Displaying all 5 publications

Abstract:
Sort:
  1. Thevarajah TM, Nani N, Chew YY
    Malays J Pathol, 2008 Dec;30(2):81-6.
    PMID: 19291916 MyJurnal
    HbA1c measurement is currently routinely used to predict long term outcome of diabetes, thus playing a fundamental role in the management of diabetes. The relationship between HbA1c value and long term diabetic complications has been established by a randomised control Diabetes Control and Complications Trial (DCCT) which used high performance liquid chromatography (HPLC) as a reference method for HbA1c assay. To ensure that HbA1c results from a variety HbA1c assay methods are similar to the DCCT values, the American Diabetes Association (ADA) recommended that all laboratories should use methods certified by the National Glycohemoglobin Standardization Programme (NGSP) with interassay coefficient variation (CV) of < 5% (ideally < 3%). The International Federation of Clinical Chemistry (IFCC) working group on HbA1c standardisation has set a CV < 2.5% as a criteria for its reference laboratories.
    Matched MeSH terms: Chemistry, Clinical/instrumentation*; Chemistry, Clinical/methods; Chemistry, Clinical/standards*
  2. Lai LC
    Malays J Pathol, 2008 Dec;30(2):67-71.
    PMID: 19291914 MyJurnal
    HbA1c is used for assessing glycaemic control in patients with diabetes. It is also used for treatment goals and as a target for therapeutic intervention. The Direct Control and Complications Trial in the USA showed that HbA1c can be used to predict the risk of complications. Hence, it is important for HbA1c assays to be standardised. The National Glycohemoglobin Standardization Program (NGSP) in the USA was formed in 1996 so that HbA1c results from different laboratories would be comparable to those reported in the DCCT study. There were also HbA1c standardisation programmes in Sweden and Japan. These three standardisation programmes are, in fact, direct comparison methods (DCMs), and yield different HbA1c results. In 1994, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) established a Working Group on Standardisation of HbA1c. This working group has developed a global HbA1c reference system with very much improved intra-assay and inter-assay coefficients of variation. Recommendations have been made to report HbA1c results as IFCC-HbA1c values in SI units (mmol HbA1c/mol Hb) and NGSP-HbA1c (%) as well as estimated average glucose (eAG), once a tight relationship has been shown to exist between eAG and HbA1c.
    Matched MeSH terms: Chemistry, Clinical/standards*
  3. Lee KN, Yoon SY, Cho HI
    PMID: 12755265
    The Asian Network for Clinical Laboratory Standardization (ANCLS) decided to start her First Inter-laboratory Quality Assurance survey at the business meeting during the Second Asian Colloquium on October 21-22, 2000 in Kobe, Japan. The first survey materials of Asian Quality Assurance Survey (AQuAS) were distributed in July 2001 to 21 hospitals in the field of chemistry and 22 hospitals in the field of hematology among total 24 participating laboratories from seven Asian countries: Indonesia, Japan, Korea, Malaysia, Philippines, Singapore and Thailand. The survey methods in chemistry and in hematology were somewhat different. In chemistry the survey material was considered as unknown but handled similarly to the sample from the patient. Nineteen routine tests were performed only once. The hematology samples were considered as unknown but handled similarly to control or calibration material. Five parameters were tested five times repetitively and their average for each parameter was calculated. All the results were supposed to be sent back to the office within two weeks. Although it took more than two weeks, the return rate was 100%. The analysis was performed in several ways such as all the results together, by instruments and by methods. Mean, standard deviation (SD), standard deviation index (SDI), coefficient of variation (CV) and variance index score (VIS) were to be calculated in chemistry, and in hematology the same parameter were to be calculated except CV and VIS. In the first survey, the CV in chemistry was not calculated and the analysis by instrument or by methodology was also not attempted since there were not enough participating hospitals to do such analysis. In hematology the analysis was done by instrument only. The survey process was carried out successfully though there were some difficulties in communication tools, transportation methods and handling of specimens due to different weather conditions, and returning the report in the correct unit and to the correct place. The submitted data were acceptable for analysis. There were some differences in the units of measurement in different countries or laboratories. It was necessary to convert some of the units. Some laboratories apparently do not perform certain tests such as calcium, potasium and gamma-glutamyltransferase (gamma-GT). The gamma-GT is the most frequently not performed test. With the experience of this first survey, all the members involved in the survey have been trained well to do future surveys.
    Matched MeSH terms: Chemistry, Clinical/standards*
  4. Wan Azman WN, Omar J, Koon TS, Tuan Ismail TS
    Oman Med J, 2019 Mar;34(2):94-98.
    PMID: 30918601 DOI: 10.5001/omj.2019.19
    Pre-analytical quality in clinical chemistry testing is as important as analytical and post-analytical quality. The most prevalent pre-analytical interference and a major source of error producing unreliable laboratory test results is hemolysis of blood samples. In vitro hemolysis may be due to the blood withdrawal technique or sample handling whereas in vivo hemolysis can originate from acquired, hereditary, or iatrogenic conditions and is not technique dependent. Interpreting in vivo or in vitro hemolysis requires clinicians to supply reliable clinical history and findings. Even then, to reject or release the result with interpretation is still under debate. Thus, hemolyzed specimens are a serious pre-analytical problem calling for well-designed and strictly implemented laboratory guidelines. The aim of this non-systematic review (addressed to healthcare professionals) was to highlight the challenges in identifying and rejecting hemolysis specimens.
    Matched MeSH terms: Chemistry, Clinical
  5. Chinnappan SM, George A, Evans M, Anthony J
    Food Nutr Res, 2020;64.
    PMID: 33061884 DOI: 10.29219/fnr.v64.3665
    Background: Interest in herbal medicines and non-hormonal therapies for the treatment of menopausal symptoms has increased since the publication of adverse effects of estrogen replacement therapy. Vasomotor symptoms are the most characteristic and notable symptoms of menopause.

