Displaying all 20 publications

Abstract:
Sort:
  1. Sachithanandan A, Abdul Muis J, Zurah Z, Mohd R
    Med J Malaysia, 2013 Dec;68(6):475-6.
    PMID: 24632918 MyJurnal
    No abstract available.
    Matched MeSH terms: Echocardiography, Transesophageal*
  2. Adi O, Apoo FN, Fong CP, Ahmad AH, Panebianco N
    Am J Emerg Med, 2023 Oct;72:224.e1-224.e4.
    PMID: 37500381 DOI: 10.1016/j.ajem.2023.07.037
    BACKGROUND: Superior vena cava syndrome (SVCS) is a malignancy-related emergency. It is caused by obstruction of blood flow in the superior vena cava (SVC) secondary to intraluminal thrombosis, external compression, or direct invasion of tumor.

    CASE SUMMARY: A 49-year-old male presented to the emergency department (ED) with acute hypoxemic respiratory failure. He was intubated and treated as pneumonia. Post-intubation, he became hypotensive, requiring fluid resuscitation and inotropic support. Resuscitative transesophageal echocardiography (TEE) showed external compression by a lung mass and an intraluminal thrombus causing SVC obstruction. Computed tomography (CT) angiography was performed, and it confirmed the TEE findings. A provisional diagnosis of lung carcinoma was made, and he underwent endovascular therapy for rapid symptomatic relief.

    DISCUSSION: This case report highlights the role of resuscitative TEE in evaluating a hypotensive patient with clinical suspicion of SVCS at the emergency department. TEE performed at the bedside could help to diagnose and demonstrate the pathology causing SVCS in this case. TEE allowed high-quality image acquisition and was able to overcome the limitation of transthoracic echocardiography (TTE). TEE should be considered as an alternative ED imaging modality in the management of SVCS.

    Matched MeSH terms: Echocardiography, Transesophageal/adverse effects
  3. Latiff HA, Samion H, Kandhavel G, Aziz BA, Alwi M
    Cardiol Young, 2001 Mar;11(2):201-4.
    PMID: 11293739
    BACKGROUND: From January, 1997, as part of an international multicentric trial, we have been closing small-to-moderate atrial septal defects within the oval fossa using the Amplatzer Septal Occluder (ASO, AGA Medical).

    METHODS: All patients with defects within the oval fossa deemed potentially suitable for transcatheter closure were investigated by transesophageal echocardiography with the aim of gaining extra information that might alter the decision to use the device to close the defect. Views were obtained in transverse and longitudinal planes, permitting measurements of the diameter of the defect, and its distance from the atrioventricular valves, coronary sinus, and pulmonary veins. Additionally, we sought to identify multiple defects, and to exclude sinus venosus defects.

    RESULTS: Of 56 patients with left-to-right shunts, 41 (73.2%) were deemed suitable for closure with the Amplatzer Septal Occluder. All underwent the procedure successfully, with no complications. This includes 5 patients with multiple small defects that were sufficiently close to the main defect to be closed with a single device. Only two of these had been detected on the transthoracic study. In the remaining 15 of 56 patients, transcatheter closure was deemed unsuitable. In 9 patients, this was due to the limitation of the size of the device available during the period of study, this representing a relative contraindication. In the remaining 6 (10.7%), transcatheter closure was not performed because multiple defects were too far apart to be closed with a single device in 3 patients, two patients were noted to have a sinus venosus defect, and another was noted to have anomalous connection of the right upper pulmonary vein to the right atrium. Excluding patients contraindicated due to the size of the defect alone, transesophageal echocardiography provided extra information in one-tenth of our patients, which altered the decision regarding management.

    CONCLUSION: Transesophageal echocardiography is indispensable in the evaluation of patients undergoing transcatheter closure of atrial septal defect.

    Matched MeSH terms: Echocardiography, Transesophageal*
  4. Osman A, Fong CP, Wahab SFA, Panebianco N, Teran F
    J Emerg Med, 2020 Sep;59(3):418-423.
    PMID: 32591302 DOI: 10.1016/j.jemermed.2020.05.003
    BACKGROUND: Although surface sonography has become an essential diagnostic tool in the evaluation of trauma patients, important limitations of this modality include the evaluation of retroperitoneal hemorrhage and mediastinal pathology, such as blunt traumatic aortic injuries (BTAI). As in other emergency applications where surface sonography can't provide the information needed, focused transesophageal echocardiography (TEE) may represent a valuable diagnostic tool in the evaluation of hemodynamically unstable trauma patients with suspected thoracic pathology such as BTAI.

