Displaying all 3 publications

Abstract:
Sort:
  1. Kwon WK, Sung TY, Yu GY, Sidik H, Kang WS, Lee Y, et al.
    J Anesth, 2016 Apr;30(2):223-31.
    PMID: 26577248 DOI: 10.1007/s00540-015-2094-9
    BACKGROUND: The direct impact of sevoflurane on intraoperative left ventricular (LV) systolic performance during cardiac surgery has not been fully elucidated. Peak systolic tissue Doppler velocities of the lateral mitral annulus (S') have been used to evaluate LV systolic long-axis performance. We hypothesized that incremental sevoflurane concentration (1.0-3.0 inspired-vol%) would dose-dependently reduce S' in patients undergoing cardiac surgery due to mitral or aortic insufficiency.

    METHODS: In 20 patients undergoing cardiac surgery in sevoflurane-remifentanil anesthesia, we analyzed intraoperative S' values which were determined after 10 min exposure to sevoflurane at 1.0, 2.0, and 3.0 inspired-vol% (T1, T2, and T3, respectively) with a fixed remifentanil dose (1.0 μg/kg/min) using transesophageal echocardiography.

    RESULTS: Linear mixed-effect modeling demonstrated dose-dependent declines in S' according to the end-tidal sevoflurane concentration increments (C(ET)-sevoflurane, p < 0.001): the mean value of S' reduction for each 1.0 vol%-increment of C(ET)-sevoflurane was 1.7 cm/s (95 % confidence interval 1.4-2.1 cm/s). Medians of S' at T1, T2, and T3 (9.6, 8.9, and 7.5 cm/s, respectively) also exhibited significant declines (by 6.6, 15.6, and 21.2 % for T1 vs. T2, T2 vs. T3, and T1 vs. T3, p < 0.001, =0.002, and <0.001 in Friedman pairwise comparisons, respectively).

    CONCLUSIONS: Administering sevoflurane as a part of a sevoflurane-remifentanil anesthesia regimen appears to dose-dependently reduce S', indicating LV systolic performance, in patients undergoing cardiac surgery. Further studies may be required to evaluate the clinical implications of these findings.

  2. Jung HJ, Kwon WK, Lee SJ, Mohamed N, Shin BM, Lee J, et al.
    BMC Anesthesiol, 2016 10 04;16(1):83.
    PMID: 27716083
    BACKGROUND: This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography.

    CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.

    CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.

  3. Kim JD, Son I, Kwon WK, Sung TY, Sidik H, Kim K, et al.
    J Korean Med Sci, 2018 01 22;33(4):e28.
    PMID: 29318795 DOI: 10.3346/jkms.2018.33.e28
    BACKGROUND: Isoflurane, a common anesthetic for cardiac surgery, reduced myocardial contractility in many experimental studies, few studies have determined isoflurane's direct impact on the left ventricular (LV) contractile function during cardiac surgery. We determined whether isoflurane dose-dependently reduces the peak systolic velocity of the lateral mitral annulus in tissue Doppler imaging (S') in patients undergoing cardiac surgery.

    METHODS: During isoflurane-supplemented remifentanil-based anesthesia for patients undergoing cardiac surgery with preoperative LV ejection fraction greater than 50% (n = 20), we analyzed the changes of S' at each isoflurane dose increment (1.0, 1.5, and 2.0 minimum alveolar concentration [MAC]: T1, T2, and T3, respectively) with a fixed remifentanil dosage (1.0 μg/min/kg) by using transesophageal echocardiography.

    RESULTS: Mean S' values (95% confidence interval [CI]) at T1, T2, and T3 were 10.5 (8.8-12.2), 9.5 (8.3-10.8), and 8.4 (7.3-9.5) cm/s, respectively (P < 0.001 in multivariate analysis of variance test). Their mean differences at T1 vs. T2, T2 vs. T3, and T1 vs. T3 were -1.0 (-1.6, -0.3), -1.1 (-1.7, -0.6), and -2.1 (-3.1, -1.1) cm/s, respectively. Phenylephrine infusion rates were significantly increased (0.26, 0.22, and 0.47 μg/kg/min at T1, T2, and T3, respectively, P < 0.001).

    CONCLUSION: Isoflurane increments (1.0-2.0 MAC) dose-dependently reduced LV systolic long-axis performance during cardiac surgeries with a preserved preoperative systolic function.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links