Displaying all 11 publications

Abstract:
Sort:
  1. Yeap TB, Teah MK, Ramly AKM, Bong CP
    BMJ Case Rep, 2021 Apr 09;14(4).
    PMID: 33837036 DOI: 10.1136/bcr-2021-242118
    Anaesthesia for patients with huge mediastinal mass is very challenging due to the cardiorespiratory embarrassment that may occur. We present a patient with this condition, which was complicated by total airway obstruction, intraoperatively. We discuss the importance of patient positioning and the role of spontaneous ventilation.
    Matched MeSH terms: Patient Positioning
  2. Yeap TB, Shabani NS, Bong CP, Tan HS
    BMJ Case Rep, 2021 Jul 13;14(7).
    PMID: 34257132 DOI: 10.1136/bcr-2021-244358
    Intraoperative impending compartment syndrome (ICS) is an extremely rare but lethal occurrence that can involve the upper and/or lower limb(s). It commonly occurs in patients who undergo anaesthesia in various special positions such as lithotomy, lateral decubitus or prone. We present a patient who developed an ICS of his left forearm during a cervical spine surgery in prone position. This devastating condition was fortunately identified when the pulse oximetry, intra-arterial wave form and motor-evoked potentials signal disappeared abruptly from our monitors. We discuss our perioperative challenges and management for the patient which had eventually saved the patient's limb.
    Matched MeSH terms: Patient Positioning
  3. Lee Wan Fei S, Abdullah KL
    J Clin Nurs, 2015 Mar;24(5-6):672-82.
    PMID: 25319831 DOI: 10.1111/jocn.12712
    To determine the most effective position jaundiced neonates should assume during phototherapy from appraised randomised controlled trials.
    Matched MeSH terms: Patient Positioning*
  4. Leong WS, Liong ML, Liong YV, Wu DB, Lee SW
    Urology, 2014 Jan;83(1):40-4.
    PMID: 24044912 DOI: 10.1016/j.urology.2013.08.004
    To determine the efficacy of a combination of simultaneous shock wave lithotripsy (SWL), hydration with controlled inversion therapy compared with SWL with hydration alone in patients with lower pole calyx stones.
    Matched MeSH terms: Patient Positioning*
  5. Tsan SEH, Ng KT, Lau J, Viknaswaran NL, Wang CY
    Braz J Anesthesiol, 2020;70(6):667-677.
    PMID: 33288219 DOI: 10.1016/j.bjan.2020.08.009
    OBJECTIVES: Positioning during endotracheal intubation (ETI) is critical to ensure its success. We aimed to determine if the ramping position improved laryngeal exposure and first attempt success at intubation when compared to the sniffing position.

    METHODS: PubMed, EMBASE, and Cochrane CENTRAL databases were searched systematically from inception until January 2020. Our primary outcomes included laryngeal exposure as measured by Cormack-Lehane Grade 1 or 2 (CLG 1/2), CLG 3 or 4 (CLG 3/4), and first attempt success at intubation. Secondary outcomes were intubation time, use of airway adjuncts, ancillary maneuvers, and complications during ETI.

    RESULTS: Seven studies met our inclusion criteria, of which 4 were RCTs and 3 were cohort studies. The meta-analysis was conducted by pooling the effect estimates for all 4 included RCTs (n = 632). There were no differences found between ramping and sniffing positions for odds of CLG 1/2, CLG 3/4, first attempt success at intubation, intubation time, use of ancillary airway maneuvers, and use of airway adjuncts, with evidence of high heterogeneity across studies. However, the ramping position in surgical patients is associated with increased likelihood of CLG 1/2 (OR = 2.05, 95% CI 1.26 to 3.32, p = 0.004) and lower likelihood of CLG 3/4 (OR = 0.49, 95% CI 0.30 to 0.79, p = 0.004), moderate quality of evidence.

