Displaying all 6 publications

Abstract:
Sort:
  1. Behkami S, Zain SM, Gholami M, Bakirdere S
    Food Chem, 2017 Feb 15;217:438-444.
    PMID: 27664656 DOI: 10.1016/j.foodchem.2016.08.130
    The potential for the isotopic ratio analysis of cattle tail hair in determining the geographical origin of raw cow milk in Peninsular Malaysia had been investigated in this research using exploratory visualization. A significant positive correlation (p<0.0001) (n=54) was noticed between δ(13)C and δ(15)N in milk with that of hair which indicated that these matrices could be used in tracing the geographical origin of animal produce and tissues, and there is a possibility that hair could be used as a substitute in building the database for the geographical traceability of milk. It was also observed that both hair and milk isotopic ratio correlations exhibited separation between the northern and southern regions. The accuracy of using isotopic ratio in determining geographical discrimination had been clearly demonstrated when several commercial milk samples from the same regions under the study were correctly assigned to the appropriate geographical clusters.
  2. Gholami M, Behkami S, Zain SM, Bakirdere S
    Sci Rep, 2016 11 17;6:37186.
    PMID: 27853264 DOI: 10.1038/srep37186
    The objective of this work is to prepare a cost-effective, low reagent consumption and high performance polytetrafluoroethylene (PTFE) vessel that is capable to work in domestic microwave for digesting food and environmental samples. The designed vessel has a relatively thicker wall compared to that of commercial vessels. In this design, eight vessels are placed in an acrylonitrile butadiene styrene (ABS) holder to keep them safe and stable. This vessel needs only 2.0 mL of HNO3 and 1.0 mL H2O2 to digest 100 mg of biological sample. The performance of this design is then evaluated with an ICP-MS instrument in the analysis of the several NIST standard reference material of milk 1849a, rice flour 1568b, spinach leave 1570a and Peach Leaves 1547 in a domestic microwave oven with inverter technology. Outstanding agreement to (SRM) values are observed by using the suggested power to time microwave program, which simulates the reflux action occurring in this closed vessel. Taking into account the high cost of commercial microwave vessels and the volume of chemicals needed for various experiments (8-10 mL), this simple vessel is cost effective and suitable for digesting food and environmental samples.
  3. Behkami S, Zain SM, Gholami M, Khir MFA
    Food Chem, 2019 Oct 01;294:309-315.
    PMID: 31126468 DOI: 10.1016/j.foodchem.2019.05.060
    Spectra data from two instruments (UV-Vis/NIR and FT-NIR) consisting of three and one detectors, respectively, were employed in order to discriminate the geographical origin of milk as a way to detect adulteration. Initially, principal component analysis (PCA) was used to see if clusters of milk from different origins are formed. Separation between samples of different origins were not observed with PCA, hence, feed-forward multi-layer perceptron artificial neural network (MLP-ANN) models were designed. ANN models were developed by changing the number of input variables and the best models were chosen based on high values of generalized R-square and entropy R-square, as well as small values of root mean square error (RMSE), mean absolute deviation (Mean Abs. Dev), and -loglikelihood while considering 100% classification rate. Based on the results, whether the spectra data was collected from a single or three detector instrument the same clustering was observed based on geographical origin.
  4. Ghadiry M, Gholami M, Lai CK, Ahmad H, Chong WY
    PLoS One, 2016;11(4):e0153949.
    PMID: 27101247 DOI: 10.1371/journal.pone.0153949
