Displaying all 16 publications

Abstract:
Sort:
  1. Ahmad M, Roy RA, Kamarudin AG, Safar M
    Int Endod J, 1993 Mar;26(2):120-4.
    PMID: 8330934
    The pattern of oscillation of a Piezon-Master 400 ultrasonic file driven by a piezoelectric transducer was studied in air and on water. In addition, the displacement amplitudes of the files were measured. The findings were compared with those observed with the Cavi-Endo unit reported in another study (Ahmad 1969). It was observed that the file vibrated such that a standing wave was formed on the file and it exhibited points of maximum deflection (antinode) and points of minimum deflection (node) with the largest deflection occurring at the apical end. This pattern of oscillation was similar to that exhibited by the Cavi-Endo file which employed a magnetostrictive transducer. However, the displacement amplitudes were very much higher than those exhibited by the Cavi-Endo. It is considered that the 120 degrees angle of the file holder inherent in the Piezon-Master 400 unit and the more effective power transmission with the piezoelectric transducer may have contributed to the large amplitudes.
    Matched MeSH terms: Dental Cavity Preparation/instrumentation*
  2. Tay WM
    Dent J Malaysia Singapore, 1968 Feb;8(1):24-8.
    PMID: 5248555
    Matched MeSH terms: Dental Cavity Preparation
  3. Husein, A.
    MyJurnal
    Lasers were introduced into the field of clinical dentistry with the hope of overcoming some of the drawbacks posed by the conventional methods of dental procedures. Since its first experiment for dental application in the 1960s, the use of laser has increased rapidly in the last couple of decades. At present, wide varieties of procedures are carried out using lasers. The aim of this review is to describe the application of lasers in dental hard tissue procedures. Lasers are found to be effective in cavity preparation, caries removal, restoration removal, etching, and treatment of dentinal sensitivity, caries prevention and bleaching. Based on development in adhesive dentistry and the propagation of minimum intervention principles, lasers may revolutionize cavity design and preparation.
    Matched MeSH terms: Dental Cavity Preparation
  4. Liew, Amy Kia Cheen, Hazem Dabbour, Dalia Abdullah
    MyJurnal
    Demonstration of the access cavity preparation procedures to dental students is
    challenging due to the limited operating field and detailed nature of the procedures. It is especially
    difficult to visualize how instruments are functioning inside the pulp space. The aim of this study
    was to develop and compare two different views of video demonstration in teaching access cavity
    preparation. (Copied from article).
    Matched MeSH terms: Dental Cavity Preparation
  5. Ahmad M
    Endod Dent Traumatol, 1990 Jun;6(3):104-8.
    PMID: 2079012
    Matched MeSH terms: Dental Cavity Preparation/instrumentation*
  6. Ballester B, Giraud T, Ahmed HMA, Nabhan MS, Bukiet F, Guivarc'h M
    Clin Oral Investig, 2021 Nov;25(11):6027-6044.
    PMID: 34623506 DOI: 10.1007/s00784-021-04080-7
    OBJECTIVES: To assess related studies and discuss the clinical implications of endodontic access cavity (AC) designs.

    MATERIALS AND METHODS: A systematic review of studies comparing the fracture resistance and/or endodontic outcomes between different AC designs was conducted in two electronic search databases (PubMed and Web of Science) following the PRISMA guidelines. Study selection, data extraction, and quality assessment were performed. Meta-analyses were undertaken for fracture resistance and root canal detection, with the level of significance set at 0.05 (P = 0.05).

    RESULTS: A total of 33 articles were included in this systematic review. The global evaluation of the risk of bias in the included studies was assessed as moderate, and the level of evidence was rated as low. Four types of AC designs were categorized: traditional (TradAC), conservative (ConsAC), ultraconservative (UltraAC), and truss (TrussAC). Their impact on fracture resistance, cleaning/disinfection, procedural errors, root canal detection, treatment time, apical debris extrusion, and root canal filling was discussed. Meta-analysis showed that compared to TradAC, (i) there is a significant higher fracture resistance of teeth with ConsAC, TrussAC, or ConsAC/TrussAC when all marginal ridges are preserved (P  0.05), and (iii) there is a significantly higher risk of undetected canals with ConsAC if not assisted by dental operating microscope and ultrasonic troughing (P 

