Displaying all 3 publications

Abstract:
Sort:
  1. Nizar SA, Mohd Suah FB
    J Fluoresc, 2016 Jul;26(4):1167-71.
    PMID: 27286697 DOI: 10.1007/s10895-016-1845-9
    The effect of room temperature ionic liquid (RTIL) on the formation of the fluorescence ternary complex oxalate-sodium morin-5-sulfonate (NaMSA)-Aluminium(III) has been studied. In weakly acidic medium and in the presence of RTIL, 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6), total complex formation is achieved as compared with the formation of the binary complex of NaMSA-Aluminium(III). The fluorescence characteristics of the system allowed the establishment of a very sensitive method for the spectrofluorimetric determination of oxalate ion. The ternary complex formed its highest fluorescence signal at 513 nm and excitation at 420 nm. In these conditions, the method produces a detection limit of 0.57 ng mL(-1). The procedure has been satisfactorily applied to the determination of oxalate ion in a vegetal tissue (spinach leaves).
  2. Nizar SA, Kobayashi T, Mohd Suah FB
    Luminescence, 2020 Dec;35(8):1286-1295.
    PMID: 32525612 DOI: 10.1002/bio.3890
    This paper describes the synthesis of poly(1-aminonaphthalene) and its application as a chemosensor for detection of Fe3+ using the naked eye and a fluorimetric method. The conjugated polymer was synthesized by chemical oxidative polymerization using FeCl3 as a catalyst. The response of the polymer towards various metal ions was investigated using colorimetric detection, and ultraviolet-visible and fluorescence spectroscopies. The polymer displayed high selectivity and sensitivity towards Fe3+ compared with other metal ions. A significant colour change from purple to yellow was observed upon addition of Fe3+ by the naked eye. The polymer also showed a high selectivity and sensitivity 'turn-off' fluorescence response towards Fe3+ ions. A good linear response was obtained for Fe3+ concentrations in the range 10-50 mg L-1 with a detection limit of 1.04 mg L-1 . The proposed chemosensor was applied for determination of Fe3+ content in water samples and satisfactory results were obtained.
  3. Alshammari AH, Alqahtani Z, Mohd Suah FB, Nizar SA, Dunbar A, Grell M
    Anal Chim Acta, 2020 Apr 08;1105:1-10.
    PMID: 32138906 DOI: 10.1016/j.aca.2020.01.070
    Morin dye is known as a cheap and readily available selective 'off → on' fluorescent sensitiser when immobilised in a phase transfer membrane for the detection of Al3+ ions. Here, a morin derivative, NaMSA, which readily dissolves in water with good long-term stability is used in conjunction with a fibre optic transducer with lock-in detection to detect Al3+ in drinking water below the potability limit. The combination of a water soluble dye and the fibre optic transducer require neither membrane preparation nor a fluorescence spectrometer yet still display a high figure-of- merit. The known ability to recover morin-based Al3+ cation sensors selectively by exposure to fluoride (F-) anions is further developed enabling a complementary sensing of either fluoride anions, or aluminium cations, using the same dye with a sub-micromolar limit-of-detection for both ions. The sensor performance parameters compare favourably to prior reports on both aqueous aluminium and fluoride ion sensing.