  1. Latiff HA, Alwi M, Kandhavel G, Samion H, Zambahari R
    Ann Thorac Surg, 1999 Oct;68(4):1400-1.
    PMID: 10543517
    A 10-month-old boy underwent operation to close a large secundum atrial septal defect and multiple muscular ventricular septal defects. Closure of the ventricular septal defects was unsuccessful and led to worsening cardiac failure and inability to wean the patient from mechanical ventilation. Transcatheter closure of the ventricular septal defects using Gianturco coils was undertaken. This technique is an effective alternative for closure of multiple muscular ventricular septal defects in infants and small children.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  2. Bilkis AA, Alwi M, Hasri S, Haifa AL, Geetha K, Rehman MA, et al.
    J Am Coll Cardiol, 2001 Jan;37(1):258-61.
    PMID: 11153748 DOI: 10.1016/s0735-1097(00)01094-9
    Objectives: The aim of the study was to assess the safety and efficacy of the Amplatzer ductal occluder (ADO) in transcatheter occlusion of patent ductus arteriosus (PDA).
    Background: Transcatheter closure of small to moderate sized PDAs is an established procedure. The ADO is a self-expandable device with a number of salutary features, notably its retrievability, ease of delivery via small 5F to 7F catheters and a range of sizes suitable even for the larger PDAs.
    Methods: Between November 1997 and August 1999, the ADO was successfully implanted in 205 of 209 patients with PDA. The inclusion criteria for this device occlusion method were patients with clinical and echocardiographic features of moderate to large PDA, weighing > or =3.5 kg as well as asymptomatic adolescents and adults with PDA measuring > or =5.0 mm on two-dimensional (2D) echocardiogram. Occlusion was achieved via the antegrade venous approach. Follow-up evaluations were performed with 2D echocardiogram, color-flow mapping and Doppler measurement of the descending aorta and left pulmonary artery velocity at 24 h and 1, 3, 6 and 12 months after implantation.
    Results: Two hundred and five patients had successful PDA occlusion using this device. The patients were between two months and 50 years (median 1.9) and weighed between 3.4 kg and 63.2 (median 8.4). Infants made up 26% of the total patients. The PDA measured from 1.8 to 12.5 mm (mean 4.9) at the narrowest diameter. Forty-four percent of patients achieved immediate complete occlusion. On color Doppler the closure rates at 24 h and 1 month after implant were 66% and 97%, respectively. At 6 and 12 months all except one patient attained complete occlusion. Device embolization occurred in three patients; in two this was spontaneous, and in the other it was due to catheter manipulation during postimplant hemodynamic measurement. Mild aortic narrowing was seen in an infant.
    Conclusions: Patent ductus arteriosus occlusion using ADO is safe and efficacious. It is particularly useful in symptomatic infants and small children with relatively large PDA. Embolization can be minimized by selection of appropriate sized devices, and caution should be exercised in infants <5 kg.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  3. Tay E, Muda N, Yap J, Muller DW, Santoso T, Walters DL, et al.
    Catheter Cardiovasc Interv, 2016 Jun;87(7):E275-81.
    PMID: 26508564 DOI: 10.1002/ccd.26289
    OBJECTIVES: The objective of this study is to describe and compare the use of the MitraClip therapy in mitral regurgitation (MR) patients with degenerative MR (DMR) and functional MR (FMR).

    INTRODUCTION: Percutaneous edge-to-edge repair of severe MR using the MitraClip device is approved for use in the USA for high risk DMR while European guidelines include its use in FMR patients as well.

    METHODS: The MitraClip in the Asia-Pacific Registry (MARS) is a multicenter retrospective registry, involving eight sites in five Asia-Pacific countries. Clinical and echocardiographic characteristics, procedural outcomes and 1-month outcomes [death and major adverse events (MAE)] were compared between FMR and DMR patients treated with the MitraClip.