    Generally, in a waveguide-based humidity sensors, increasing the relative humidity (RH) causes the cladding refractive index (RI) to increase due to cladding water absorption. However, if graphene oxide (GO) is used, a reverse phenomenon is seen due to a gap increase in graphene layers. In this paper, this interesting property is applied in order to fabricate differential humidity sensor using the difference between RI of reduced GO (rGO) and nano-anatase TiO2 in a chip. First, a new approach is proposed to prepare high quality nano-anatase TiO2 in solution form making the fabrication process simple and straightforward. Then, the resulted solutions (TiO2 and GO) are effortlessly drop casted and reduced on SU8 two channels waveguide and extensively examined against several humid conditions. Investigating the sensitivity and performance (response time) of the device, reveals a great linearity in a wide range of RH (35% to 98%) and a variation of more than 30 dB in transmitted optical power with a response time of only ~0.7 sec. The effect of coating concentration and UV treatment are studied on the performance and repeatability of the sensor and the attributed mechanisms explained. In addition, we report that using the current approach, devices with high sensitivity and very low response time of only 0.3 sec can be fabricated. Also, the proposed device was comprehensively compared with other state of the art proposed sensors in the literature and the results were promising. Since high sensitivity ~0.47dB/%RH and high dynamic performances were demonstrated, this sensor is a proper choice for biomedical applications.
  5. Ghadiry M, Gholami M, Kong LC, Yi CW, Ahmad H, Alias Y
    Sensors (Basel), 2015;16(1).
    PMID: 26729115 DOI: 10.3390/s16010039
    An on-chip optical humidity sensor using Nano-anatase TiO₂ coating is presented here. The coating material was prepared so that the result is in solution form, making the fabrication process quick and simple. Then, the solution was effortlessly spin-coated on an SU8 straight channel waveguide. Investigating the sensitivity and performance (response time) of the device revealed a great linearity in the wide range (35% to 98%) of relative humidity (RH). In addition, a variation of more than 14 dB in transmitted optical power was observed, with a response time of only ~0.7 s. The effect of coating concentration and UV treatment was examined on the performance and repeatability of the sensor. Interesting observations were found, and the attributed mechanisms were described. In addition, the proposed sensor was extensively compared with other state-of-the-art proposed counterparts from the literature and remarkable advantages were found. Since a high sensitivity of ~0.21 dB/%RH and high dynamic performances were demonstrated, this sensor is proposed for use in biomedical applications.
  6. Mahmoodi P, Rezayi M, Rasouli E, Avan A, Gholami M, Ghayour Mobarhan M, et al.
    J Nanobiotechnology, 2020 Jan 13;18(1):11.
    PMID: 31931815 DOI: 10.1186/s12951-020-0577-9
    BACKGROUND: In several years ago, infection with human papillomaviruses (HPVs), have been prevalent in the worlds especially HPV type 18, can lead to cervical cancer. Therefore, rapid, accurate, and early diagnosis of HPV for successful treatment is essential. The present study describes the development of a selective and sensitive electrochemical biosensor base on DNA, for early detection of HPV-18. For this purpose, a nanocomposite of reduced graphene oxide (rGO) and multiwalled carbon nanotubes (MWCNTs) were electrodeposited on a screen-printed carbon electrode (SPCE). Then, Au nanoparticles (AuNPs) were dropped on a modified SPCE. Subsequently, single strand DNA (ssDNA) probe was immobilized on the modified electrode. The link attached between AuNPs and probe ssDNA provided by L-cysteine via functionalizing AuNPs (Cys-AuNPs). The differential pulse voltammetry (DPV) assay was also used to electrochemical measurement. The measurement was based on the oxidation signals of anthraquninone-2-sulfonic acid monohydrate sodium salt (AQMS) before and after hybridization between the probe and target DNA.

    RESULTS: The calibration curve showed a linear range between 0.01 fM to 0.01 nM with a limit of detection 0.05 fM. The results showed that the optimum concentration for DNA probe was 5 µM. The good performance of the proposed biosensor was achieved through hybridization of DNA probe-modified SPCE with extracted DNA from clinical samples.

    CONCLUSIONS: According to the investigated results, this biosensor can be introduced as a proprietary, accurate, sensitive, and rapid diagnostic method of HPV 18 in the polymerase chain reaction (PCR) of real samples.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links