    CASE SERIES: We present a series of five cases that illustrate the diagnostic value of emergency physician-performed resuscitative TEE in the diagnosis of BTAI in patients presenting with blunt thoracic trauma. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: As the use of point-of-care TEE during resuscitation continues to expand in emergency medicine, the evaluation of patients with BTAI represents a novel application where this emerging modality can allow early diagnosis of these injuries in hemodynamically unstable patients.

    Matched MeSH terms: Echocardiography, Transesophageal
  5. Zainudin AR, Tiong KG, Mokhtar SA
    Ann Pediatr Cardiol, 2012 Jan;5(1):92-4.
    PMID: 22529613 DOI: 10.4103/0974-2069.93725
    Cor triatriatum dexter is a rare congenital heart anomaly where the right atrium is divided into two chambers by a membrane. We report a boy who had persistent mild cyanosis and diagnosed to have cor triatriatum dexter with secundum atrial septal defect by transoesophageal echocardiography. Interestingly, he had persistent mild cyanosis despite insignificant obstruction to the right ventricular inflow and normal pulmonary artery pressure. The pathophysiology, approach to the diagnosis, and mode of treatment are also discussed.
    Matched MeSH terms: Echocardiography, Transesophageal
  6. Pahl C, Ebelt H, Sayahkarajy M, Supriyanto E, Soesanto A
    J Med Syst, 2017 Aug 15;41(10):148.
    PMID: 28812247 DOI: 10.1007/s10916-017-0786-4
    This paper proposes a robotic Transesophageal Echocardiography (TOE) system concept for Catheterization Laboratories. Cardiovascular disease causes one third of all global mortality. TOE is utilized to assess cardiovascular structures and monitor cardiac function during diagnostic procedures and catheter-based structural interventions. However, the operation of TOE underlies various conditions that may cause a negative impact on performance, the health of the cardiac sonographer and patient safety. These factors have been conflated and evince the potential of robot-assisted TOE. Hence, a careful integration of clinical experience and Systems Engineering methods was used to develop a concept and physical model for TOE manipulation. The motion of different actuators of the fabricated motorized system has been tested. It is concluded that the developed medical system, counteracting conflated disadvantages, represents a progressive approach for cardiac healthcare.
    Matched MeSH terms: Echocardiography, Transesophageal
  7. Lauridsen TK, Selton-Suty C, Tong S, Afonso L, Cecchi E, Park L, et al.
    Int J Cardiovasc Imaging, 2016 Jul;32(7):1041-51.
    PMID: 27100526 DOI: 10.1007/s10554-016-0873-5
    Echocardiography is essential for the diagnosis and management of infective endocarditis (IE). However, the reproducibility for the echocardiographic assessment of variables relevant to IE is unknown. Objectives of this study were: (1) To define the reproducibility for IE echocardiographic variables and (2) to describe a methodology for assessing quality in an observational cohort containing site-interpreted data. IE reproducibility was assessed on a subset of echocardiograms from subjects enrolled in the International Collaboration on Endocarditis registry. Specific echocardiographic case report forms were used. Intra-observer agreement was assessed from six site readers on ten randomly selected echocardiograms. Inter-observer agreement between sites and an echocardiography core laboratory was assessed on a separate random sample of 110 echocardiograms. Agreement was determined using intraclass correlation (ICC), coverage probability (CP), and limits of agreement for continuous variables and kappa statistics (κweighted) and CP for categorical variables. Intra-observer agreement for LVEF was excellent [ICC = 0.93 ± 0.1 and all pairwise differences for LVEF (CP) were within 10 %]. For IE categorical echocardiographic variables, intra-observer agreement was best for aortic abscess (κweighted = 1.0, CP = 1.0 for all readers). Highest inter-observer agreement for IE categorical echocardiographic variables was obtained for vegetation location (κweighted = 0.95; 95 % CI 0.92-0.99) and lowest agreement was found for vegetation mobility (κweighted = 0.69; 95 % CI 0.62-0.86). Moderate to excellent intra- and inter-observer agreement is observed for echocardiographic variables in the diagnostic assessment of IE. A pragmatic approach for determining echocardiographic data reproducibility in a large, multicentre, site interpreted observational cohort is feasible.
    Matched MeSH terms: Echocardiography, Transesophageal*
  8. Rosly NB, Loo GH, Shuhaili MAB, Rajan R, Ritza Kosai N
    Int J Surg Case Rep, 2019;61:161-164.
    PMID: 31374465 DOI: 10.1016/j.ijscr.2019.07.039
    INTRODUCTION: Transoesophageal echocardiography (TOE) is a widely used intraoperative diagnostic tool in cardiac patients, and it is considered as a safe and non-invasive procedure. However, it has its known complications, which is estimated to be 0.18% with mortality reported as 0.0098%. Complications of TOE include odynophagia, upper gastrointestinal haemorrhage, endotracheal tube malpositioning and dental injury. One of the rarer complications includes oesophageal perforation, whose incidence is reported to be 0.01%.

