Displaying all 3 publications

Abstract:
Sort:
  1. Ahmad M, Roy RA, Kamarudin AG, Safar M
    Int Endod J, 1993 Mar;26(2):120-4.
    PMID: 8330934
    The pattern of oscillation of a Piezon-Master 400 ultrasonic file driven by a piezoelectric transducer was studied in air and on water. In addition, the displacement amplitudes of the files were measured. The findings were compared with those observed with the Cavi-Endo unit reported in another study (Ahmad 1969). It was observed that the file vibrated such that a standing wave was formed on the file and it exhibited points of maximum deflection (antinode) and points of minimum deflection (node) with the largest deflection occurring at the apical end. This pattern of oscillation was similar to that exhibited by the Cavi-Endo file which employed a magnetostrictive transducer. However, the displacement amplitudes were very much higher than those exhibited by the Cavi-Endo. It is considered that the 120 degrees angle of the file holder inherent in the Piezon-Master 400 unit and the more effective power transmission with the piezoelectric transducer may have contributed to the large amplitudes.
    Matched MeSH terms: Dental Cavity Preparation/instrumentation*
  2. Ahmad M
    Endod Dent Traumatol, 1990 Jun;6(3):104-8.
    PMID: 2079012
    Matched MeSH terms: Dental Cavity Preparation/instrumentation*
  3. Ahmad M
    Endod Dent Traumatol, 1991 Apr;7(2):55-8.
    PMID: 1782894
    The efficacy of two ultrasonic units in shaping curved canals in teeth were compared. Twenty teeth were instrumented using the Cavi-Endo unit at a power setting 1 using the technique recommended by the manufacturer. Another group of 20 teeth received similar treatment but were instrumented with the Enac unit. The time taken to instrument each canal was recorded. The pre- and post-instrumented radiographs of the teeth of x 10 magnification were taken using a microfocal technique. The radiographs were subjected to a subtraction technique to result in composite images of the pre- and post-instrumented shapes. The canal shape and the incidence of elbows were evaluated using various measurements taken from the radiographs. The manner the dentine was removed was similar in both groups. All canals exhibited unequal removal along the canal with more dentine being removed at the coronal end. The Enac group exhibited a higher incidence of elbows which occurred further apically than those in the Cavi-Endo group. There was no significant difference between groups in the following: time of instrumentation, amount of apical and coronal canal enlargement, apical deviation and change in width at the elbow. These findings were no different from those of another study using simulated canals.
    Matched MeSH terms: Dental Cavity Preparation/instrumentation*