Displaying all 2 publications

Abstract:
Sort:
  1. Samsiah A, Othman N, Jamshed S, Hassali MA, Wan-Mohaina WM
    Eur J Clin Pharmacol, 2016 Dec;72(12):1515-1524.
    PMID: 27637912
    PURPOSE: Reporting and analysing the data on medication errors (MEs) is important and contributes to a better understanding of the error-prone environment. This study aims to examine the characteristics of errors submitted to the National Medication Error Reporting System (MERS) in Malaysia.

    METHODS: A retrospective review of reports received from 1 January 2009 to 31 December 2012 was undertaken. Descriptive statistics method was applied.

    RESULTS: A total of 17,357 MEs reported were reviewed. The majority of errors were from public-funded hospitals. Near misses were classified in 86.3 % of the errors. The majority of errors (98.1 %) had no harmful effects on the patients. Prescribing contributed to more than three-quarters of the overall errors (76.1 %). Pharmacists detected and reported the majority of errors (92.1 %). Cases of erroneous dosage or strength of medicine (30.75 %) were the leading type of error, whilst cardiovascular (25.4 %) was the most common category of drug found.

    CONCLUSIONS: MERS provides rich information on the characteristics of reported MEs. Low contribution to reporting from healthcare facilities other than government hospitals and non-pharmacists requires further investigation. Thus, a feasible approach to promote MERS among healthcare providers in both public and private sectors needs to be formulated and strengthened. Preventive measures to minimise MEs should be directed to improve prescribing competency among the fallible prescribers identified.

    Matched MeSH terms: Product Surveillance, Postmarketing/statistics & numerical data*
  2. Colombo A, Chandrasekhar J, Aquino M, Ong TK, Sartori S, Baber U, et al.
    Int J Cardiol, 2019 05 15;283:67-72.
    PMID: 30826192 DOI: 10.1016/j.ijcard.2019.01.053
    BACKGROUND: The COMBO stent (OrbusNeich Medical, Ft. Lauderdale, Florida) is a new-generation bio-engineered drug eluting stent, combining an abluminal coating of a bioabsorbable polymer matrix for sustained release of sirolimus and luminal anti-CD34 coating for endothelial progenitor cell capture and rapid endothelialization.

    METHODS: The Multinational Abluminal Sirolimus Coated BiO-Engineered StenT (MASCOT) registry was a prospective post-marketing study conducted from June 2014-May 2017 across 60 centers globally. Patients were eligible if COMBO stent implantation was attempted, and they received dual antiplatelet therapy (DAPT) per local guidelines. Follow-up was conducted by trained research staff at 1, 6 and 12 months by phone or clinic visit to capture clinical events and DAPT cessation events. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, non-fatal myocardial infarction not clearly attributable to a non-target vessel, or ischemia-driven target lesion revascularization.

    RESULTS: A total of 2614 patients were enrolled over the study period with 96.7% completion of 1-year follow-up. The mean age of enrolled patients was 62.9 ± 11.2 years and 23.0% were female. Diabetes mellitus was present at baseline in 33.5%. A total of 56.1% patients underwent PCI for acute coronary syndrome (ACS). The 1-year primary endpoint of TLF occurred in 3.4% patients (n = 88). Definite stent thrombosis occurred in 0.5% patients (n = 12).

    CONCLUSION: The MASCOT post marketing registry provides comprehensive safety and efficacy outcomes following contemporary PCI using the novel COMBO stent in an all-comer population. This platform is associated with low rates of 1-year TLF and ST. CLINICALTRIALS.

    GOV IDENTIFIER: NCT02183454.

    Matched MeSH terms: Product Surveillance, Postmarketing/statistics & numerical data*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links