Displaying all 2 publications

Abstract:
Sort:
  1. Kul E, Abdulrahim R, Bayındır F, Matori KA, Gül P
    Dent Med Probl, 2021 5 14;58(2):187-191.
    PMID: 33982454 DOI: 10.17219/dmp/126745
    BACKGROUND: If a temporary restoration is in the esthetic area and needs to be worn for a long time, the color stability of temporary materials becomes an important factor.

    OBJECTIVES: The aim of this in vitro study was to evaluate the long-term effects of various staining solutions on the color stability of different temporary materials produced with the computer-aided design and computer-aided manufacturing (CAD/CAM) technology.

    MATERIAL AND METHODS: In the study, the following materials were used: VITA CAD-Temp® (group 1); Ceramill® Temp (group 2); and Telio® CAD (group 3). Forty disk-shaped specimens (10 mm in diameter, 2 mm in thickness) of each material (N = 120) were produced with a CAD/CAM system. Staining solutions - of tea (A), of coffee (B) and cola (C) - and distilled water (D, control) were used, and color was evaluated before and after storing the samples in the solutions. Measurements were taken with a spectrophotometer and the color parameters (L*, a*, b*, and ΔE) were calculated according to the Commission internationale de l'éclairage system (CIELab). The results were evaluated with the two-way analysis of variance (ANOVA) and Tukey's tests (α = 0.05).

    RESULTS: Clinically perceivable (ΔE00 > 0.8) and statistically significant (p < 0.001) color differences were detected in all specimens. The highest ΔE00 value was found in the Ceramill Temp specimens. In addition, the highest ΔE00 values were noted for the specimens stored in cola and the coffee solution for all groups. The lowest ΔE00 value was observed for the groups stored in the tea solution.

    CONCLUSIONS: Clinically perceivable color changes were observed in all the specimens kept in the solutions. Color changes were greater for cola and coffee as compared to tea.

  2. Kul E, Bayindir F, Gül P, Yesildal R, Matori KA
    PMID: 34104365
    Background: The aim of this study was to investigate whether boron nitride (BN) and BN-chromium (BN-Cr) coatings applied with the sputtering method would change the characteristics of hardness and discoloration of the ceramic veneer surface.

    Materials and Methods: In this experimental study, thirty disc-shaped cores (10 mm in diameter and 0.8 mm in thickness) were prepared. Three different ceramic systems, IPS Empress (E) (Ivoclar Vivadent, Schaan, Liechntenstein), IPS e.max Press (EP) (Ivoclar Vivadent, Schaan, Liechntenstein), and Turkom Cera (T) (Turcom-Ceramic SDN-BHD, Kuala Lumpur, Malaysia), were tested, each with n = 10. The specimens were divided into two subgroups (n = 5) according to the coating on the veneering ceramic: BN or BN-Cr. The Vickers hardness and color differences (ΔE) values were measured before and after coating. Surface analysis was performed with X-ray diffraction, X-ray photoelectron spectroscopy, and scanning electron microscopic. The Wilcoxon signed-rank test was performed to compare hardness values. The Kruskal-Wallis test was performed to compare ΔE values among all groups. The post hoc tests was used after Kruskal-Wallis, with level of statistical significance set at P ≤ 0.05.

    Results: BN-Cr coating statistically significantly increased the hardness of all types of ceramics (P < 0.05). BN coating did not change the hardness statistically significantly (P > 0.05). The mean ΔE values indicated clinically noticeable (over the limit of 3.7) color change in all groups except for the EP-BN and T-BN groups.

    Conclusion: Although BN-Cr coating in this thickness had a negative effect on color, it increased the hardness of the ceramics and could be useful in the palatal region.