Displaying all 7 publications

Abstract:
Sort:
  1. Ma WT, Mahadeva S, Kunanayagam S, Poi PJ, Goh KL
    J Dig Dis, 2007 May;8(2):77-81.
    PMID: 17532819
    Colonoscopy is believed to be more complicated in elderly patients in Western countries. It is uncertain if the situation holds true among Asians. This study is to determine differences in colonoscopy performance and sedation complications between patients aged<65 years and those>or=65 years of age in an Asian population.
    Matched MeSH terms: Colonoscopy/adverse effects*
  2. Yoshida N, Fukumoto K, Hasegawa D, Inagaki Y, Inoue K, Hirose R, et al.
    J Gastroenterol Hepatol, 2021 Dec;36(12):3337-3344.
    PMID: 34260116 DOI: 10.1111/jgh.15625
    BACKGROUND AND AIM: High-grade dysplasia (HGD) and T1 lesions are accidentally resected by cold snare polypectomy (CSP) and the characteristics, and follow-up of them has not been reported. In this study, we analyzed the histopathological findings and recurrence of them.

    METHODS: This was a multicenter retrospective-cohort study. We collected HGD and T1 lesions of ≤ 10 mm resected by CSP among 15 520 patients receiving CSP from 2014 to 2019 at nine related institutions, and we extracted only cases receiving definite follow-up colonoscopy after CSP of HGD and T1 lesions. We analyzed these tumor's characteristics and therapeutic results such as R0 resection and local recurrence and risk factors of recurrence.

    RESULTS: We collected 103 patients (0.63%) and extracted 80 lesions in 74 patients receiving follow-up colonoscopy for CSP scar. Mean age was 68.4 ± 12.0, and male rate was 68.9% (51/80). The mean tumor size (mm) was 6.6 ± 2.5, and the rate of polypoid morphology and rectum location was 77.5% and 25.0%. The rate of magnified observation was 53.8%. The rates of en bloc resection and R0 resection were 92.5% and 37.5%. The local recurrence rate was 6.3% (5/80, median follow-up period: 24.0 months). The recurrence developed within 3 months after CSP for four out of five recurrent cases. Comparing five recurrent lesions to 75 non-recurrent lesions, a positive horizontal margin was a significant risk factor (60.0% vs 10.7%, P 

    Matched MeSH terms: Colonoscopy/adverse effects
  3. Chan WK, Azmi N, Mahadeva S, Goh KL
    World J Gastroenterol, 2014 Oct 21;20(39):14488-94.
    PMID: 25339836 DOI: 10.3748/wjg.v20.i39.14488
    To compare same-day whole-dose vs split-dose of 2-litre polyethylene glycol electrolyte lavage solution (PEG-ELS) plus bisacodyl for colon cleansing for morning colonoscopy.
    Matched MeSH terms: Colonoscopy/adverse effects
  4. Chan WK, Roslani AC, Law CW, Goh KL, Mahadeva S
    J Dig Dis, 2013 Dec;14(12):670-5.
    PMID: 23981291 DOI: 10.1111/1751-2980.12097
    To compare the outcomes and costs of endoluminal clipping and surgery in the management of iatrogenic colonic perforation.
    Matched MeSH terms: Colonoscopy/adverse effects*
  5. Ma WT, Mahadeva S, Quek KF, Goh KL
    Med J Malaysia, 2007 Oct;62(4):313-8.
    PMID: 18551936 MyJurnal
    Tolerance to colonoscopy varies between populations and data from the South East Asian region is lacking. We aimed to determine tolerance and safety with to colonoscopy; conscious sedation and identify risk factors for complications in Malaysian adults. Consecutive outpatients undergoing colonoscopy were enrolled prospectively. A combination of pethidine and midazolam were used and tolerance to colonoscopy assessed three hours post-procedure using a validated scale. All patients were monitored for cardiorespiratory depression and risk factors for complications were identified. Two hundred and eight patients (mean age 57.2 +/- 14.8 years, 48% female) were enrolled. The population ethnicity consisted of 45 (21.63%) Malays, 101 (48.56%) Chinese and 56 (26.92%) Indians. Conscious sedation was achieved with 5.0 +/- 1.1 mg of midazolam and 43.3 +/- 14.0 mg of pethidine. Thirty (14.4%) patients tolerated the procedure poorly and independent predictors included female gender (OR 2.93, 95% CI = 1.22 to 7.01) and a prolonged duration of procedure (OR 2.85, 95% CI = 1.08 to 7.48). Hypotension occurred in 13 (6.25%) patients, with age > 65 years as the only risk factor (OR 13.17, 95% CI = 1.28 to 137.92). A prolonged duration was the main cause of hypoxia (OR 5.49, 95% CI = 1.54 to 19.49), which occurred in 6 (2.88%) patients. No major complications occurred during the study period. The current practice of conscious sedation is safe and tolerated well by most adults in our population. However, poor tolerance in a notable minority may have significant clinical implications.