    Matched MeSH terms: Dental Cavity Preparation*
  7. Alani, A.H., Abdul Aziz Abdul Razak
    Ann Dent, 1996;3(1):-.
    MyJurnal
    The canine teeth of the mature ferret have closed apices. They are easily accessible for operating purposes and are sufficiently large, allowing conventional cavity preparation techniques to be prepared using ordinary dental instruments. Handling of the ferret is relatively easy since it becomes quite tame after a period of time. The body weight in male is greater and the teeth larger than those of the female. The cost of purchase and maintenance of the ferret is also inexpensive. For all these reasons, the ferret male is animal of choice in dental experiments.
    Matched MeSH terms: Dental Cavity Preparation
  8. Harsha MS, Praffulla M, Babu MR, Leneena G, Krishna TS, Divya G
    J Clin Diagn Res, 2017 May;11(5):ZC45-ZC48.
    PMID: 28658906 DOI: 10.7860/JCDR/2017/25305.9856
    INTRODUCTION: Cavity preparations of posterior teeth have been frequently associated with decreased fracture strength of the teeth. Choosing the correct indirect restoration and the cavity design when restoring the posterior teeth i.e., premolars was difficult as it involves aesthetic, biomechanical and anatomical considerations.

    AIM: To evaluate the fracture resistance and failure pattern of three different cavity designs restored with monolithic zirconia.

    MATERIALS AND METHODS: Human maxillary premolars atraumatically extracted for orthodontic reasons were chosen. A total of 40 teeth were selected and divided into four groups (n=10). Group I-Sound teeth (control with no preparation). Group II-MOD Inlay, Group III-Partial Onlay, Group IV-Complete Onlay. Restorations were fabricated with monolithic partially sintered zirconia CAD (SAGEMAX- NexxZr). All the 30 samples were cemented using Multilink Automix (Ivoclar) and subjected to fracture resistance testing using Universal Testing Machine (UTM) (Instron) with a steel ball of 3.5 mm diameter at crosshead speed of 0.5 mm/minute. Stereomicroscope was used to evaluate the modes of failure of the fractured specimen. Fracture resistance was tested using parametric one way ANOVA test, unpaired t-test and Tukey test. Fracture patterns were assessed using non-parametric Chi-square test.

    RESULTS: Group IV (Complete Onlay) presented highest fracture resistance and showed statistical significant difference. Group II (MOD Inlay) and Group III (Partial Onlay) showed significantly lower values than the Group I (Sound teeth). However, Groups I, II and III presented no significant difference from each other. Coming to the modes of failure, Group II (MOD Inlay) and Group III (Partial Onlay) presented mixed type of failures; Group IV (Complete Onlay) demonstrated 70% Type I failures.

    CONCLUSION: Of the three cavity designs evaluated, Complete Onlay had shown a significant increase in the fracture resistance than the Sound teeth.

    Matched MeSH terms: Dental Cavity Preparation
  9. Chee HT, Wan Bakar WZ, Ghani ZA, Amaechi BT
    Dent Res J (Isfahan), 2018 6 21;15(3):215-219.
    PMID: 29922341
    Background: Composite resin (CR) currently is one of the most commonly used material in restoring noncarious cervical lesions (NCCL) due to its strength and esthetics color but has microleakage problem. The aim of this study is to compare in vitro the microleakage depth between CR and porcelain in restoring NCCL.

    Materials and Methods: This an in vitro study was done by preparing cavities on the buccocervical surface of 62 extracted premolar teeth which randomly assigned to two groups (n = 31) where Group 1 was restored with nanocomposite and Group 2 was cemented with porcelain cervical inlays. They were then subjected to thermocycling before immersion in 2% methylene blue dye for 24 h. Dye penetration depths were measured using Leica imaging system For statistical analysis, independent t-test was used to analyze the results (P < 0.05).

    Results: Porcelain cervical inlay restorations demonstrated statistically lesser microleakage depth for the cervical margins (P = 0.018) when compared to CR. Deeper microleakage depth at the cervical compared to coronal margins of CR (P = 0.006) but no significant difference of both margins for porcelain cervical inlays (P = 0.600).

    Conclusion: Porcelain cervical inlays show lesser microleakage than CR which could be alternative treatment option in restoring NCCL with better marginal seal and esthetics.

