Displaying all 10 publications

Abstract:
Sort:
  1. Chia YY, Tay MG
    Dalton Trans, 2014 Sep 21;43(35):13159-68.
    PMID: 25032996 DOI: 10.1039/c4dt01098a
    The emission from transition metal complexes is usually produced from triplet excited states. Owing to strong spin-orbit coupling (SOC), the fast conversion of singlet to triplet excited states via intersystem crossing (ISC) is facilitated. Hence, in transition metal complexes, emission from singlet excited states is not favoured. Nevertheless, a number of examples of transition metal complexes that fluoresce with high intensity have been found and some of them were even comprehensively studied. In general, three common photophysical characteristics are used for the identification of fluorescent emission from a transition metal complex: emission lifetimes on the nanosecond scale; a small Stokes shift; and intense emission under aerated conditions. For most of the complexes reviewed here, singlet emission is the result of ligand-based fluorescence, which is the dominant emission process due to poor metal-ligand interactions leading to a small metal contribution in the excited states, and a competitive fluorescence rate constant when compared to the ISC rate constant. In addition to the pure fluorescence from metal complexes, another two types of fluorescent emissions were also reviewed, namely, delayed fluorescence and fluorescence-phosphorescence dual emissions. Both emissions also have their respective unique characteristics, and thus they are discussed in this perspective.
  2. Tay MH, Koo WH, Huang DT
    Med J Malaysia, 2002 Mar;57(1):51-5.
    PMID: 14569717
    A home care Hospice programme was set up to provide care to the patients with advanced diseases and their families in Singapore. After office-hour, the service is managed by a doctor on weekdays, with the assistance of a nurse during daytime on Saturdays, Sundays and public holidays. The doctor on-call made an average of 3.1 phone calls and 1.3 visits each weekday evening. Over the weekends and public holidays, there were a mean of 16.7 phone calls and 6 visits each day. More than half of the visits (50.3%) were made for certification of death. The commonest symptoms that prompted visits were dyspnoea (20%) and pain (12.2%). The busiest period during weekdays was between 6.00 pm and 11.00 pm, when our doctors did most of their visits. The workload of the hospice home care service is likely to increase and resources such as family health physicians can be explored to help to meet this increasing demand. This can be achieved through the provision of comprehensive training and easy accessibility to medical records which are kept with patients.
  3. Lim PE, Tay MG, Mak KY, Mohamed N
    Sci Total Environ, 2003 Jan 01;301(1-3):13-21.
    PMID: 12493181
    The objective of this study is to investigate the respective effects of Zn, Pb and Cd as well as the combined effect of Zn, Pb, Cd and Cu on the removal of nitrogen and oxygen demand in constructed wetlands. Four laboratory-scale gravel-filled subsurface-flow constructed wetland units planted with cattails (Typha latifolia) were operated outdoors and fed with primary-treated domestic wastewater at a constant flow rate of 25 ml/min. After 6 months, three of the wetland units were fed with the same type of wastewater spiked with Zn(II), Pb(II) and Cd(II), respectively, at 20, 5 and 1 mg/l for a further 9 months. The remaining unit was fed with the same type of wastewater spiked with a combination of Zn(II), Pb(II), Cd(II) and Cu(II) at concentrations of 10, 2.5, 0.5 and 5 mg/l, respectively, over the same period. The chemical oxygen demand (COD) and ammoniacal nitrogen (AN) concentrations were monitored at the inlet, outlet and three additional locations along the length of the wetland units to assess the performance of the wetland units at various metal loadings. At the end of the study, all cattail plants were harvested for the determination of total Kjeldahl nitrogen and metal concentrations. The results showed that the COD removal efficiency was practically independent of increasing metal loading or a combination of metal loadings during the duration of the study. In contrast, the AN removal efficiency deteriorated progressively with increasing metal loading. The relative effect of the heavy metals was found to increase in the order: Zn
  4. Soo CS, Ca M, Tay M, Yeoh JK, Sim E, Choo M
    J Am Soc Echocardiogr, 1994 3 1;7(2):159-64.
    PMID: 8185960
    We prospectively studied 37 consecutive patients implanted with the Carbomedics prosthetic heart value in the mitral position (without clinical evidence of prosthetic valve dysfunction) with two-dimensional and Doppler echocardiography. The peak mitral prosthetic gradient ranged from 4.60 to 14.63 (mean 8.97 +/- 2.29) mm Hg; mean mitral prosthetic gradient ranged from 1.67 to 6.18 (mean 3.24 +/- 0.95) mm Hg; pressure half-time derived mitral valve area ranged from 1.67 to 5.30 (mean 2.70 +/- 0.80) cm2. These values compare favorably with that of another bileaflet valve (i.e., the St. Jude Medical valve). There was a wide overlap in peak and mean transmitral gradients, even with the valves of the same size, with a significant but weak inverse relationship between peak mitral gradients and valve size (p = 0.03, r = -0.36). The performance index showed a smaller range of values, again with a significant but weak inverse relationship with valve size (p = 0.001, r = -0.54). The inverse relationship between valve size and peak mitral gradient and performance index should be borne in mind when analyzing Doppler hemodynamic data.
  5. Caiazzo G, Oliva A, Testa L, Heang TM, Lee CY, Milazzo D, et al.
    Cardiovasc Diabetol, 2024 Feb 03;23(1):52.
    PMID: 38310281 DOI: 10.1186/s12933-024-02139-9
    BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons.

    AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India).

    METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings.

    RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status.

    CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.

  6. Sciahbasi A, Salvi N, Heang TM, Perez IS, Geraci S, Vaccaro G, et al.
    Catheter Cardiovasc Interv, 2024 Mar;103(4):532-538.
    PMID: 38415895 DOI: 10.1002/ccd.30996
    BACKGROUND: Studies evaluating the safety and efficacy of drug coating balloons (DCB) for the treatment of lesions in large coronary vessel are limited.

    AIMS: Our study aimed to evaluate the performance of a sirolimus DCB in large coronary arteries.

    METHODS: We analyzed all the procedures included in the EASTBOURNE Registry (NCT03085823) enrolling patients with a clinical indication to percutaneous coronary intervention performed by a sirolimus DCB according to investigator judgment. In the present analysis, a cut-off of 2.75 mm was used to define large coronary arteries. Primary endpoint of the study was clinically driven target lesion revascularization (TLR) at 24 months whereas secondary endpoint included procedural success, myocardial infarction (MI), cardiac death and total mortality.

    RESULTS: Among the 2123 patients and 2440 lesions enrolled in the EASTBOURNE study between 2016 and 2020, 757 patients/810 lesions fulfilled the criteria for the present analysis. Mean reference vessel diameter was 3.2 ± 0.3 mm with mean lesion length of 22 ± 7 mm. Procedural success was high (96%) and at 2-year follow up the device showed a good efficacy with a TLR rate of 9%. There were 34 deaths (4.5%), 30 MIs (4%) and 8 BARC type 3-5 bleedings (1.1%). In-stent restenosis (629 lesions) and de novo lesions (181) were associated with 11% and 4% rates of TLR at 2 years, respectively (p = 0.003).

    CONCLUSIONS: Clinical performance of a sirolimus DCB in large coronary artery vessels shows promising signals at 2-year follow up, both in de novo and in-stent restenosis lesions.

  7. Cortese B, Testa L, Di Palma G, Heang TM, Bossi I, Nuruddin AA, et al.
    J Cardiovasc Med (Hagerstown), 2021 02 01;22(2):94-100.
    PMID: 32740442 DOI: 10.2459/JCM.0000000000001070
    AIMS: The purpose of the EASTBOURNE registry is to evaluate the immediate and long-term clinical performance of a novel sirolimus-coated balloon (SCB) in a real-world population of patients with coronary artery disease. We here present the prespecified interim analysis after the enrollment of the first 642 patients who obtained 1-year clinical follow-up.

    METHODS: EASTBOURNE is a prospective, international, multicenter, all-comer investigator-driven clinical registry, which is enrolling consecutive patients treated with SCB at 42 European and Asiatic centers. Primary study endpoint is target-lesion revascularization (TLR) at 12 months. Secondary endpoints are procedural success and major adverse cardiac events through 36 months.

    RESULTS: Diabetes mellitus was present in 41% of patients. Acute coronary syndrome was present in 45% of patients and de novo lesions were 55%; 83% of the in-stent restenosis (ISR) patients had drug-eluting stents restenosis. Lesion predilatation was performed in 95% of the cases and bailout stenting occurred in 7.5%. So far, 642 patients have a complete 12-month follow-up. TLR occurred in 2.5%, myocardial infarction in 2.3%, total death in 1% and major adverse cardiac events in 5.8% of patients. A prespecified analysis of comparison between ISR and de-novo lesions showed a significantly higher occurrence of TLR in the ISR population (5.4 vs. 0.2%, P = 0.0008).

    CONCLUSION: The current interim analysis of 12-month follow-up of the EASTBOURNE registry shows good immediate performance and an adequate and encouraging safety profile through 12 months for this novel SCB.

  8. Mangier A, Testa L, Heang TM, Bossi I, Lee CY, Perez IS, et al.
    Cardiovasc Revasc Med, 2024 Jul 30.
    PMID: 39191613 DOI: 10.1016/j.carrev.2024.07.024
    BACKGROUND: Drug coated balloons (DCB) are potentially less thrombogenic than drug eluting stents (DES).

    AIMS: To explore the safety and the feasibility of single antiplatelet therapy in percutaneous coronary intervention with sirolimus-coated balloons.