    Objective: To investigate the changes in the frequency and severity of hot flush and associated vasomotor symptoms experienced by peri-menopausal and menopausal women supplemented with the herbal formulation (Nu-femme™) comprising Labisia pumila (SLP+®) and Eurycoma longifolia (Physta®) or placebo.

    Design: Randomised, double-blind, placebo-controlled, 24-week study enrolled 119 healthy women aged 41-55 years experiencing peri-menopausal or menopausal symptoms and supplemented with Nu-femme™ or placebo. The primary endpoint was comparative changes between treatment groups in the change in the frequency and severity of hot flushes. The secondary objectives were to assess the changes in the frequency and severity of joint pain, Menopause Rating Scale (MRS) and Menopause-Specific Quality of Life (MENQOL) questionnaire domain scores. Concentrations of serum hormone, lipid profile, bone markers, sleep quality and vitality were also studied as secondary objectives.

    Results: At week 12, significant (P < 0.01) improvements in hot flush symptoms were observed in Nu-femme™ and placebo groups. Even though there was no significant difference between groups, higher percentage of improvement, 65%, was seen in Nu-femme™ compared to 60% in placebo. Significant improvements (P < 0.001) in MRS and MENQOL scores at weeks 12 and 24 were observed in both groups, respectively. Luteinising hormone and follicle-stimulating hormone levels were significantly reduced (P < 0.05) at weeks 12 and 24, respectively, compared to baseline in the Nu-femme™ group, with no significant changes observed in the placebo group. There were significant (P < 0.05) reductions in serum low-density lipid and triglycerides levels at week 12 in Nu-femme™ group, but no changes seen in placebo group. At the end of week 24, changes in haematology and clinical chemistry parameters remained within normal clinical ranges in both groups.

    Conclusion: Herbal formulation consists of L. pumila and E. longifolia (Nu-femme™) may support reduction in hot flushes and improvements in hormone and lipid profile in healthy peri-menopausal and menopausal women.

    Matched MeSH terms: Chemistry, Clinical
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links