METHODS: A retrospective review of reports received from 1 January 2009 to 31 December 2012 was undertaken. Descriptive statistics method was applied.
RESULTS: A total of 17,357 MEs reported were reviewed. The majority of errors were from public-funded hospitals. Near misses were classified in 86.3 % of the errors. The majority of errors (98.1 %) had no harmful effects on the patients. Prescribing contributed to more than three-quarters of the overall errors (76.1 %). Pharmacists detected and reported the majority of errors (92.1 %). Cases of erroneous dosage or strength of medicine (30.75 %) were the leading type of error, whilst cardiovascular (25.4 %) was the most common category of drug found.
CONCLUSIONS: MERS provides rich information on the characteristics of reported MEs. Low contribution to reporting from healthcare facilities other than government hospitals and non-pharmacists requires further investigation. Thus, a feasible approach to promote MERS among healthcare providers in both public and private sectors needs to be formulated and strengthened. Preventive measures to minimise MEs should be directed to improve prescribing competency among the fallible prescribers identified.
METHODS: The Multinational Abluminal Sirolimus Coated BiO-Engineered StenT (MASCOT) registry was a prospective post-marketing study conducted from June 2014-May 2017 across 60 centers globally. Patients were eligible if COMBO stent implantation was attempted, and they received dual antiplatelet therapy (DAPT) per local guidelines. Follow-up was conducted by trained research staff at 1, 6 and 12 months by phone or clinic visit to capture clinical events and DAPT cessation events. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, non-fatal myocardial infarction not clearly attributable to a non-target vessel, or ischemia-driven target lesion revascularization.
RESULTS: A total of 2614 patients were enrolled over the study period with 96.7% completion of 1-year follow-up. The mean age of enrolled patients was 62.9 ± 11.2 years and 23.0% were female. Diabetes mellitus was present at baseline in 33.5%. A total of 56.1% patients underwent PCI for acute coronary syndrome (ACS). The 1-year primary endpoint of TLF occurred in 3.4% patients (n = 88). Definite stent thrombosis occurred in 0.5% patients (n = 12).
CONCLUSION: The MASCOT post marketing registry provides comprehensive safety and efficacy outcomes following contemporary PCI using the novel COMBO stent in an all-comer population. This platform is associated with low rates of 1-year TLF and ST. CLINICALTRIALS.
GOV IDENTIFIER: NCT02183454.
MATERIALS AND METHODS: In this open label, single-arm, observational, post marketing study, patients received biphasic isophane insulin injection as per the Prescribing Information; and were assessed for safety (adverse events including hypoglycaemia), effectiveness (glycosylated haemoglobin [HbA1c]; fasting blood sugar, [FBS]; and patient's condition by patient and physician) over a period of 24 weeks.
RESULTS: Adult male and female diabetes patients (N=119; type 2 DM, n=117) with a mean (SD) diabetes duration of 13 years were included. No new safety signals have been identified. Significant reduction in HbA1c was observed at weeks 12 and 24 (mean [SD] - baseline: 9.6% [1.9]; Week 12: 9.0% [1.7] and at Week 24: 9.1% [1.7]; p < 0.001). There were 10 serious and 9 non-serious adverse events reported in the study. Expected mild events included hypoglycaemia and injection site pruritus. However, the majority of the adverse events were non-study drug related events. No deaths were reported during the study.
DISCUSSION: Biphasic isophane insulin injection was well tolerated with no new safety concerns. It was found effective in post- marketing studies conducted in routine clinical settings when administered in DM patients in this study.