Displaying all 3 publications

Abstract:
Sort:
  1. Azarisman SM, Sabruddin MZ, Rosli MA
    Int Heart J, 2011;52(1):61-3.
    PMID: 21321471
    We report a 69 year old female who presented with chest pain to the Emergency Department of the National Heart Institute Malaysia. Her history revealed that she had had 2 separate episodes of chest pain beginning in 2002, resulting in total occlusion of her mid left anterior descending artery (LAD) requiring percutaneous coronary intervention and stenting on both occasions. Cine angiogram on her current admission revealed recurrent target lesion in-stent restenosis with total occlusion of the distal LAD. Intravascular ultrasound revealed multilayered suboptimally deployed stents in the LAD. Successive drug-eluting balloon deployments resulted in sustained patency of the LAD after 1 year.
    Matched MeSH terms: Coronary Restenosis/therapy*
  2. Choo GH, Le D, Nguyen K, Phan H, Nguyen Q, Nguyen J
    Chin Med J (Engl), 2012 Oct;125(19):3565-8.
    PMID: 23044325
    Matched MeSH terms: Coronary Restenosis/therapy*
  3. Ali RM, Abdul Kader MASK, Wan Ahmad WA, Ong TK, Liew HB, Omar AF, et al.
    JACC Cardiovasc Interv, 2019 Mar 25;12(6):558-566.
    PMID: 30898253 DOI: 10.1016/j.jcin.2018.11.040
    OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB).

    BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR.

    METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 μg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 μg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis.

    RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups.

    CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).

    Matched MeSH terms: Coronary Restenosis/therapy*
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links