    CASE PRESENTATION: We present a case of a 61-year-old lady with mitral valve prolapse (MVP) who underwent TOE with subsequent presentation of odynophagia with left neck swelling. An upper endoscopy examination was inconclusive; however, a contrasted computed tomography of the neck showed evidence of cervical oesophageal perforation. She was managed conservatively and discharged well.

    DISCUSSION: The trauma caused by TOE probe insertion and manipulation accounts for most of the upper gastrointestinal complications. Mortality of patients associated with oesophageal perforation can be up to 20% and doubled if the treatment is delayed for more than 24 h. Mechanism of injury from TOE probe is likely multifactorial. Predisposing factors that increase the risk of tissue disruption include the presence of unknown structural pathology. Imaging studies and an upper endoscopy examination may aid in the diagnosis of oesophageal perforation.

    CONCLUSION: A high index of suspicion, coupled with a tailored, multidisciplinary approach, is essential to achieve the best possible outcome. Conservative management may be worthwhile in a stable patient despite delayed presentation. Although TOE is considered a safe procedure, physicians should be made aware of such a dreaded complication.

    Matched MeSH terms: Echocardiography, Transesophageal
  9. Monaco F, Di Prima AL, Kim JH, Plamondon MJ, Yavorovskiy A, Likhvantsev V, et al.
    J Cardiothorac Vasc Anesth, 2020 Jun;34(6):1622-1635.
    PMID: 32276758 DOI: 10.1053/j.jvca.2020.02.038
    SEPARATION from cardiopulmonary bypass (CPB) after cardiac surgery is a progressive transition from full mechanical circulatory and respiratory support to spontaneous mechanical activity of the lungs and heart. During the separation phase, measurements of cardiac performance with transesophageal echocardiography (TEE) provide the rationale behind the diagnostic and therapeutic decision-making process. In many cases, it is possible to predict a complex separation from CPB, such as when there is known preoperative left or right ventricular dysfunction, bleeding, hypovolemia, vasoplegia, pulmonary hypertension, or owing to technical complications related to the surgery. Prompt diagnosis and therapeutic decisions regarding mechanical or pharmacologic support have to be made within a few minutes. In fact, a complex separation from CPB if not adequately treated leads to a poor outcome in the vast majority of cases. Unfortunately, no specific criteria defining complex separation from CPB and no management guidelines for these patients currently exist. Taking into account the above considerations, the aim of the present review is to describe the most common scenarios associated with a complex CPB separation and to suggest strategies, pharmacologic agents, and para-corporeal mechanical devices that can be adopted to manage patients with complex separation from CPB. The routine management strategies of complex CPB separation of 17 large cardiac centers from 14 countries in 5 continents will also be described.
    Matched MeSH terms: Echocardiography, Transesophageal
  10. Kunwar MA, Muhammad I, Khan MN, Sumreen B, Soomro NA, Naseeb K, et al.
    Cureus, 2020 Jun 03;12(6):e8419.
    PMID: 32642335 DOI: 10.7759/cureus.8419
    Background Acute myocardial infarction (MI) is the leading cause of worldwide cardiac morbidities and mortalities. Mitral regurgitation (MR) is a common complication of MI. The severity of ischemic MR (IMR) can range widely, both clinically and hemodynamically. Mitral valve (MV) repair by lifting annuloplasty is a surgical procedure used to correct the pathology of IMR. The immediate outcomes of this technique have not yet been determined. The present study, therefore, evaluated the immediate results of MV annuloplasty performed to complement MV repair in patients with IMR. Methodology All adult patients with IMR who underwent lifting posterior mitral annuloplasty (LPMA) plus concomitant coronary artery bypass grafting (CABG) were included. Immediate outcomes were evaluated by transesophageal color Doppler echocardiography. The frequency of successful outcomes was compared in patients with different baseline characteristics. Results Posterior mitral annuloplasty was successful in 93.1% of patients, including in 92.8% of men and 94.1% of women. The percentages of successful immediate outcomes differed significantly in patients with and without diabetes and hypertension, and in patients with two- and three-vessel disease. Conclusion LPMA resulted in a high percentage of successful immediate outcomes in patients with IMR. Further studies should compare rates of immediate, intermediate, and late outcomes of this technique.
    Matched MeSH terms: Echocardiography, Transesophageal
  11. Leong MC, Latiff HA, Hew CC, Mazlan SL, Osman H
    Echocardiography, 2013 Feb;30(2):E33-5.
    PMID: 23134298 DOI: 10.1111/echo.12044
    An inverted left atrial appendage is a rare phenomenon post cardiac surgery. The lesion presents as an additional mass in the left atrium, which would trigger unnecessary concerns and frequently, a battery of tests. The lesion can be easily diagnosed using echocardiography. We report a case of inverted left atrial appendage in a patient post repair of common arterial trunk. Echocardiographic pictures and features which help to identify this lesion as well as to differentiate it from other possible left atrial mass are described. This article aimed to improve the awareness of sonographers toward this rare but possible post operative lesion.
    Matched MeSH terms: Echocardiography, Transesophageal/methods*
  12. Jung HJ, Kwon WK, Lee SJ, Mohamed N, Shin BM, Lee J, et al.
    BMC Anesthesiol, 2016 10 04;16(1):83.
    PMID: 27716083
    BACKGROUND: This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography.

    CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.

    CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.

