Displaying all 6 publications

Abstract:
Sort:
  1. Mokhtar NH, Abas A, Razak NA, Hamid MNA, Teong SL
    J Theor Biol, 2017 11 21;433:73-84.
    PMID: 28844907 DOI: 10.1016/j.jtbi.2017.08.016
    Proper design of stent for application at specific aneurysm effect arteries could help to reduce the issues with thrombosis and aneurysm. In this paper, four types of stent configuration namely half-Y (6 mm), half-Y (4 mm), cross-bar, and full-Y configuration will implanted on real 3D artery bifurcation aneurysm effected arteries. Comparisons were then conducted based on the flow patterns after stent placement using both LBM-based solver and PIV experimental findings. According to the data obtained from all 4 stent designs, the flow profiles and the computed velocity from both methods were in agreement with each other. Both methods found that half-Y (6 mm) stent configuration is by far the best configuration in reducing the blood velocity at the vicinity of the aneurysm sac. The analysis also show that the half-Y (6 mm) stent configuration recorded the highest percentage of velocity reduction and managed to substantially reduce the pressure at the bifurcation region. This high flow velocity reduction through the use of half-Y stent could consequently promote the formation of thrombus thereby reducing the risk of rupture in the aneurysm sac.
    Matched MeSH terms: Aneurysm/therapy*
  2. Safari MJ, Wong JH, Kadir KA, Thorpe NK, Cutajar DL, Petasecca M, et al.
    Eur Radiol, 2016 Jan;26(1):79-86.
    PMID: 26002131 DOI: 10.1007/s00330-015-3818-9
    OBJECTIVES: To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures.

    METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures.

    RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions.

    CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose.

    KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.

    Matched MeSH terms: Intracranial Aneurysm/therapy
  3. Tan GJS, Khoo PLZ, Sailesh MK, Chan KMJ
    Med J Malaysia, 2019 02;74(1):67-78.
    PMID: 30846666
    INTRODUCTION: Aortic disease includes conditions such as chronic aortic aneurysms, acute aortic syndromes and congenital aortic abnormalities, amongst others. This paper reviews all research on aortic disease performed in Malaysia and published between 2000-2016.

    METHODS: A literature search was conducted in PubMed, Scopus, MyJurnal and the UKM Journal Repository. The search process was based on a previously published methodology. The medical subject headings (MeSH) search terms used were "aortic", "aorta" and "Malaysia".

    RESULTS: Two-hundred-thirteen papers were identified, of which 60 papers were selected and reviewed on the basis of their relevance. The epidemiology, pathophysiology, clinical presentations, case reports, investigations, treatment and outcomes of aortic disease in Malaysia were reviewed and summarised. The clinical relevance of the studies performed are discussed.

    CONCLUSION: The review provided an insight into the pathophysiology, prevalence and epidemiology of aortic diseases in Malaysia, how the condition is managed, and the outcomes of treatment. Limitations of the research performed in Malaysia to date were identified and recommendations for further research and improvement in clinical practice were recommended.

    Matched MeSH terms: Aortic Aneurysm/therapy
  4. Mehmood OU, Bibi S, Jamil DF, Uddin S, Roslan R, Akhir MKM
    Sci Rep, 2021 10 14;11(1):20379.
    PMID: 34650140 DOI: 10.1038/s41598-021-99499-z
    The current work analyzes the effects of concentric ballooned catheterization and heat transfer on the hybrid nano blood flow through diseased arterial segment having both stenosis and aneurysm along its boundary. A fractional second-grade fluid model is considered which describes the non-Newtonian characteristics of the blood. Governing equations are linearized under mild stenosis and mild aneurysm assumptions. Precise articulations for various important flow characteristics such as heat transfer, hemodynamic velocity, wall shear stress, and resistance impedance are attained. Graphical portrayals for the impact of the significant parameters on the flow attributes have been devised. The streamlines of blood flow have been examined as well. The present finding is useful for drug conveyance system and biomedicines.
    Matched MeSH terms: Aneurysm/therapy*
  5. Pany A, Sobri M, Valarmathi S, Latif AZ
    Med J Malaysia, 2004 Aug;59(3):422-4.
    PMID: 15727392
    A rare case of partially thrombosed giant serpentine right middle cerebral artery aneurysm presented. A 26 year old man initially presented with headache and 3 months later developed neurological deficit. Various stages of clot with patent residual lumen seen on neuroimaging, led to the diagnosis. Catheter angiography is the investigation of choice for evaluating the location, flow dynamics and extent of the serpentine aneurysm. The patient had embolisation done for the giant serpentine aneurysm.
    Matched MeSH terms: Intracranial Aneurysm/therapy
  6. Leong YP
    Med J Malaysia, 1991 Mar;46(1):51-8.
    PMID: 1836038
    Though peripheral arterial disease is not as common as in the Western countries, abdominal aorit aneurysm (AAA) is the most frequent arterial problem in Malaysia. A prospective study was made of 100 consecutive patients who presented with AAA to the author between January 1986 to September 1988 (31 months' period). There were 88 males and 12 females. The age range was 47-90 years, mean = 68.7. All the major ethnic rates were equally affected. The sizes of the AAA were documented by ultrasonography and the diameters ranged from 3-10 centimetres, mean = 5.8. Aneurysmectomy was performed on 58 patients, 17 of which were emergencies for ruptured AAA. The operative mortality for elective surgery was 2 percent, but that for emergency surgery was 47 percent. Ten patients refused surgery and 28 were not offered an operation. The true incidence of AAA is likely to be much higher than the number of patients referred for treatment. Many cases are not diagnosed or referred for treatment. Many cases of ruptured AAA died at home or in peripheral hospitals without a diagnosis being made. It is estimated that an AAA is present in 17,000 persons in Peninsular Malaysia. The risk of elective surgery is significantly lower than that of emergency. The overall mortality for ruptured AAA is even higher at about 99 percent. Furthermore, AAA is a benign disease and after surgery the patients return to their normal life expectancy. It is recommended that patients with AAA of five centimetres or more should be advised surgery if premature death is to be avoided.
    Matched MeSH terms: Aortic Aneurysm/therapy
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links