Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Al Azzam KM, Saad B, Aboul-Enein HY
    Biomed Chromatogr, 2010 Sep;24(9):948-53.
    PMID: 20082285 DOI: 10.1002/bmc.1390
    Capillary zone electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE-C(4)D) has been employed for the determination of atenolol and amiloride in pharmaceutical formulations. Acetic acid (150 mm) was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature and injection time) was studied. Non-UV-absorbing L-valine was used as internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28 degrees C, 25 kV and using hydrodynamic injection (25 s). The separation was effected in an uncoated fused-silica capillary (75 microm, i.d. x 52 cm). The CE-C(4)D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 5-250 microg/mL for the studied analytes. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol and amiloride in different pharmaceutical tablet formulations.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  2. John AS, Sidek MM, Thang LY, Sami S, Tey HY, See HH
    J Chromatogr A, 2021 Feb 08;1638:461868.
    PMID: 33453653 DOI: 10.1016/j.chroma.2020.461868
    One of the major drawbacks of electrophoresis in both capillary and microchip is the unsatisfactory sensitivity. Online sample preconcentration techniques can be regarded as the most common and powerful approaches commonly applied to enhance overall detection sensitivity. While the advances of various online preconcentration strategies in capillary and microchip employing aqueous background electrolytes are well-reviewed, there has been limited discussion of the feasible preconcentration techniques specifically developed for capillary and microchip using nonaqueous background electrolytes. This review provides the first consolidated overview of various online preconcentration techniques in nonaqueous capillary and microchip electrophoresis, covering the period of the last two decades. It covers developments in the field of sample stacking, isotachophoresis, and micellar-based stacking. Attention is also given to multi-stacking strategies that have been used for nonaqueous electrophoresis.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  3. Al Azzam KM, Saad B, Aboul-Enein HY
    Electrophoresis, 2010 Sep;31(17):2957-63.
    PMID: 20690150 DOI: 10.1002/elps.201000266
    Binding constants for the enantiomers of modafinil with the negatively charged chiral selector sulfated-β-CD (S-β-CD) using CE technique is presented. The calculations of the binding constants employing three different linearization plots (double reciprocal, X-reciprocal and Y-reciprocal) were performed from the electrophoretic mobility values of modafinil enantiomers at different concentrations of S-β-CD in the BGE. The highest inclusion affinity of the modafinil enantiomers were observed for the S-enantiomer-S-β-CD complex, in agreement with the computational calculations performed previously. Binding constants for each enantiomer-S-β-CD complex at different temperatures, as well as thermodynamic parameters for binding, were calculated. Host-guest binding constants using the double reciprocal fit showed better linearity (r(2)>0.99) at all temperatures studied (15-30°C) and compared with the other two fit methods. The linear van't Hoff (15-30°C) plot obtained indicated that the thermodynamic parameters of complexation were temperature dependent for the enantiomers.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  4. Surugau N, Urban PL
    J Sep Sci, 2009 Jun;32(11):1889-906.
    PMID: 19479769 DOI: 10.1002/jssc.200900071
    This article reviews progress in the application of electrophoretic techniques for the separation of nanoparticles. Numerous types of nanoparticles have recently been synthesised and integrated into different products and procedures. Consequently, analytical methods for the efficient characterisation of nanoparticles are now required. Several studies have revealed that gel electrophoresis can readily be used for separating nanoparticles according to their size or shape. However, many other studies focused on separation of nanoparticles by CE. In some cases nanoparticles could be separated by CZE, simply using pure buffer as the BGE. In other studies, buffer additives (most often SDS) were used, enabling fast separations of metallic nanoparticles by size. Other CE methods also allowed for separation of nanoparticle conjugates with biomolecules. Dielectrophoresis is yet another electrophoretic technique useful in separation and characterisation of nanoparticles; particularly nanotubes. Detection methods often used after electrophoretic separation include UV/Vis absorption and fluorescence spectroscopy. Examples of recent and relevant older reports are presented here. The authors conclude that electrophoretic methods for nanoanalysis can provide inexpensive and efficient tools for quality assurance and safety control; and as a consequence, they can augment transfer of nanotechnologies from research to industry.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  5. Thang LY, See HH, Quirino JP
    Electrophoresis, 2016 05;37(9):1166-9.