    Matched MeSH terms: Dental Cavity Preparation
  10. Ahmad M
    Endod Dent Traumatol, 1991 Apr;7(2):55-8.
    PMID: 1782894
    The efficacy of two ultrasonic units in shaping curved canals in teeth were compared. Twenty teeth were instrumented using the Cavi-Endo unit at a power setting 1 using the technique recommended by the manufacturer. Another group of 20 teeth received similar treatment but were instrumented with the Enac unit. The time taken to instrument each canal was recorded. The pre- and post-instrumented radiographs of the teeth of x 10 magnification were taken using a microfocal technique. The radiographs were subjected to a subtraction technique to result in composite images of the pre- and post-instrumented shapes. The canal shape and the incidence of elbows were evaluated using various measurements taken from the radiographs. The manner the dentine was removed was similar in both groups. All canals exhibited unequal removal along the canal with more dentine being removed at the coronal end. The Enac group exhibited a higher incidence of elbows which occurred further apically than those in the Cavi-Endo group. There was no significant difference between groups in the following: time of instrumentation, amount of apical and coronal canal enlargement, apical deviation and change in width at the elbow. These findings were no different from those of another study using simulated canals.
    Matched MeSH terms: Dental Cavity Preparation/instrumentation*
  11. Jesmin F, Kamarudin A, Baharin F, Ahmad WMABW, Mohammed M, Marya A, et al.
    Biomed Res Int, 2021;2021:8424206.
    PMID: 34977246 DOI: 10.1155/2021/8424206
    Introduction: Hall's technique preformed metal crown (HTPMC) has been used widely by pediatric dentists in developed countries as a new approach for managing decayed primary molars without local anesthesia, caries removal, and tooth preparation. Currently, inadequate information is available regarding the implementation of this technique (HTPMC) in Malaysia. This study is aimed at evaluating the implementation of HTPMC by Malaysia's pediatric dentists and identify the co-occurrence frequencies of the HTPMC implementation with the respondents' demographic profile.

    Materials and Methods: A cross-sectional questionnaire-based research was conducted among 65 pediatric dentists in Malaysia. Online questionnaires were distributed to the pediatric dentists employed at public hospitals (MOH) and universities in Malaysia.

    Result: It was found that over half of the respondents (65.6%) employed HTPMC. The analysis of the co-occurrence network frequency revealed that a high frequency of female pediatric dentists who were within the age group of 31-40 years old had fulfilled their postgraduation overseas and was employed in the university mainly applied HTPMC.

    Conclusion: The application of HTPMC among respondent pediatric dentists in Malaysia was high. However, most respondents considered HTPMC a treatment option only to manage carious primary molar rather than a treatment of choice.

    Matched MeSH terms: Dental Cavity Preparation/methods*; Dental Cavity Preparation/statistics & numerical data*
  12. Sidhu P, Sultan OS, Math SY, Malik NA, Wilson NHF, Lynch CD, et al.
    J Dent, 2021 07;110:103683.
    PMID: 33957189 DOI: 10.1016/j.jdent.2021.103683
    OBJECTIVE: To investigate the current and future teaching of posterior composite restorations in undergraduate curricula in Malaysian dental schools.

    METHODS: A 24-item validated questionnaire including closed and open questions on the teaching of posterior composites was emailed to faculty members in all 13 Dental Schools in Malaysia. Responses were compiled on Excel and analysed.

    RESULTS: All 13 dental schools responded to the survey yielding a 100 % response. All schools indicated the use of posterior composites for 2- and 3-surface cavities in premolars and molars. The didactic teaching time devoted to composites was greater than for amalgam (38 h vs 29 h). Clinically, most posterior restorations placed by students were composites (average 74.1 %, range 10 %-100 %); the remaining 25.9 % were amalgams (range, 0 %-50 %). Slot-type cavities were the preparation techniques most commonly taught (n = 11,84.6 %). The use of rubber dam for moisture control was mandatory in most schools (n = 11, 84.6 %). History of adverse reaction to composites was found to be the most common contraindication to composite placement. The phase down of teaching and use of amalgam in Malaysia is expected to occur within the next six years.

    CONCLUSION: The trend to increase the teaching of posterior composites reported for other countries is confirmed by the findings from Malaysian dental schools. Notwithstanding this trend, the use of amalgam is still taught, and future studies are required to investigate the implications of the phase down of amalgam in favour of posterior composites.

