Methods: Seven patients with acute grade 1 ankle sprain (15 days of ankle sprain) were recruited. They were provided with 7 days of protection, optimal loading, ice, compression, and elevation (POLICE) treatment, and the standard physiotherapy programme consisted of towel stretching and balancing exercises on one leg. Pain scale score was recorded daily during the physiotherapy programme. The isokinetic ankle strengths of the patient's injured and uninjured legs were compared before and after the physiotherapy programme. Isokinetic tests were conducted in painless range of motion for the injured leg.
Results: Pain was significantly reduced after the patients underwent the standard physiotherapy programme. No significant differences were observed in terms of the ankle peak torque, time to peak torque, and ankle plantar flexion-to-dorsiflexion ratio of the injured and uninjured legs. The injured leg showed significant improvement in terms of ankle eversion-to-inversion ratio (E:I) after 7 days of performing the standard physiotherapy programme.
Conclusion: Performing the standard physiotherapy programme for 1 week reduces pain and improves the ankle E:I in patients with grade 1 ankle sprain.
Materials and Methods: In this in-vitro study, a total of 48 single-rooted permanent human teeth were decoronated, and the roots were treated endodontically. Following post space preparation, the sample was divided into four groups (n= 12 each) based on the types of post and cement. Two different types of post [GC everStick®POST (ES) and Parapost® Fiber LuxTM (PF)], and two different types of cement [G-CEMTM (G), and RelyXTM Unicem (R)] were used according to the manufacturer's instructions. All roots were sectioned at the coronal and middle thirds with a thickness of 3±0.1mm. The Push-out bond strength (PBS) test was performed using a universal testing machine at a cross-head speed of 0.5mm/ min. The bond strength values were recorded, and the data were analyzed using the SPSS program. Apart from descriptive statistics, three-way ANOVA was used for the interaction of the independent variables (post, cement, and root level). For differences between the groups, the Mann-Whitney U test was used. A P-value of less than 0.05 was considered significant for all analyses.
Results: Push-out bond strength of samples at the middle level (11.38±10.31 MPa), with PF posts (11.18±9.98 MPa), and of those luted with RelyXTM Unicem cement (13.26±8.73 MPa) was higher than that of their counterparts. The PBS means of RelyXTM Unicem cement at both root levels were much higher than PBS means of G-CEMTM cement. Three-way ANOVA test revealed a significant effect for each variable with a higher effect of cement (Sum of Squares= 1310.690; P< 0.001). No significant difference (P= 0.153) was found between the coronal and middle parts and between ES and PF posts (P= 0.058). However, a highly significant difference (P< 0.001) was found between RelyXTM Unicem and G-CEMTM cements.
Conclusion: The type of cement had a significant effect on push-out bond strength with RelyXTM Unicem which had higher values than G-CEMTM. However, the type of post and root level had no significant effect on PBS, although Parapost® Fiber LuxTM and middle root level had higher values than their counterparts.
MATERIALS AND METHODS: Three search engines (Google, Yahoo!, and Bing) were searched. The first 20 consecutive websites from each engine were obtained and checked for eligibility. For the quality of the websites, the Health on the Net Foundation Code of Conduct (HONcode), the DISCERN tool, the Journal of the American Medical Association (JAMA) Benchmarks, and Google PageRank were used for the assessment of the included websites. For readability, an online web tool was used, including well-known analyzing indices [Flesch Kincaid grade level (FKGL), Simple Measure of Gobbledygook (SMOG), and Flesch Reading Ease (FRE)]. The acceptable readability level was set to be ≥80.0 for the FRE and <7 for the FKGL and SMOG. The data were presented in frequencies and percentages.
RESULTS: Out of the 60 screened websites, 14 websites were eligible for analysis. There was only one (7.1%) website that had the HONcode seal. The mean score of all websites based on the DISCERN tool was 29.6 ± 12.1, with no website achieved the high score (≥65). Only one (7.1%) website scored >5 based on Google PageRank. Regarding JAMA benchmarks, all websites achieved a mean score of 2.57 ± 1.1. The mean grade level based on the FKGL was 8.4 ± 6.3. All websites had a score of <7 according to the SMOG index. The mean score of the readability ease index was 90.5 ± 16.4.
CONCLUSION: Most of the dental health information on denture hygiene available on the Arabic websites did not have the required level of quality, regardless of being readable and comprehensible by most of the general people.
CLINICAL SIGNIFICANCE: Directing the patients to the appropriate websites related to their cases is the responsibility of the dentists.