    PMID: 26873060 DOI: 10.1002/elps.201600010
    Micelle to solvent stacking was implemented for the recently established NACE-C(4) D method to determine tamoxifen and its metabolites in standard samples and human plasma of breast cancer patients. For stacking, the standard samples and extract after liquid-liquid extraction (LLE) were prepared in methanol and the resulting sample solution was pressure injected after a micellar plug of SDS. Factors that affected the stacking such as SDS concentration, micelle, and sample plug length were examined. The sensitivity enhancement factor (peak height from stacking/peak height from typical injection of sample in BGE) was 15-22. The method detection limits with LLE were in the range of 5-10 ng/mL, which was lower than the established method (where the LLE extract was also prepared in methanol) with reported method detection limits of 25-40 ng/mL. The intraday and interday repeatability were in the range of 1.0-3.4% and 3.8-6.5%, respectively.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  6. Wan Ibrahim WA, Arsad SR, Maarof H, Sanagi MM, Aboul-Enein HY
    Chirality, 2015 Mar;27(3):223-7.
    PMID: 25523071 DOI: 10.1002/chir.22416
    This work aimed to develop a chiral separation method of ketoconazole enantiomers using electrokinetic chromatography. The separation was achieved using heptakis (2, 3, 6-tri-O-methyl)-β-cyclodextrin (TMβCD), a commonly used chiral selector (CS), as it is relatively inexpensive and has a low UV absorbance in addition to an anionic surfactant, sodium dodecyl sulfate (SDS). The influence of TMβCD concentration, phosphate buffer concentration, SDS concentration, buffer pH, and applied voltage were investigated. The optimum conditions for chiral separation of ketoconazole was achieved using 10 mM phosphate buffer at pH 2.5 containing 20 mM TMβCD, 5 mM SDS, and 1.0% (v/v) methanol with an applied voltage of 25 kV at 25 °C with a 5-s injection time (hydrodynamic injection). The four ketoconazole stereoisomers were successfully resolved for the first time within 17 min (total analysis time was 28 min including capillary conditioning). The migration time precision of this method was examined to give repeatability and reproducibility with RSDs ≤5.80% (n =3) and RSDs ≤8.88% (n =9), respectively.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  7. Abdul Keyon AS, Guijt RM, Bolch CJ, Breadmore MC
    J Chromatogr A, 2014 Oct 17;1364:295-302.
    PMID: 25223612 DOI: 10.1016/j.chroma.2014.08.074
    The accumulation of paralytic shellfish toxins (PSTs) in contaminated shellfish is a serious health risk making early detection important to improve shellfish safety and biotoxin management. Capillary electrophoresis (CE) has been proven as a high resolution separation technique compatible with miniaturization, making it an attractive choice in the development of portable instrumentation for early, on-site detection of PSTs. In this work, capillary zone electrophoresis (CZE) with capacitively coupled contactless conductivity detector (C(4)D) and UV detection were examined with counter-flow transient isotachophoresis (tITP) to improve the sensitivity and deal with the high conductivity sample matrix. The high sodium concentration in the sample was used as the leading ion while l-alanine was used as the terminating electrolyte (TE) and background electrolyte (BGE) in which the toxins were separated. Careful optimization of the injected sample volume and duration of the counter-flow resulted in limit of detections (LODs) ranging from 74.2 to 1020 ng/mL for tITP-CZE-C(4)D and 141 to 461 ng/mL for tITP-CZE-UV, an 8-97 fold reduction compared to conventional CZE. The LODs were adequate for the analysis of PSTs in shellfish samples close to the regulatory limit. Intra-day and inter-day repeatability values (percentage relative standard deviation, n=3) of tITP-CZE-C(4)D and tITP-CZE-UV methods for both migration time and peak height were in the range of 0.82-11% and 0.76-10%, respectively. The developed method was applied to the analysis of a contaminated mussel sample and validated against an Association of Official Analytical Chemists (AOAC)-approved method for PSTs analysis by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) after pre-column oxidation of the sample. The method presented has potential for incorporation in to field-deployable devices for the early detection of PSTs on-site.
