall mean crosstalk values in the three muscle pairs (biceps brachii & brachialis, brachialis & brachioradialis and brachioradialis & biceps brachii) were found to be 6.09-52.17%, 4.01-61.42% and 2.16-51.85%, respectively. Crosstalk values showed statistical significance among all nine axes pairs (p<0.05, η2=0.16-0.51) except for biceps brachii & brachialis during pronation. The transverse axes pair generated the lowest mean crosstalk values (2.16-9.14%).

    CONCLUSION: MMG signals recorded using accelerometers from the transverse axes of muscle fibres in the elbow flexors are unique and yield the least amount of crosstalk.

    Matched MeSH terms: Pronation/physiology*