    Matched MeSH terms: Echocardiography, Transesophageal/methods*
  13. Tan JH, Ng ZQ, Vendargon S
    BMJ Case Rep, 2018 Apr 17;2018.
    PMID: 29666108 DOI: 10.1136/bcr-2018-225271
    Matched MeSH terms: Echocardiography, Transesophageal/methods
  14. Wong MH, Chee KH, Azman W
    Singapore Med J, 2009 Oct;50(10):e362-4.
    PMID: 19907876
    A 40-year-old Malay woman presented with increasing lethargy, palpitation and shortness of breath, 17 years after a mitral and aortic valve replacement. A Starr-Edwards prosthetic valve replaced the mitral valve, and a Bjork-Shiley prosthetic valve replaced the aortic valve. Biochemical parameters demonstrated intravascular haemolysis, as evidenced by haemoglobin 7.8 g/dL, reticulocyte count 8.4%, lactate dehydrogenase 2,057 IU/L and low haptoglobulin levels (less than 6 mg/dL). Transoesophageal echocardiography revealed a paravalvular leakage over the mitral valve. The haemoglobin levels remained persistently low despite frequent blood transfusions. She successfully underwent a second mitral valve replacement. Her anaemia resolved subsequently.
    Matched MeSH terms: Echocardiography, Transesophageal/methods
  15. Tamin SS, Dillon J, Aizan K, Kadiman S, Latiff HA
    Echocardiography, 2012 Feb;29(2):E34-8.
    PMID: 22044509 DOI: 10.1111/j.1540-8175.2011.01543.x
    This case report describes a 20-year-old woman with Turner's syndrome who presented with reduced effort tolerance limited by dyspnea. She had previously been on pediatric cardiology follow-up for congenital subvalvular aortic stenosis first diagnosed at age 7. Unfortunately she defaulted after two visits before any intervention could be done. Transthoracic echocardiography demonstrated severe aortic incompetence (AI) with a membrane-like structure in the left ventricular outflow tract (LVOT). The mean pressure gradient across the LVOT on continuous wave Doppler was 41 mmHg. The membranous interventricular septum appeared aneurysmal and it was observed that the "subaortic membrane" had a connection to the anterolateral papillary muscle via a strand of chordal tissue. Further images were captured using two-dimensional and three-dimensional transthoracic and transesophageal echocardiography (iE33, Philips Medical Systems, Andover, MA, USA). After a review of the literature it was concluded that this appeared to be an accessory mitral valve (AMV) leaflet causing LVOT obstruction associated with AI. AMV tissue is a rare congenital malformation causing LVOT obstruction. Because it is so unusual, it may not be immediately recognizable even in a high volume echocardiography laboratory. The clue which helped with the diagnosis was the strand of chordal tissue which connected the mass to the papillary muscle. This anomaly is often associated with LVOT obstruction.
    Matched MeSH terms: Echocardiography, Transesophageal/methods
  16. Piaw CS, Kiam OT, Rapaee A, Khoon LC, Bang LH, Ling CW, et al.
    Cardiovasc Intervent Radiol, 2006 Mar-Apr;29(2):230-4.