    RESULTS: A total of 163 patients were included from 2011 to 2014. The acute procedural success rates for FMR (95.5%, n = 84) and DMR (92%, n = 69) were similar (P = 0.515). 45% of FMR had ≥2 clips inserted compared to 60% of those with DMR (P = 0.064).The 30-day mortality rate for FMR and DMR was similar at 4.5% and 6.7% respectively (P = 0.555). The 30-day MAE rate was 9.2% for FMR and 14.7% for DMR (P = 0.281). Both FMR and DMR patients had significant improvements in the severity of MR and NYHA class after 30 days. There was a significantly greater reduction in left ventricular end-diastolic diameter (P = 0.002) and end systolic diameter (P = 0.017) in DMR than in FMR.

    CONCLUSIONS: The MitraClip therapy is a safe and efficacious treatment option for both FMR and DMR. Although, there is a significantly greater reduction in LV volumes in DMR, patients in both groups report clinical benefit with improvement in functional class. © 2015 Wiley Periodicals, Inc.

    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  4. Abdul Aziz B, Alwi M
    Catheter Cardiovasc Interv, 1999 Oct;48(2):191-3.
    PMID: 10506777
    We report a case of a 14-month-old-infant with severe congenital mitral stenosis who presented with pulmonary oedema, acute renal failure and haemodynamic instability. Balloon dilatation was successfully performed under fluoroscopic and transesophageal echocardiographic guidance. Cathet. Cardiovasc. Intervent. 48:191-193, 1999.
    Matched MeSH terms: Cardiac Catheterization/instrumentation
  5. Alwi M, Budi RR, Mood MC, Leong MC, Samion H
    Cardiol Young, 2013 Apr;23(2):197-202.
    PMID: 22640635 DOI: 10.1017/S1047951112000595
    Objective: To determine the feasibility and safety of the Conquest Pro wire as an alternative to radiofrequency wire for perforation of atretic pulmonary valve and subsequent balloon dilatation and patent ductus arteriosus stenting in patients with pulmonary atresia with intact ventricular septum.
    Background: Radiofrequency valvotomy and balloon dilatation has become the standard of care for pulmonary atresia with intact ventricular septum in many institutions today.
    Methods: We report eight consecutive patients in whom we used the Conquest Pro coronary guidewire, a stiff wire normally reserved for revascularisation of coronary lesions with chronic total occlusion, for perforation of atretic pulmonary valve and subsequent balloon dilatation, and stenting of the patent ductus arteriosus.
    Results: Perforation of atretic pulmonary valve was successful in seven out of eight cases. Radiofrequency valvotomy was employed after failure of perforation by the Conquest Pro wire in one case where the right ventricular outflow tract was broad based and tapered towards the pulmonary valve, and was heavily trabeculated. Failure of the Conquest Pro wire to perforate the pulmonary valve plate was mainly attributed by the failure to engage the wire at the correct position.
    Conclusion: The Conquest Pro wire for perforation and subsequent interventions in the more straightforward cases of pulmonary atresia with intact ventricular septum is effective and safe, simplifying the entire procedure. However, the radiofrequency generator and wires remain essential tools in the paediatric interventional catheter laboratory.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  6. Latiff HA, Alwi M, Samion H, Kandhavel G
    Cardiol Young, 2002 May;12(3):224-8.
    PMID: 12365167
    This study reviewed the short-term outcome of transcatheter closure of the defects within the oval fossa using an Amplatzer Septal Occluder. From January 1997 to December 2000, 210 patients with defects within the oval fossa underwent successful transcatheter closure. We reviewed a total of 190 patients with left-to-right shunts, assessing the patients for possible complications and the presence of residual shunts using transthoracic echocardiogram at 24 h, 1 month, 3 months and one year. Their median age was 10 years, with a range from 2 to 64 years, and their median weight was 23.9 kg, with a range from 8.9 to 79 kg. In 5 patients, a patent arterial duct was closed, and in 2 pulmonary balloon valvoplasty performed, at the same sitting. The median size of the Amplatzer device used was 20 mm, with a range from 9 to 36 mm. The median times for the procedure and fluoroscopy were 95 min, with a range from 30 