    METHODS: The All-comers Sirolimus-coated Balloon European Registry (EASTBOURNE) is a prospective investigator-driven registry assessing the performance of a novel sirolimus-coated balloon (SCB) in a real-world population. This prespecified post hoc analysis aimed at comparing the outcome in patients prescribed either single antiplatelet therapy (SAPT) or dual antiplatelet therapy (DAPT); choice of antiplatelet agent and duration of the regimen were at operator's discretion in both groups. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were bleeding grade 3-5 according to The Bleeding Academic Research Consortium (BARC) criteria and major adverse cardiovascular events (MACE) at 12 months follow-up.

    RESULTS: Among 2123 patients enrolled in the study between September 2016 and November 2020, 113 patients (5.8 %) received SAPT while 1826 patients (94.1 %) received DAPT after SCB. The majority of the patients underwent DCB PCI for de novo lesions (n = 1091, 56.3 %) while 848 patients (47.7 %) had DCB revascularization for in-stent restenosis. No cases of TLR occurred in the SAPT group within one month after the index procedure, and no acute occlusive events were recorded during follow up in patients taking a single antiplatelet agent. Moreover, no differences in terms of TLR were observed between SAPT vs DAPT regimens nor in case of de novo treatment with an overall rate of TLR at 12 months of 7.7 % for SAPT and 5.6 % for DAPT (p = 0.6). The cumulative rate of MACE at 12 months was not different between SAPT and DAPT regimens (n = 12 [11.2 %] vs. n = 162 [8.9 %], p = 0.4), and results were consistent in the de novo and in-stent restenosis groups.

    CONCLUSIONS: Our post hoc analysis of the EASTBOURNE registry suggests that the use of single antiplatelet agent after sirolimus-DCB PCI for both de novo or in-stent restenosis lesions is safe and effective and can help to contain the risk of bleeding in a selected population.

    CONDENSED ABSTRACT: The manuscript aims to explore the feasibility of a single antiplatelet regimen following angioplasty using drug coated balloon with sirolimus. Among 2123 patients treated with sirolimus coated balloon (SCB), 113 patients (5.8 %) received a single antiplatelet therapy (SAPT) while 1826 patients (94.1 %) received dual antiplatelet therapy DAPT. No cases of target lesion revascularization occurred in the SAPT group within one month after the index procedure, and no acute occlusive events were recorded during follow up in patients taking a single antiplatelet agent. The cumulative rate of major adverse cardiovascular events at 12 months was not different between SAPT and DAPT regimens and results were consistent in the de novo and in-stent restenosis groups.

  9. Cortese B, Testa L, Heang TM, Ielasi A, Bossi I, Latini RA, et al.
    JACC Cardiovasc Interv, 2023 Jul 24;16(14):1794-1803.
    PMID: 37495352 DOI: 10.1016/j.jcin.2023.05.005
    BACKGROUND: Drug-coated balloons (DCB) represent 1 of the most promising innovations in interventional cardiology and may represent a valid alternative to drug-eluting stents. Currently, some sirolimus-coated balloons (SCB) are being investigated for several coronary artery disease applications.

    OBJECTIVES: This study sought to understand the role of a novel SCB for the treatment of coronary artery disease.

    METHODS: EASTBOURNE (All-Comers Sirolimus-Coated Balloon European Registry) is a prospective, multicenter, investigator-driven clinical study that enrolled real-world patients treated with SCB. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were procedural success, myocardial infarction (MI), all-cause death, and major adverse clinical events (a composite of death, MI, and TLR). All adverse events were censored and adjudicated by an independent clinical events committee.

    RESULTS: A total population of 2,123 patients (2,440 lesions) was enrolled at 38 study centers in Europe and Asia. The average age was 66.6 ± 11.3 years, and diabetic patients were 41.5%. De novo lesions (small vessels) were 56%, in-stent restenosis (ISR) 44%, and bailout stenting occurred in 7.7% of the patients. After 12 months, TLR occurred in 5.9% of the lesions, major adverse clinical events in 9.9%, and spontaneous MI in 2.4% of the patients. The rates of cardiac/all-cause death were 1.5% and 2.5%, respectively. The primary outcome occurred more frequently in the ISR cohort (10.5% vs 2.0%; risk ratio: 1.90; 95% CI: 1.13-3.19). After multivariate Cox regression model, the main determinant for occurrence of the primary endpoint was ISR (OR: 5.5; 95% CI: 3.382-8.881).

    CONCLUSIONS: EASTBOURNE, the largest DCB study in the coronary field, shows the safety and efficacy of a novel SCB in a broad population of coronary artery disease including small vessels and ISR patients at mid-term follow-up. (The All-Comers Sirolimus-Coated Balloon European Registry [EASTBOURNE]; NCT03085823).

Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links