Displaying all 4 publications

Abstract:
Sort:
  1. Chew EE, Hashim NH, Wang CY
    Anaesth Intensive Care, 2010 Nov;38(6):1018-22.
    PMID: 21226431
    We compared the performance of the LMA Supreme (SLMA) with the I-Gel during anaesthesia in spontaneously breathing adult patients. Ninety patients with American Society of Anesthesiologists physical status I or II were studied in a prospective randomised controlled study. Our primary outcome measure was oropharyngeal leak pressure. We also compared the overall insertion success rate, ease of insertion, adequacy of ventilation and incidence of complications. The mean (SD), oropharyngeal leak pressure for the SLMA was 25.6 (5.1) cmH2O, which was greater than for the I-Gel 20.7 (5.9) cmH2O (P = 0.0001). The first attempt and overall insertion success rates were similar between the two groups (SLMA 97.8 and 97.8%; I-Gel 93.3 and 100%, P = 0.132). The SLMA was rated easier to insert than the I-Gel (P = 0.011), but the time taken for insertion (P = 0.433) was similar. The incidence of complications was low in both groups. The grade of fibreoptic view was better with the I-Gel than the SLMA (P = 0.001). We conclude that in adults with normal airways, the SLMA is easier to insert and provides a higher oropharyngeal leak pressure, but fibreoptic views are better with the i-gel.
    Matched MeSH terms: Anesthesia, General/instrumentation*
  2. Chaw SH, Shariffuddin II, Foo LL, Lee PK, Paran RM, Cheang PC, et al.
    J Clin Monit Comput, 2018 Dec;32(6):1093-1099.
    PMID: 29404890 DOI: 10.1007/s10877-018-0109-4
    To date, most of the studies on safety and efficacy of supraglottic airway devices were done in Caucasian patients, and the results may not be extrapolated to Asian patients due to the different airway anatomy. We conducted this study to compare Supreme™ LMA (SLMA) and Proseal™ LMA (PLMA) size 1.5 in anaesthetized children among an Asian population. This prospective randomized clinical trial was conducted in a tertiary teaching hospital from September 2013 until May 2016. Sixty children, weighing 5-10 kg, who were scheduled for elective surgery under general anaesthesia were recruited and completed the study. Patients were randomly assigned to have either SLMA or PLMA as the airway device for general anaesthesia, and standard anaesthesia protocol was followed. The primary outcome measured was the oropharyngeal leak pressure (OLP). The rate of successful insertion, insertion time, fibreoptic view of larynx and airway complications for each device were also assessed. There were no statistically significant differences between SLMA and PLMA size 1.5 in oropharyngeal leak pressure [19.1 (± 5.5) cmH2O vs. 19.8 (± 4.5) cmH2O, p = 0.68]. Secondary outcomes including time to insertion [20.8 (± 8.3) vs. 22.1 (± 8.3) s, p = 0.57], first attempt success rate for device insertion, fibreoptic view of larynx, and airway complications were also comparable between the two devices. We found that all the patients who had a failed device insertion (either PLMA or SLMA) were of a smaller size (5-6.2 kg). The oropharyngeal leak pressure of the SLMA 1.5 was comparable with the PLMA 1.5, and both devices were able to maintain an airway effectively without significant clinical complications in anaesthetized children from an Asian population.
    Matched MeSH terms: Anesthesia, General/instrumentation*
  3. Kumar Sinasamy T, Nazaruddin Wan Hassan WM, Hardy Mohamad Zaini R, Seevaunnamtum P, Ab Mukmin L
    Anaesthesiol Intensive Ther, 2020;52(5):383-388.
    PMID: 33327696 DOI: 10.5114/ait.2020.101407
    INTRODUCTION: The Baska mask and i-gel are two new types of second-generation supraglottic airway devices. The aim of this study was to compare these two devices in terms of quality of insertion, quality of ventilation and post-insertion complications.

    MATERIAL AND METHODS: A total of 80 adult patients who were scheduled for elective surgery under general anaesthesia were randomised to two groups: Group BM: Baska mask (n = 40) and Group IG: i-gel (n = 40). The assessment focused on ease of insertion, number of attempts, insertion time, number of corrective manoeuvres, oropharyngeal leak pressure, tidal volume, peak airway pressure (PAP) and post-insertion complications.

    RESULTS: Group IG showed a significantly shorter median insertion time (13.3 [interquartile range, IQR 7.8] vs. 17.0 [IQR 9.6] s; P < 0.001), a higher percentage in the 'very easy' ease of insertion category (62.5% vs. 10.0%; P < 0.001), a higher percentage in the no corrective manoeuvre category (92.5% vs. 72.5%; P = 0.003) and a higher percentage in the no post-operative throat pain category (67.5% vs. 32.5%; P = 0.011) than Group BM. However, Group BM showed a significantly higher generated PAP than Group IG (12.7 [1.8] and 11.5 [2.2] cm H2O, respectively; P = 0.010). There were no significant differences in other parameters.

    CONCLUSIONS: The i-gel was better than the Baska mask in terms of ease of insertion, speed of insertion, fewer corrective manoeuvres and less post-operative throat pain. However, the Baska mask had a better cuff seal, as shown by a higher generated PAP.

    Matched MeSH terms: Anesthesia, General/instrumentation
  4. Watts G
    Lancet, 2016 Sep 24;388(10051):1274.
    PMID: 27673462 DOI: 10.1016/S0140-6736(16)31669-5
    Matched MeSH terms: Anesthesia, General/instrumentation
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links