    Study site: Division of Gastroenterology, Department of Medicine, University Malaya Medical Centre (UMMC)
    Matched MeSH terms: Colonoscopy/adverse effects*
  6. Tee HP, Corte C, Al-Ghamdi H, Prakoso E, Darke J, Chettiar R, et al.
    World J Gastroenterol, 2010 Aug 21;16(31):3905-10.
    PMID: 20712051
    AIM: To study the significance of cap-fitted colonoscopy in improving cecal intubation time and polyp detection rate.

    METHODS: This study was a prospective randomized controlled trial conducted from March 2008 to February 2009 in a tertiary referral hospital at Sydney. The primary end point was cecal intubation time and the secondary endpoint was polyp detection rate. Consecutive cases of total colonoscopy over a 1-year period were recruited. Randomization into either standard colonoscopy (SC) or cap-assisted colonoscopy (CAC) was performed after consent was obtained. For cases randomized to CAC, one of the three sizes of cap was used: D-201-15004 (with a diameter of 15.3 mm), D-201-14304 (14.6 mm) and D-201-12704 (13.0 mm). All of these caps were produced by Olympus Medical Systems, Japan. Independent predictors for faster cecal time and better polyp detection rate were also determined from this study.

    RESULTS: There were 200 cases in each group. There was no significant difference in terms of demographic characteristics between the two groups. CAC, when compared to the SC group, had no significant difference in terms of cecal intubation rate (96.0% vs 97.0%, P = 0.40) and time (9.94 +/- 7.05 min vs 10.34 +/- 6.82 min, P = 0.21), or polyp detection rate (32.8% vs 31.3%, P = 0.75). On the subgroup analysis, there was no significant difference in terms of cecal intubation time by trainees (88.1% vs 84.8%, P = 0.40), ileal intubation rate (82.5% vs 79.0%, P = 0.38) or total colonoscopy time (23.24 +/- 13.95 min vs 22.56 +/- 9.94 min, P = 0.88). On multivariate analysis, the independent determinants of faster cecal time were consultant-performed procedures (P < 0.001), male patients (P < 0.001), non-usage of hyoscine (P < 0.001) and better bowel preparation (P = 0.01). The determinants of better polyp detection rate were older age (P < 0.001), no history of previous abdominal surgery (P = 0.04), patients not having esophagogastroduodenoscopy in the same setting (P = 0.003), trainee-performed procedures (P = 0.01), usage of hyoscine (P = 0.01) and procedures performed for polyp follow-up (P = 0.01). The limitations of the study were that it was a single-center experience, no blinding was possible, and there were a large number of endoscopists.

    CONCLUSION: CAC did not significantly different from SC in term of cecal intubation time and polyp detection rate.

    Matched MeSH terms: Colonoscopy/adverse effects
  7. Lee WS, Tee CW, Koay ZL, Wong TS, Zahraq F, Foo HW, et al.
    World J Gastroenterol, 2018 Mar 07;24(9):1013-1021.
    PMID: 29531465 DOI: 10.3748/wjg.v24.i9.1013
    AIM: To study implications of measuring quality indicators on training and trainees' performance in pediatric colonoscopy in a low-volume training center.

    METHODS: We reviewed retrospectively the performance of pediatric colonoscopies in a training center in Malaysia over 5 years (January 2010-December 2015), benchmarked against five quality indicators: appropriateness of indications, bowel preparations, cecum and ileal examination rates, and complications. The European Society of Gastrointestinal Endoscopy guideline for pediatric endoscopy and North American Society for Pediatric Gastroenterology, Hepatology and Nutrition training guidelines were used as benchmarks.

    RESULTS: Median (± SD) age of 121 children [males = 74 (61.2%)] who had 177 colonoscopies was 7.0 (± 4.6) years. On average, 30 colonoscopies were performed each year (range: 19-58). Except for investigations of abdominal pain (21/177, 17%), indications for colonoscopies were appropriate in the remaining 83%. Bowel preparation was good in 87%. One patient (0.6%) with severe Crohn's disease had bowel perforation. Cecum examination and ileal intubation rate was 95% and 68.1%. Ileal intubation rate was significantly higher in diagnosing or assessing inflammatory bowel disease (IBD) than non-IBD (72.9% vs 50.0% P = 0.016). Performance of four trainees was consistent throughout the study period. Average cecum and ileal examination rate among trainees were 97% and 77%.

    CONCLUSION: Benchmarking against established guidelines helps units with a low-volume of colonoscopies to identify area for further improvement.

    Matched MeSH terms: Colonoscopy/adverse effects
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links