Displaying 1 publication

Abstract:
Sort:
  1. Abdul Keyon AS, Guijt RM, Bolch CJ, Breadmore MC
    J Chromatogr A, 2014 Oct 17;1364:295-302.
    PMID: 25223612 DOI: 10.1016/j.chroma.2014.08.074
    The accumulation of paralytic shellfish toxins (PSTs) in contaminated shellfish is a serious health risk making early detection important to improve shellfish safety and biotoxin management. Capillary electrophoresis (CE) has been proven as a high resolution separation technique compatible with miniaturization, making it an attractive choice in the development of portable instrumentation for early, on-site detection of PSTs. In this work, capillary zone electrophoresis (CZE) with capacitively coupled contactless conductivity detector (C(4)D) and UV detection were examined with counter-flow transient isotachophoresis (tITP) to improve the sensitivity and deal with the high conductivity sample matrix. The high sodium concentration in the sample was used as the leading ion while l-alanine was used as the terminating electrolyte (TE) and background electrolyte (BGE) in which the toxins were separated. Careful optimization of the injected sample volume and duration of the counter-flow resulted in limit of detections (LODs) ranging from 74.2 to 1020 ng/mL for tITP-CZE-C(4)D and 141 to 461 ng/mL for tITP-CZE-UV, an 8-97 fold reduction compared to conventional CZE. The LODs were adequate for the analysis of PSTs in shellfish samples close to the regulatory limit. Intra-day and inter-day repeatability values (percentage relative standard deviation, n=3) of tITP-CZE-C(4)D and tITP-CZE-UV methods for both migration time and peak height were in the range of 0.82-11% and 0.76-10%, respectively. The developed method was applied to the analysis of a contaminated mussel sample and validated against an Association of Official Analytical Chemists (AOAC)-approved method for PSTs analysis by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) after pre-column oxidation of the sample. The method presented has potential for incorporation in to field-deployable devices for the early detection of PSTs on-site.
    Matched MeSH terms: Mollusk Venoms/analysis*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links