Displaying 1 publication

Abstract:
Sort:
  1. Musa, S., Radzi, M.A.M.
    MyJurnal
    This research presents compensation of current harmonic disturbance in power system network using
    shunt active power filter. In this paper, harmonic extraction using Synchronous Reference Frame
    Fundamental technique (SRFF) was investigated for three phase 3-wire system. It proposes a method
    based on direct current measurement of load currents using a band pass filter at low cut off frequencies
    to improve the filtering ability in highly contaminated loads. The proposed filter consists of second
    order low pass and high pass filters cascaded together at suitable frequencies, estimated based on the
    output of these units to mitigate the current harmonics. The performance of the system was simulated
    in Matlab Platform and evaluated considering total harmonic distortion of the source current in a threephase
    balanced network. The simulation results show the ability of the proposed tracking scheme to
    accurately estimate harmonics.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links