Displaying all 5 publications

Abstract:
Sort:
  1. Chew KS, Low MY
    Med J Malaysia, 2022 Jan;77(1):60-70.
    PMID: 35086996
    BACKGROUND: A scoping review was conducted to map out the common research focusses on ambulance accidents, their key findings and some of the major knowledge gaps in this area.

    MATERIALS AND METHODS: Relevant, peer-reviewed, Englishlanguage articles on land ambulance accidents were independently searched by the authors using the MEDLINE and CINAHL databases. Anecdotal reports, testimonies and stories in trade or popular magazines and other grey literature were excluded. Articles that do not directly address ambulance accidents were also excluded. Additional articles were identified from the reference lists of the selected articles and from Google search engine.

    RESULTS: From an initial yield of 879 articles, 19 articles were included. Most of these articles were published from 2001 - 2005 (5 articles, 26.3%) and 2006 - 2010 (5 articles, 26.3%). Eighteen articles (78.3%) are original articles (18 articles, 78.3%) and another one article is a review article. Most of these articles focused on (1) the types of collisions and (2) the risk factors of ambulance accidents. Nine risk factors were identified to have contributed to ambulance accidents: (1) driving in urban areas (2) driving on dry road (3) the use of lights & sirens (4) the failure to use restraints (5) driving for emergency use (6) back seating (7) at road intersection (8) driver's previous records of accidents and (9) interfacility transfer. The two most common risk factors studied were (1) the use of lights & sirens and (2) driving at intersection.

    CONCLUSIONS: Most of the above risk factors can be mapped into three categories of risk factors: task-related factors, vehicle-related factors and environment-related factors. The category of risk factors least studied is the category of driver-related factors.

  2. Zeng Y, Xu Y, Kee CL, Low MY, Ge X
    Drug Test Anal, 2016 Mar;8(3-4):351-6.
    PMID: 26305055 DOI: 10.1002/dta.1846
    In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) with scheduled multiple reaction monitoring (MRM) enhanced product ion (EPI) method was developed for simultaneous determination of 40 compounds with weight loss effect, including bisacodyl, phenolphthalein, and sibutramine and its metabolites, etc. They might be adulterated in health supplements to get prominent weight loss effect. The samples were analyzed using a Q-Trap 5500 coupled with high performance liquid chromatography (HPLC) and a CORTECS ultra performance liquid chromatography (UPLC) C18 column (100 mm x 2.1 mm x1.6 µm). Scheduled MRM was used as survey scan, MS2 spectra acquired in the EPI mode were used to perform library searching to increase the confidence of detection. Limits of detection were less than 10 ng/g for the majority of the analytes. A total of 447 weight loss products were tested in our laboratory in the past three years. Among these samples, 119 samples were found to be adulterated with one or more weight loss compounds, including sibutramine, its metabolites benzyl sibutramine and desmethyl sibutramine; phenolphthalein; bisacodyl; furosemide; liothyronine (T3); and thyroxine (T4). Copyright © 2015 John Wiley & Sons, Ltd.
  3. Cheah JM, Ng D, Low MY, Foo SH
    J ASEAN Fed Endocr Soc, 2019;34(2):206-209.
    PMID: 33442157 DOI: 10.15605/jafes.034.02.12
    Thyroid crisis is a life-threatening form of thyrotoxicosis characterized by multi-system dysfunction. Therapeutic plasma exchange has been reported to be effective in removing excessive circulating thyroid hormones. We present a 46-year-old female with recently diagnosed Graves' disease associated with thyrotoxic cardiomyopathy admitted for thyroid crisis complicated by propranolol-induced circulatory collapse, acute kidney injury and ischemic hepatitis. The tachyarrhythmia was refractory to conventional therapy. Initiation of TPE resulted in rapid clinical and biochemical stabilization.
  4. Mokhtar SU, Chin ST, Kee CL, Low MY, Drummer OH, Marriott PJ
    J Pharm Biomed Anal, 2016 Mar 20;121:188-196.
    PMID: 26808068 DOI: 10.1016/j.jpba.2016.01.034
    Application of gas chromatography-triple quadrupole mass spectrometry for identification, confirmation and quantification of 6 phosphodiesterase-5 (PDE-5) inhibitors (sildenafil, dimethylsildenafil, homosildenafil, thiosildenafil, thiodimethylsildenafil and thiohomosildenafil) in dietary supplements was investigated. The MS was operated in multiple reaction monitoring mode, for better sensitivity and selectivity. In this manner, the method is adequate to reduce background noise with less interference from co-eluting compounds in the samples. Two different ionisation techniques, electron ionisation (EI) and chemical ionisation (CI), were studied and compared. The chromatographic separation was performed on a short 10 m non-polar capillary column without any derivatisation step. This permitted fast analysis for all analogues with retention time less than 11 min, for both techniques. Use of backflushing can aid method retention time reduction and improves column maintenance. Evaluation of method validation included limit of detection (LOD), lower limit of quantitation (LLOQ), linearity, precision and recovery were performed for both EI and CI techniques. The LOD obtained varied from 0.03 to 1.50 μg/g and the LLOQ ranged from 0.10 to 5.00 μg/g. Good calibration linearity was obtained for all analogues for both techniques, with correlation coefficients (r(2)) higher than 0.99. Mean recoveries of all analogues using CI show higher values (83.4-108.8%) than that of EI (61.9-91.1%). The intra- and inter-assay precisions were evaluated for all analogues at spiked concentration of 10 μg/g and the relative standard deviation was less than 15% for both methods. These methods were then successfully applied to dietary supplement samples without prior derivatisation, confirming that the samples were adulterated with sildenafil and/or its analogues.
  5. Lee TJ, Wan Rahimi WFB, Low MY, Nurruddin AA
    Eur Heart J Case Rep, 2021 Dec;5(12):ytab432.
    PMID: 34993399 DOI: 10.1093/ehjcr/ytab432
    Background: Intravascular lithotripsy is a new method used to treat calcified coronary lesions (CCLs). Percutaneous coronary intervention of CCLs has conventionally been classified as a complex procedure. In the majority of calcified cases, atherectomy is required for sufficient plaque modification prior to stent implantation. Intravascular lithotripsy has been shown to be safe and effective in clinical trials, but as worldwide usage increases, cases of complications are beginning to emerge.

    Case summary: We describe a 71-year-old woman, who after an episode of non-ST-elevation acute coronary syndrome underwent coronary angiography. The culprit vessel was identified to be a severely stenosed left anterior descending artery which was also heavily calcified and tortuous. Intravascular lithotripsy (IVL) was employed for calcium modification prior to stent implantation, but the IVL balloon ruptured during shockwave lithotripsy, resulting in coronary artery dissection. Subsequent management steps and stent deployment resulted in favourable angiographic results. Our findings are further detailed on optical coherence tomography, demonstrating certain features which might predispose to IVL balloon rupture.

    Discussion: We discuss the mechanism of action during intravascular lithotripsy, and how the shockwaves from the lithotripter modify calcified lesions, whilst keeping soft tissue unharmed. Results from clinical trials and multiple real-world studies have shown that complication rates are low. This case report aims to illustrate how the rupture of an intravascular lithotripsy balloon can result in coronary artery dissection. Optical coherence tomography can help in identifying potential anatomical features which may precede such complications.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links