    CONCLUSION: Our meta-analysis demonstrated that the ramping position may benefit surgical patients undergoing ETI by improving laryngeal exposure. Large scale well designed multicentre RCTs should be carried out to further elucidate the benefits of the ramping position in the surgical and intensive care unit patients.

    Matched MeSH terms: Patient Positioning/methods*
  6. Tan S, Suraya A, Sa'don S, Ruzi A, Zahiah M
    Biomed Imaging Interv J, 2010 Apr-Jun;6(2):e16.
    PMID: 21611037 MyJurnal DOI: 10.2349/biij.6.2.e16
    The authors propose a musculoskeletal (MSK) magnetic resonance imaging (MRI) protocol using selected sequences for common orthopaedic indications. Selected sequences allow optimal visualisation of the indicated pathology while screening for other common conditions. The authors emphasise the need for standard positioning of the patient and standard orientation of scan planes to facilitate comparison with follow-up scans.
    Matched MeSH terms: Patient Positioning
  7. Yezid NH, Poh K, Md Noor J, Arshad A
    BMJ Case Rep, 2019 Aug 10;12(8).
    PMID: 31401573 DOI: 10.1136/bcr-2019-230201
    Managing the difficult airway presents a great challenge to anaesthesiologists and emergency physicians. Although there are many methods and scoring systems available to predict and anticipate difficult airway, the dictum in emergency airway is to always expect the unexpected. We have encountered a novel simple method of improving laryngoscopic view in difficult airway. We report four cases of difficult airway encountered in our district hospital from November 2017 to December 2018, in which intubation was performed using a simple manoeuvre called supine left head rotation (LeHeR). In all these cases, LeHeR manoeuvre has proven to be successful after more than a single attempt at intubation using various methods. The manoeuvre improves drastically the laryngoscopic view of Cormack-Lehane from 3B and 4 to 1 and 2.
    Matched MeSH terms: Patient Positioning/methods*
  8. Isa INC, Rahmat SMS, Dom SM, Kayun Z, Karim MKA
    J Xray Sci Technol, 2019;27(4):631-639.
    PMID: 31205011 DOI: 10.3233/XST-190491
    There are several factors that may contribute to the increase in radiation dose of CT including the use of unoptimized protocols and improper scanning technique. In this study, we aim to determine significant impact on radiation dose as a result of mis-centering during CT head examination. The scanning was performed by using Toshiba Aquilion 64 slices multi-detector CT (MDCT) scanner and dose were measured by using calibrated ionization chamber. Two scanning protocols of routine CT head; 120 kVp/ 180 mAs and 100 kVp/ 142 mAs were used represent standard and low dose, respectively. As reference measurement, the dose was first measured on standard cylindrical polymethyl methacrylate (PMMA) phantom that positioned at 104 cm from the floor (reference isocenter). The positions then were varied to simulate mis-centering by 5 cm from isocenter, superiorly and inferiorly at 109 cm, 114 cm, 119 cm, 124 cm and 99 cm, 94 cm, 89 cm, 84 cm, respectively. Scanning parameter and dose information from the console were recorded for the radiation effective dose (E) measurement. The highest mean CTDIvol value for MCS and MCI were 105.06 mGy (at +10 cm) and 105.51 mGy (at - 10 cm), respectively which differed significantly (p patient centering at the isocenter of CT gantry, so that CT optimization practice can be achieved.
    Matched MeSH terms: Patient Positioning*
  9. Tan CE, Hi MY, Azmi NS, Ishak NK, Mohd Farid FA, Abdul Aziz AF
    Cureus, 2020 Mar 24;12(3):e7390.
    PMID: 32337117 DOI: 10.7759/cureus.7390
    Background Most family caregivers of stroke patients in Malaysia do not receive adequate prior preparation or training. This study aimed to determine levels of patient positioning knowledge and caregiving self-efficacy among caregivers of stroke patients. Methods This cross-sectional study was conducted at an urban teaching hospital involving 128 caregivers of stroke patients. The caregivers were conveniently sampled and completed the data collection forms, which comprised their socio-demographic data, patients' functional status, the Caregiving Knowledge For Stroke Questionnaire: Patient Positioning (CKQ-My© Patient Positioning) to measure caregiver's knowledge on patient positioning, and the Family Caregiver Activation Tool (FCAT©) to measure caregivers' self-efficacy in managing the patient. Descriptive and multivariate inferential statistics were used for data analysis. Results Among the caregivers sampled, 87.3% had poor knowledge of positioning (mean score 14.9 ± 4.32). The mean score for FCAT was 49.7 ± 6.0 from a scale of 10 to 60. There was no significant association between knowledge on positioning and self-efficacy. Multiple linear regression showed that caregivers' age (B = 0.146, p = 0.003) and caregiver training (B = 3.302, p = 0.007) were independently associated with caregivers' self-efficacy. Conclusion Caregivers' knowledge on the positioning of stroke patients was poor, despite a fairly good level of self-efficacy. Older caregivers and receiving caregiver training were independently associated with better caregiver self-efficacy. This supports the provision of caregiver training to improve caregiver self-efficacy.
    Matched MeSH terms: Patient Positioning
  10. Kapur A, Kapur V
    Malays J Med Sci, 2020 May;27(3):143-149.
    PMID: 32684815 DOI: 10.21315/mjms2020.27.3.15
    Technological advances in the field of surgery and medicine have increased the demand for minimally invasive surgery manifold. Robot assisted surgery is gaining popularity, overcoming the flaws of laparoscopic techniques; with improved surgical precision. The conservative nature of anaesthesia care has to face the challenges with respect to patient positioning, bulkiness of the operating system and being positioned far and away from the patient. Anaesthesiologist's commitment to be the 'best man' for the patient during the perioperative period mandates him to familiarise with these challenges of robot assisted surgical system and provide best possible anaesthetic care and ensure patient safety. In this article, a systematic review of the development of surgical robots and the consideration of unique anaesthetic concerns thereof have been undertaken as any new technology is known to be accompanied by its risks and technical perplexity.
    Matched MeSH terms: Patient Positioning
  11. Osman A, Wan Chuan T, Ab Rahman J, Via G, Tavazzi G
    Eur J Emerg Med, 2018 Oct;25(5):322-327.
    PMID: 28509710 DOI: 10.1097/MEJ.0000000000000471
    OBJECTIVE: The aim of this study was to evaluate a novel pericardiocentesis technique using an in-plane parasternal medial-to-lateral approach with the use of a high-frequency probe in patients with cardiac tamponade.

