Displaying all 9 publications

Abstract:
Sort:
  1. Imran Y, Azman MZN
    Med J Malaysia, 2005 Aug;60(3):358-9.
    PMID: 16379192
    Cases of retained surgical guaze are rarely reported because of medico-legal and professional implications. Retained gauze for a period of more than 10 years is even rarer. A case of retained surgical gauze for 11 years, an accidental finding from a plain radiograph of a patient who had sustained proximal femoral fracture, is reported. A review of other reported cases is presented.
    Matched MeSH terms: Femoral Fractures/radiography*
  2. Sidhu JS, Kadni T
    Med J Malaysia, 1988 Jun;43(2):117-24.
    PMID: 3237127
    Matched MeSH terms: Femoral Fractures/radiography*
  3. Tan WJ, Kwan MK, Deepak AS, Saw A, Peng BC, Jalalullah W
    Med J Malaysia, 2006 Dec;61 Suppl B:18-22.
    PMID: 17600988
    Fracture of the femur is most commonly treated with interlocking nailing. We conducted this study to describe and analyze the size of femoral interlocking nails used in our local population. This is a retrospective study on reamed intramedullary interlocking nailing procedures performed between 1st July 1998 and 30th June 2003. Demographic data, the diameter and length of femoral nails used were obtained from patient's medical record. A total of 267 procedures were included. The most common diameter used was 10 mm (56.9%), followed by 11 mm (27.0%) and 12 mm (13.1%). Only 2.6% of the nails were less than 10 mm in diameter. The most common nail length was 38 cm (31.1%), followed by 36 cm (24.9%) and 40 cm (19.5%). The longest nail used was 46 cm while the shortest 32 cm. The most commonly used femoral nails were of 10 mm diameter with the length ranging from 36 to 40 cm, which is smaller than those reported in the English literature. Nails with diameter smaller than 10 mm were required in 2.6% of patients.
    Matched MeSH terms: Femoral Fractures/radiography
  4. Muzaffar TST, Imran Y, Iskandar MA, Zakaria A
    Med J Malaysia, 2005 Jul;60 Suppl C:26-9.
    PMID: 16381279
    Femoral interlocking nailing requires fluoroscopic assistance for insertion of the nail and distal screws. In this study, scattered radiation to the eye and hand of the operating surgeon was measured during the procedure. Thermo-luminescent dosimeter (TLD) was used to quantify the dose received by the surgeon. The mean radiation exposure time during the procedure was 3.89 minutes. The mean scattered radiation doses to the hand and eye were 0.27 mSv and 0.09 mSv per procedure respectively. These very low doses have made a surgeon very unlikely to receive more than the recommended annual dose limit set by the National Council on Radiological Protection.
    Matched MeSH terms: Femoral Fractures/radiography
  5. Teh PH, Krishnamoorty S
    Med J Malaysia, 1986 Sep;41(3):205-12.
    PMID: 3670136
    A retrospective study of 34 patients with supracondylar-condylar fractures of the femur admitted to the Alexandra Hospital, Singapore, from January 1979 to December 1983 was carried out. These fractures were surgically treated by AO principles and fixation, and the surgery performed mainly by the two authors. Using strict criteria adopted from Schatzker of Toronto, 1 it was found that 62% of patients had excellent/ good results. The importance of treating supracondylar-condylar fractures by AO principles and fixation is emphasised.
    Matched MeSH terms: Femoral Fractures/radiography
  6. Baharuddin M, Sharaf I
    Med J Malaysia, 2001 Dec;56 Suppl D:54-6.
    PMID: 14569768
    We report a rare case of an acute haematogenous osteomyelitis of the femur in a five-year-old boy following a closed fracture of the femur. Because of its rare occurrence, the diagnosis of osteomyelitis was missed initially. He presented with a groin abscess seven weeks after injury. He was treated with external fixation, repeated debridements and intravenous antibiotics. Culture grew Staphylococcus aureus. The latest follow-up one-year after the injury showed resolution of the infection and union of the fracture. The range of knee movement is limited from 0-90 degrees due to quadriceps contracture.