    PMID: 16252078
    Transesophageal echocardiography (TEE) is a trusted method of sizing atrial septal defect (ASD) prior to percutaneous closure but is invasive, uncomfortable, and may carry a small risk of morbidity and mortality. Magnetic resonance imaging (MRI) may be useful non-invasive alternative in such patients who refuse or are unable to tolerate TEE and may provide additional information on the shape of the A0SD.
    Matched MeSH terms: Echocardiography, Transesophageal
  17. Adi O, Ahmad AH, Fong CP, Ranga A, Panebianco N
    Ultrasound J, 2021 Apr 15;13(1):22.
    PMID: 33856577 DOI: 10.1186/s13089-021-00225-7
    BACKGROUND: Pericardial effusion is a known complication of post-open cardiac surgery which can progress to life-threatening cardiac tamponade. Classical signs of tamponade such as hypotension and pulsus paradoxus are often absent. Diagnosing acute cardiac tamponade with transthoracic echocardiography (TTE) can be challenging in post-cardiac surgical patients due to distorted anatomy and limited scanning windows by the presence of surgical dressings or scar. Additionally, this patient population is more likely to have a loculated pericardial effusion, or an effusion that is isoechoic in appearance secondary to clotted blood. These findings can be challenging to visualize with traditional TTE. Missed diagnosis of cardiac tamponade due to loculated pericardial clot can result in delayed diagnosis and clinical management.

    CASE PRESENTATION: We report a case series that illustrates the diagnostic challenge and value of resuscitative transesophageal echocardiography (TEE) in the emergency department (ED) for the diagnosis of cardiac tamponade due to posterior loculated pericardial clot in post-surgical coronary artery bypass graft (CABG) patients.

    CONCLUSIONS: Cardiac tamponade due to loculated posterior pericardial clot post-CABG requires prompt diagnosis and appropriate management to avoid the potential for hemodynamic instability. Transesophageal echocardiography allows a rapid diagnosis, early appropriate referral and an opportunity to institute appropriate therapeutic measures.

    Matched MeSH terms: Echocardiography, Transesophageal
  18. Tai ML, Tan EC, Ang CC, Liam CK
    Singapore Med J, 2016 Sep;57(9):524-5.
    PMID: 27663211 DOI: 10.11622/smedj.2016157
    Matched MeSH terms: Echocardiography, Transesophageal
  19. Lauridsen TK, Park L, Tong SY, Selton-Suty C, Peterson G, Cecchi E, et al.
    Circ Cardiovasc Imaging, 2015 Jul;8(7):e003397.
    PMID: 26162783 DOI: 10.1161/CIRCIMAGING.114.003397
    Staphylococcus aureus left-sided native valve infective endocarditis (LNVIE) has higher complication and mortality rates compared with endocarditis from other pathogens. Whether echocardiographic variables can predict prognosis in S aureus LNVIE is unknown.
    Matched MeSH terms: Echocardiography, Transesophageal*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links