    Matched MeSH terms: Electrophoresis, Capillary/methods
  8. Keyon AS, Guijt RM, Gaspar A, Kazarian AA, Nesterenko PN, Bolch CJ, et al.
    Electrophoresis, 2014 May;35(10):1496-503.
    PMID: 24591173 DOI: 10.1002/elps.201300353
    Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre- or postcolumn oxidation for fluorescence detection (HPLC-FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on-site monitoring. In this study, CE methods were developed for C(4) D, FLD, UV absorption detection, and MS-making this first report of C(4) D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE-UV and CZE-C(4) D methods provide better resolution, selectivity, and separation efficiency compared to CZE-MS and MEKC-FLD. The sensitivity of the CZE-C(4) D and MEKC-FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE-C(4) D and 60.9 to 104 ng/mL for MEKC-FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE-C(4) D and MEKC-FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE-C(4) D method suffered from significant interferences from the shellfish matrix, MEKC-FLD was successfully used for PST screening of a periodate-oxidized mussel sample, with results confirmed by HPLC-FLD. This confirms the potential of MEKC-FLD for screening of PSTs in shellfish samples.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  9. AL Azzam KM, Aboul-Enein HY
    Methods Mol Biol, 2013;919:67-78.
    PMID: 22976091 DOI: 10.1007/978-1-62703-029-8_7
    Capillary electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE-C(4)D) has been employed for the determination of the β-blocker drugs (atenolol and amiloride) in pharmaceutical formulations. 150 mM acetic acid was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature, and injection time) was studied. Non-UV absorbing L-valine was used as an internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28 °C, 25 kV, and using hydrodynamic injection (25 s). The separation was effected in a bare fused-silica capillary 75 μm × 52 cm. The CE-C(4)D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision, and selectivity. Calibration curves were linear over the range 5-250 μg mL(-1) for the studied analytes. The relative standard deviations of intra- and inter-day precisions of migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of the β-blocker drugs in different pharmaceutical tablets.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  10. Al Azzam KM, Saad B, Adnan R, Aboul-Enein HY
    Anal Chim Acta, 2010 Aug 3;674(2):249-55.
    PMID: 20678638 DOI: 10.1016/j.aca.2010.06.046
    A capillary electrophoretic method for the separation of the enantiomers of both ofloxacin and ornidazole is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixtures was achieved in less than 16 min with resolution factors Rs=5.45 and 6.28 for ofloxacin and ornidazole enantiomers, respectively. Separation was conducted using a bare fused-silica capillary and a background electrolyte (BGE) of 50 mM H(3)PO(4)-1 M tris solution; pH 1.85; containing 30 mg mL(-1) of sulfated-beta-cyclodextrin (S-beta-CD). The separation was carried out in reversed polarity mode at 25 degrees C, 18 kV, detection wavelength at 230 nm and using hydrodynamic injection for 15 s. Acceptable validation criteria for selectivity, linearity, precision, and accuracy were studied. The limits of detection (LOD) and limits of quantitation (LOQ) of the enantiomers (ofloxacin enantiomer 1 (OF-E1), ofloxacin enantiomer 2 (OF-E2), ornidazole enantiomer 1 (OR-E1) and ornidazole enantiomer 2 (OR-E2)) were (0.52, 0.46, 0.54, 0.89) and (1.59, 1.40, 3.07, 2.70) microg mL(-1), respectively. The proposed method was successfully applied to the assay of enantiomers of both ofloxacin and ornidazole in pharmaceutical formulations. The computational calculations for the enantiomeric inclusion complexes rationalized the reasons for the different migration times between the ofloxacin and ornidazole enantiomers.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  11. Sanagi MM, Miskam M, Wan Ibrahim WA, Hermawan D, Aboul-Enein HY
    J Sep Sci, 2010 Jul;33(14):2131-9.