    Matched MeSH terms: Femoral Fractures/radiography
  7. Shuid AN, Mohamad S, Mohamed N, Fadzilah FM, Mokhtar SA, Abdullah S, et al.
    J Orthop Res, 2010 Dec;28(12):1651-6.
    PMID: 20572125 DOI: 10.1002/jor.21180
    Fracture healing is a complex process, which is further complicated if the bone is osteoporotic. Calcium is one of the important minerals in bone and has been found to prevent osteoporosis but its role in fracture healing of osteoporotic bone is still unclear. We carried out a study on the effects of calcium supplementation on the late phase healing of fractured osteoporotic bone using an ovariectomized rat model. Twenty-four female Sprague-Dawley rats were divided into three groups: sham-operated (SO), ovariectomized-control (OVXC), and ovariectomized + calcium supplements (Ca). The right femurs of all the rats were fractured at mid-epiphysis and a K-wire was inserted for internal fixation. After 2 months of treatment, the rats were sacrificed and the femora were dissected out for radiological and biomechanical assessment. As expected, osteoporosis resulted in impaired healing as shown by the poor radiological and biomechanical properties of the OVXC group. CT scans showed significantly lower callus volumes in the SO and Ca groups compared to the OVXC group. Radiological scoring of fracture healing and callus staging of the SO and Ca groups were better than the OVXC group. However, the biomechanical parameters of the Ca group were significantly lower than the SO group and similar to the OVXC group. Therefore, calcium supplements may appear to improve fracture healing of osteoporotic bone but failed to improve strength.
    Matched MeSH terms: Femoral Fractures/radiography
  8. Lee JK
    Int J Rheum Dis, 2009 Jul;12(2):149-54.
    PMID: 20374333 DOI: 10.1111/j.1756-185X.2009.01396.x
    Antiresorptive agents have been used as primary or first-line therapy in managing patients with osteoporosis. Bisphosphonates in particular are used widely to reduce bone resorption, increase bone mineral density, improve bone quality and therefore reduce fracture risk. However, prolonged use of bisphosphonates may cause over-suppression of bone resorption, leading on to accumulation of micro-damage in bone. This in turn might lead on to atypical femoral fractures. A patient treated with alendronate sodium for 8 years, and presenting with bilateral atypical femoral diaphyseal fractures is reported. X-rays of both femurs showed typical horizontal fracture line involving the thick lateral cortex with short oblique fracture pattern over the medial cortex. This fracture pattern was further confirmed with intra-operative examination of the fracture ends. Histopathological examination of the endocortical fragment removed from the proximal fracture end showed absence of osteoclasts and osteoblasts. Bone mineral density with dual energy X-ray absorptiometry (DXA) scan showed osteopenia over the femoral neck. Blood investigations did not show significant abnormalities. Bone turnover marker levels were not reliable, as presence of fracture might have altered the marker levels. Both femoral fractures united well. The patient reported here had complete pictures on X-ray examination, intra-operative findings, histopathological examination, DXA, as well as blood test results. Complete data should be collected from patients treated with alendronate sodium presenting with atypical femoral fractures to show any link between the use of alendronate sodium with atypical fracture of femur.
    Matched MeSH terms: Femoral Fractures/radiography
  9. Baskaran S, Nahulan T, Kumar AS
    Med J Malaysia, 2004 Dec;59 Suppl F:72-4.
    PMID: 15941170
    This is the first time we encountered a peculiar case of osteomyelitis complicating a closed fracture. The patient was a 38 year-old lady who presented just like any other patient with a closed fracture of the right femur. Intraoperatively we were surprised to find pus from the fracture site. This not only changed the surgical management but altered the subsequent outcome as well.
    Matched MeSH terms: Femoral Fractures/radiography
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links