    BACKGROUND: Echocardiography is pivotal in the diagnosis of pericardial effusion and tamponade physiology. Ultrasound guidance for pericardiocentesis is currently considered the standard of care. Several approaches have been described recently, which differ mainly on the site of puncture (subxiphoid, apical, or parasternal). Although they share the use of low-frequency probes, there is absence of complete control of needle trajectory and real-time needle visualization. An in-plane and real-time technique has only been described anecdotally.

    METHODS AND RESULTS: A retrospective analysis of 11 patients (63% men, mean age: 37.7±21.2 years) presenting with cardiac tamponade admitted to the tertiary-care emergency department and treated with parasternal medial-to-lateral in-plane pericardiocentesis was carried out. The underlying causes of cardiac tamponade were different among the population. All the pericardiocentesis were successfully performed in the emergency department, without complications, relieving the hemodynamic instability. The mean time taken to perform the eight-step procedure was 309±76.4 s, with no procedure-related complications.

    CONCLUSION: The parasternal medial-to-lateral in-plane pericardiocentesis is a new technique theoretically free of complications and it enables real-time monitoring of needle trajectory. For the first time, a pericardiocentesis approach with a medial-to-lateral needle trajectory and real-time, in-plane, needle visualization was performed in a tamponade patient population.

    Matched MeSH terms: Patient Positioning/methods
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links