Displaying all 2 publications

Abstract:
Sort:
  1. Zaini Hamzah, Mohd Najif Ab Rahman, Siti Mariam Sumari, Yamin Yasin, Ahmad Saat
    MyJurnal
    Layered double hydroxide (LDH) with Mg/Al molar ratio of 4/1 (MAN-4) was synthesized by co-precipitation and followed by hydrothermal method. The compound was allowed to undergo ion exchange with K2HPO4 for 48 hours to produce MgAlHPO4 (MAHP-4). The solid produced was characterized using X-ray diffraction (XRD) and Fourier Transform Infrared spectroscopy (FTIR). Adsorption of copper solution by MAHP-4 was carried out using batch experiment by mixing the copper solution and the sorbent MAHP-4. The effects of
    various parameters such as contact time, pH, adsorbent dosage and initial concentration were investigated. The optimum pH for copper removal was found to be 4 and the optimum time of copper removal was found at 4 hours. The isotherm data was analysed using model isotherm Langmuir with the correlation coefficient of 0.999 was recorded. The maximum adsorption capacity, Qo (mg/g) of 142.8 mg/g was also recorded from the Langmuir isotherm. The remaining copper solution was determined by using EDXRF (Energy Dispersive XRay Fluorescence spectrometry) model MiniPal 4 (PAN analytical). The results in this study indicate that MAHP-4 has potential as an effective adsorbent for removing copper from aqueous solution.
  2. Ahmad Saat, Zaini Hamzah, Zaharidah Abu Bakar, Zuraidah A. Munir, Siti Mariam Sumari, Misbah Hassan
    MyJurnal
    A study was carried out to determine short term diurnal radon concentration at five locations in Malaysia. Two locations (KG & AP) are former tin mining areas that has been converted to housing area and training centre respectively, one a relatively new city (SA), that was formerly a rubber and oil palm plantation area, one older cities (KB) and one housing complex by the sea (LP). The study was carried out in 2005, 2006 and 2007 using a diffused-junction photodiode sensor continuous radon monitor. The monitor is recognized by the USEPA. In each location, measurements were carried out on at least ten sites. Former tin mining areas of KG and AP shows up to seven times higher indoor average than the average in the other three locations. However the indoor average in all locations is still below the action level of 4 pCiL-1. For outdoor, the former tin mining areas average concentration was higher than the global average of 0.4 pCiL-1. For the twenty four hours temporal variation the trend indicated that former tin mining areas concentration are always higher, and at time up to six fold higher. The hourly variation of all locations follows an identical trend of high concentration during early to late morning and drop in the afternoon till evening. The outdoor twenty four hour temporal average of former tin mining areas is consistently higher than the outdoor global average of 0.4 pCiL-1. The strong correlation between indoor and outdoor concentration at AP, indicates that indoor radon might originates from outdoor environment. The study was also extended to estimate the effective dose (mSvyr-1) of Rn-222 to the public.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links