    PMID: 20549667 DOI: 10.1002/jssc.201000172
    A three-phase hollow fiber liquid-phase microextraction method coupled with CE was developed and used for the determination of partition coefficients and analysis of selected nitrophenols in water samples. The selected nitrophenols were extracted from 14 mL of aqueous solution (donor solution) with the pH adjusted to pH 3 into an organic phase (1-octanol) immobilized in the pores of the hollow fiber and finally backextracted into 40.0 microL of the acceptor phase (NaOH) at pH 12.0 located inside the lumen of the hollow fiber. The extractions were carried out under the following optimum conditions: donor solution, 0.05 M H(3)PO(4), pH 3.0; organic solvent, 1-octanol; acceptor solution, 40 microL of 0.1 M NaOH, pH 12.0; agitation rate, 1050 rpm; extraction time, 15 min. Under optimized conditions, the calibration curves for the analytes were linear in the range of 0.05-0.30 mg/L with r(2)>0.9900 and LODs were in the range of 0.01-0.04 mg/L with RSDs of 1.25-2.32%. Excellent enrichment factors of up to 398-folds were obtained. It was found that the partition coefficient (K(a/d)) values were high for 2-nitrophenol, 3-nitrophenol, 4-nitrophenol, 2,4-dinitrophenol and 2,6-dinitrophenol and that the individual partition coefficients (K(org/d) and K(a/org)) promoted efficient simultaneous extraction from the donor through the organic phase and further into the acceptor phase. The developed method was successfully applied for the analysis of water samples.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  12. See KL, Elbashir AA, Saad B, Ali AS, Aboul-Enein HY
    Biomed Chromatogr, 2009 Dec;23(12):1283-90.
    PMID: 19488980 DOI: 10.1002/bmc.1251
    A simple, rapid and validated capillary electrophoretic method has been developed for the separation and determination of ofloxacin and ornidazole in pharmaceutical formulations with detection at 230 nm. Optimal conditions for the quantitative separations were investigated. Analysis times shorter than 4 min were obtained using a background electrolyte solution consisting of 25 mmol/L phosphoric acid adjusted with 1 M Tris buffer to pH 8.5, with hydrodynamic injection of 5 s and 20 kV separation voltage. The validation criteria for accuracy, precision, linearity and limits of detection and quantitation were examined and discussed. An excellent linearity was obtained in concentration range 25-250 microg/mL. The detection limits for ofloxacin and ornidazole were 1.03 +/- 0.11 and 1.80 +/- 0.06 microg/mL, respectively. The proposed method has been applied for the analysis of ofloxacin and ornidazole both individually and in a combined dosage tablet formulation. The proposed validated method showed recoveries between 96.16 and 105.23% of the nominal contents.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  13. See HH, Hauser PC, Ibrahim WA, Sanagi MM
    Electrophoresis, 2010 Jan;31(3):575-82.
    PMID: 20119968 DOI: 10.1002/elps.200900380
    Rapid and direct online preconcentration followed by CE with capacitively coupled contactless conductivity detection (CE-C(4)D) is evaluated as a new approach for the determination of glyphosate, glufosinate (GLUF), and aminophosphonic acid (AMPA) in drinking water. Two online preconcentration techniques, namely large volume sample stacking without polarity switching and field-enhanced sample injection, coupled with CE-C(4)D were successfully developed and optimized. Under optimized conditions, LODs in the range of 0.01-0.1 microM (1.7-11.1 microg/L) and sensitivity enhancements of 48- to 53-fold were achieved with the large volume sample stacking-CE-C(4)D method. By performing the field-enhanced sample injection-CE-C(4)D procedure, excellent LODs down to 0.0005-0.02 microM (0.1-2.2 microg/L) as well as sensitivity enhancements of up to 245- to 1002-fold were obtained. Both techniques showed satisfactory reproducibility with RSDs of peak height of better than 10%. The newly established approaches were successfully applied to the analysis of glyphosate, glufosinate, and aminophosphonic acid in spiked tap drinking water.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  14. Al Azzam KM, Saad B, Aboul-Enein HY
    Biomed Chromatogr, 2010 Sep;24(9):977-81.