    CLINICAL SIGNIFICANCE: Notwithstanding the increase in the teaching of posterior composites there is a pressing need to update and refine clinical guidelines for the teaching of posterior composites globally.

    Matched MeSH terms: Dental Cavity Preparation
  13. Abdul Aziz, A., Abu Kasim, N.H., Ramasindarum, C., Mohamad Yusof, M.Y.P., Paiizi, M., Ahmad, R.
    Ann Dent, 2011;18(1):1-7.
    MyJurnal
    The aim of this study was to assess the wear of tungsten carbide burs and round rotary diamond instruments through measurements of rake angle and visual observations respectively under a field emission scanning electron microscope. Sixty short and long head pear-shaped tungsten carbide burs and 18 round rotary diamond instruments that had been used to complete < 5, > 5 and > 10 cavity preparations (n=10/group) were selected from the 3rd and 4th year dental students, Faculty of Dentistry, University of Malaya. There were two control groups consisting of long and short tungsten carbide burs of ten each. Two-way ANOVA was used to analyse the rake angle data. The data from the two control groups were collectively analysed following multiple paired t-test (p>.05) which showed no significant difference between the two types of tungsten carbide bur (short and long head). The mean rake angle of the control group was significantly higher (p < .05) compared to the < 5, > 5 and > 10 cavity preparation groups. The rake angle of the > 10 cavity preparation group was significantly lower than the other two test groups (p < .05). Round rotary diamond instruments in the < 5 cavity preparation group showed intact diamond particles with distinct cutting facets comparable to the control group. However, diamonds instruments in the > 5 and > 10 cavity preparation groups showed blunt diamond particles. In conclusion, wear of tungsten carbide burs and round rotary diamond instruments were evident after repeated use. Wear was more pronounced when instruments were used to prepare more than ten cavities.
    Matched MeSH terms: Dental Cavity Preparation
  14. Purmal K, Nambiar P
    J Vet Dent, 2009;26(1):36-9.
    PMID: 19476086
    Matched MeSH terms: Dental Cavity Preparation/veterinary
  15. Mustafa AA, Matinlinna JP, Saidin S, Kadir MR
    J Prosthet Dent, 2014 Dec;112(6):1498-506.
    PMID: 24993375 DOI: 10.1016/j.prosdent.2014.05.011
    STATEMENT OF PROBLEM: The inconsistency of dentin bonding affects retention and microleakage.

    PURPOSE: The purpose of this laboratory and finite element analysis study was to investigate the effects on the formation of a hybrid layer of an experimental silane coupling agent containing primer solutions composed of different percentages of hydroxyethyl methacrylate.

    MATERIAL AND METHODS: A total of 125 sound human premolars were restored in vitro. Simple class I cavities were formed on each tooth, followed by the application of different compositions of experimental silane primers (0%, 5%, 25%, and 50% of hydroxyethyl methacrylate), bonding agents, and dental composite resins. Bond strength tests and scanning electron microscopy analyses were performed. The laboratory experimental results were validated with finite element analysis to determine the pattern of stress distribution. Simulations were conducted by placing the restorative composite resin in a premolar tooth by imitating simple class I cavities. The laboratory and finite element analysis data were significantly different from each other, as determined by 1-way ANOVA. A post hoc analysis was conducted on the bond strength data to further clarify the effects of silane primers.

    RESULTS: The strongest bond of hybrid layer (16.96 MPa) was found in the primer with 25% hydroxyethyl methacrylate, suggesting a barely visible hybrid layer barrier. The control specimens without the application of the primer and the primer specimens with no hydroxyethyl methacrylate exhibited the lowest strength values (8.30 MPa and 11.78 MPa) with intermittent and low visibility of the hybrid layer. These results were supported by finite element analysis that suggested an evenly distributed stress on the model with 25% hydroxyethyl methacrylate.

    CONCLUSIONS: Different compositions of experimental silane primers affected the formation of the hybrid layer and its resulting bond strength.

    Matched MeSH terms: Dental Cavity Preparation/classification
  16. Razak AA, Harrison A
    J Prosthet Dent, 1997 Apr;77(4):353-8.
    PMID: 9104710
    Dimensional accuracy of a composite inlay restoration is important to ensure an accurate fit and to minimize cementation stresses.
    Matched MeSH terms: Dental Cavity Preparation
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links