to 210 min, and 18.4 min, with a range from 5 to 144 min, respectively. Mean follow-up was 20.8 +/- 12.4 months. Complete occlusion was obtained in 168 of 190 (88%) patients at 24 h, 128 of 133 (96.2%) at 3 months, and 103 of 104 (99%) at one year. Complications occurred in 4 (2.1%) patients. In one, the device became detached, in the second the device embolized into the right ventricular outflow tract, the lower end of the device straddled in the third, and the final patient had significant bleeding from the site of venupuncture. There were no major complications noted on follow-up. We conclude that transcatheter closure of defects within the oval fossa using the Amplatzer Septal Occluder is safe and effective. Long-term follow-up is required, nonetheless, before it is recommended as a standard procedure.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  7. Zanjani KS, Wong AR, Sadiq M, Weber HS, Cutler NG
    Congenit Heart Dis, 2010 Sep-Oct;5(5):439-43.
    PMID: 21087429 DOI: 10.1111/j.1747-0803.2010.00448.x
    Objectives: There is little evidence in the medical literature about safety of PDA device closure and its effects on aortic root diameter in Marfan patients. We reported on nine Marfan patients whose ducts were occluded by coil or Amplatzer Duct Occluder.
    Patients and interventions: Two patients had aneurismal type E ducts which were closed by a single coil, respectively. The others had conical ducts for which even Amplatzer occluder, stiff, or double coils were used.
    Results: No untoward consequence was found during a median follow up period of 18.5 months (range 3 months to 6.33 years). Two patients had small residual shunts. The observed change in the mean ratio of aortic root diameter to its estimated value was statistically insignificant in seven patients who had complete data on their aortic root diameter before PDA closure and during the follow up.
    Conclusions: We concluded that PDA device closure in Marfan patients is safe. Risk of residual shunt is higher even after closure of small ducts.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  8. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Cardiac Catheterization/instrumentation*
  9. Alwi M, Choo KK, Radzi NA, Samion H, Pau KK, Hew CC
    J. Thorac. Cardiovasc. Surg., 2011 Jun;141(6):1355-61.
    PMID: 21227471 DOI: 10.1016/j.jtcvs.2010.08.085
    Objectives: Our objective was to determine the feasibility and early to medium-term outcome of stenting the patent ductus arteriosus at the time of radiofrequency valvotomy in the subgroup of patients with pulmonary atresia with intact ventricular septum and intermediate right ventricle.
    Background: Stenting of the patent ductus arteriosus and radiofrequency valvotomy have been proposed as the initial intervention for patients with intermediate right ventricle inasmuch as the sustainability for biventricular circulation or 1½-ventricle repair is unclear in the early period.
    Methods: Between January 2001 and April 2009, of 143 patients with pulmonary atresia and intact ventricular septum, 37 who had bipartite right ventricle underwent radiofrequency valvotomy and stenting of the patent ductus arteriosus as the initial procedure. The mean tricuspid valve z-score was -3.8 ± 2.2 and the mean tricuspid valve/mitral valve ratio was 0.62 ± 0.16.
    Results: Median age was 10 days (3-65 days) and median weight 3.1 kg (2.4-4.9 kg). There was no procedural mortality. Acute stent thrombosis developed in 1 patient and necessitated emergency systemic-pulmonary shunt. There were 2 early in-hospital deaths owing to low cardiac output syndrome. One late death occurred owing to right ventricular failure after the operation. Survival after the initial procedure was 94% at 6 months and 91% at 5 years. At a median follow-up of 4 years (6 months to 8 years), 17 (48%) attained biventricular circulation with or without other interventions and 9 (26%) achieved 1½-ventricle repair. The freedom from reintervention was 80%, 68%, 58%, and 40% at 1, 2, 3, and 4 years, respectively.
    Conclusions: Concomitant stenting of the patent ductus arteriosus at the time of radiofrequency valvotomy in patients with pulmonary atresia with intact ventricular septum and intermediate right ventricle is feasible and safe with encouraging medium-term outcome.
    Matched MeSH terms: Cardiac Catheterization/instrumentation*