    PMID: 20066730 DOI: 10.1002/bmc.1395
    Capillary zone electrophoresis methods for the simultaneous determination of the beta-blocker drugs, atenolol, chlorthalidone and amiloride, in pharmaceutical formulations have been developed. The influences of several factors (buffer pH, concentration, applied voltage, capillary temperature and injection time) were studied. Using phenobarbital as internal standard, the analytes were all separated in less than 4 min. The separation was carried out in normal polarity mode at 25 degrees C, 25 kV and using hydrodynamic injection (10 s). The separation was effected in an uncoated fused-silica capillary (75 mum i.d. x 52 cm) and a background electrolyte of 25 mm H(3)PO(4) adjusted with 1 m NaOH solution (pH 9.0) and detection at 198 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 1-250 microg/mL for atenolol and chlorthalidone and from 2.5-250 microg/mL for amiloride. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol, chlorthalidone and amiloride in various pharmaceutical tablets formulations.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  15. Elbashir AA, Suliman FE, Saad B, Aboul-Enein HY
    Talanta, 2009 Feb 15;77(4):1388-93.
    PMID: 19084654 DOI: 10.1016/j.talanta.2008.09.029
    A capillary electrophoretic method for the separation of the aminoglutethimide (AGT) enantiomers using methylated-beta-cyclodextrin (M-beta-CD) as chiral selector is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixture was achieved in less than 9 min with resolution factor Rs=2.1, using a fused-silica capillary and a background electrolyte (BGE) of tris-phosphate buffer solution (50 mmol L(-1), pH 3.0) containing 30 mgm L(-1) of M-beta-CD. The separation was carried out in normal polarity mode at 25 degrees C, 16 kV and using hydrostatic injection. Acceptable validation criteria for selectivity, linearity, precision, and accuracy/recovery were included. The proposed method was successfully applied to the assay of AGT enantiomers in pharmaceutical formulations. The computational calculations for the inclusion complexes of the R- and S-AGT-M-beta-CD rationalized the reasons for the different migration times between the AGT enantiomers.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  16. Elbashir AA, Saad B, Ali AS, Saleh MI
    J AOAC Int, 2008 6 24;91(3):536-41.
    PMID: 18567298
    A capillary electrophoresis (CE) method has been developed that allows the separation and estimation of primaquine enantiomers using hydroxypropyl-gamma-cyclodextrin (HP-gamma -CD) as a chiral selector. The influence of chemical and instrumental parameters on the separation, such as type and concentration of CD, buffer concentration, buffer pH, applied voltage, capillary temperature, and injection time, were investigated. Good separation of the racemic mixture of primaquine was achieved using a fused-silica capillary (52.5 cm effective length x 50 microm id) and a background electrolyte composed of tris-phosphate buffer solution (50 mM, pH 2.5) containing 15 mM HP-gamma-CD as a chiral selector. The recommended applied voltage, capillary temperature, and injection time were 15 kV, 25 degrees C, and 6 s, respectively. Within-day and interday reproducibility of peak area and migration time gave relative standard deviation values ranging from 1.05-3.30%. Good recoveries (range of 96.8-104.9%) were obtained from the determination of placebos that were spiked with 0.25-1.00 mg/L primaquine. The proposed CE method was successfully applied to the assay of primaquine diphosphate in pharmaceutical formulations (tablets).
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  17. Chik Z, Johnston A, Tucker AT, Burn RT, Perrett D
    Biomed Chromatogr, 2007 Aug;21(8):775-9.
    PMID: 17497758
    A fast and simple capillary zone electrophoresis method was developed and validated for the determination of lidocaine in skin using tape samples. Separation was performed in a 350 mm (265 mm to window) x 50 microm i.d. fused silica capillary using a background electrolyte of phosphoric acid-Tris pH 2.5. The extraction of lidocaine from tape samples was achieved using methanol, which was diluted to 50% with water before injection. Procaine was the internal standard. The migration times for procaine and lidocaine were 2.9 and 3.2 min, respectively. The limit of quantification for lidocaine was 50 microg, with signal to noise ratio greater than 10. The calibration curve was linear from 50 to 1000 microg with r(2) greater than 0.99. The CV for both within- and between-assay imprecision and the percentage of inaccuracy for the quality control samples including lower and upper limits of quantitation were 97%. The accuracy and selectivity of this method allowed the measurement of lidocaine in tape samples obtained from a skin tape stripping study of local anesthetics in healthy subjects.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  18. Abdul Karim N', Wan Ibrahim WA, Sanagi MM, Abdul Keyon AS
    Electrophoresis, 2016 10;37(20):2649-2656.
    PMID: 27434368 DOI: 10.1002/elps.201600207
    Online preconcentration using electrokinetic supercharging (EKS) was proposed to enhance the sensitivity of separation for endocrine disrupting chemical (methylparaben (MP)) and phenolic pollutants (2-nitrophenol (NP) and 4-chlorophenol (CP)) in water sample. Important EKS and separation conditions such as the concentration of BGE; the choice of terminating electrolyte (TE); and the injection time of leading electrolyte (LE), sample, and TE were optimized. The optimum EKS-CE conditions were as follows: BGE comprising of 12 mM sodium tetraborate pH 10.1, 100 mM sodium chloride as LE hydrodynamically injected at 50 mbar for 30 s, electrokinetic injection (EKI) of sample at -3 kV for 200 s, and 100 mM CHES as TE hydrodynamically injected at 50 mbar for 40 s. The separation was conducted at negative polarity mode and UV detection at 214 nm. Under these conditions, the sensitivity of analytes was enhanced from 100- to 737-fold as compared to normal CZE with hydrodynamic injection, giving LOD of 4.89, 5.29, and 53 μg/L for MP, NP and CP, respectively. The LODs were adequate for the analysis of NP and CP in environmental water sample having concentration at or lower than their maximum admissible concentration limit (240 and 2000 μg/L for NP and CP). The LOD of MP can be suitable for the analysis of MP exists at mid-microgram per liter level, even though the LOD was slightly higher than the concentration usually found in water samples (from ng/L to 1 μg/L). The method repeatabilities (%RSD) were in the range of 1.07-2.39% (migration time) and 8.28-14.0% (peak area).
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  19. Breadmore MC, Wuethrich A, Li F, Phung SC, Kalsoom U, Cabot JM, et al.
    Electrophoresis, 2017 01;38(1):33-59.
    PMID: 27678139 DOI: 10.1002/elps.201600331
    One of the most cited limitations of capillary (and microchip) electrophoresis is the poor sensitivity. This review continues to update this series of biennial reviews, first published in Electrophoresis in 2007, on developments in the field of on-line/in-line concentration methods in capillaries and microchips, covering the period July 2014-June 2016. It includes developments in the field of stacking, covering all methods from field amplified sample stacking and large volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  20. Chui MQ, Thang LY, See HH
    J Chromatogr A, 2017 Jan 20;1481:145-151.
    PMID: 28017568 DOI: 10.1016/j.chroma.2016.12.042
    A new approach based on the integration of the free liquid membrane (FLM) into electrokinetic supercharging (EKS) was demonstrated to be a new powerful tool used in order to enhance online preconcentration efficiency in capillary electrophoresis (CE). A small plug of water immiscible organic solvent was used as a membrane interface during the electrokinetic sample injection step in EKS in order to significantly enhance the analyte stacking efficiency. The new online preconcentration strategy was evaluated for the determination of paraquat and diquat present in the environmental water samples. The optimised FLM-EKS conditions employed were as follows: hydrodynamic injection (HI) of 20mM potassium chloride as leading electrolyte at 50mbar for 75s (3% of the total capillary volume) followed by the HI of tris(2-ethylhexyl) phosphate (TEHP) as FLM at a 1mm length (0.1% of the capillary volume). The sample was injected at 10kV for 360s, followed by the HI of 20mM cetyl trimethylammonium bromide (CTAB) as terminating electrolyte at 50mbar for 50s (2% of the total capillary volume). The separation was performed in 12mM ammonium acetate and 30mM NaCl containing 20% MeOH at +25kV with UV detection at 205nm. Under optimised conditions, the sensitivity was enhanced between 1500- and 1866-fold when compared with the typical HI at 50mbar for 50s. The detection limit of the method for paraquat and diquat was 0.15-0.20ng/mL, with RSDs below 5.5%. Relative recoveries in spiked river water were in the range of 95.4-97.5%. A comparison was also made between the proposed approach with sole preconcentration of the field-enhanced sample injection (FASI) and EKS in the absence of the FLM.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links