Displaying all 5 publications

Abstract:
Sort:
  1. Chong PL, Singh AK, Kok SL
    PLoS One, 2019;14(6):e0218758.
    PMID: 31237903 DOI: 10.1371/journal.pone.0218758
    Electrical energy can be harvested from the living plants as a new potential renewable energy source. Characterization of the electrical signal is needed to enable an optimum energy harvesting setup condition. In the present paper, an investigation is conducted to analyze the characteristic of Aloe Barbadensis Miller (Aloe Vera) leaves in terms of electrical energy generation under specific experimental setups. The experimental results show that 1111.55uW electrical power can be harvested from the Aloe Vera with 24 pairs of electrodes and this energy is capable to be stored in a capacitor. This energy has a high potential to be used to power up a low power consumption device.
  2. Chong PL, Singh AK, Kok SL
    PLoS One, 2019;14(12):e0227153.
    PMID: 31881078 DOI: 10.1371/journal.pone.0227153
    It is well proven that electrical energy can be harvested from the living plants which can be used as a potential renewable energy source for powering wireless devices in remote areas where replacing or recharging the battery is a difficult task. Therefore, harvesting electrical energy from living plants in remote areas such as in farms or forest areas can be an ideal source of energy as these areas are rich with living plants. The present paper proposes a design of a power management circuit that can harness, store and manage the electrical energy which is harvested from the leaves of Aloe Barbadensis Miller (Aloe Vera) plants to trigger a transmitter load to power a remote sensor. The power management circuit consists of two sections namely; an energy storage system that acts as an energy storage reservoir to store the energy harvested from the plants as well as a voltage regulation system which is used to boost and manage the energy in accordance to a load operation. The experimental results show that the electrical energy harvested from the Aloe Vera under a specific setup condition can produce an output of 3.49 V and 1.1 mA. The harvested energy is being channeled to the power management circuit which can boost the voltage to 10.9 V under no load condition. The harvested energy from the plants boosted by the power management circuit can turn ON the transmitter automatically to activate a temperature and humidity sensor to measure the environmental stimuli periodically with a ton of 1.22 seconds and toff of 0.46 seconds. This proves that this new source of energy combined with a power management circuit can be employed for powering the wireless sensor network for application in the Internet of Things (IoT).
  3. Saw SH, Lee S, Roy F, Chong PL, Vengadeswaran V, Sidik AS, et al.
    Rev Sci Instrum, 2010 May;81(5):053505.
    PMID: 20515137 DOI: 10.1063/1.3429207
    The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L(0), and resistance r(0) to be obtained using lightly damped sinusoid equations given the bank capacitance C(0). However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained.
  4. Chong PL, Ismail D, Ng PK, Kong FY, Basir Khan MR, Thirugnanam S
    Sensors (Basel), 2024 Feb 10;24(4).
    PMID: 38400335 DOI: 10.3390/s24041177
    Electrical energy is often wasted through human negligence when people do not switch off electrical appliances such as lighting after leaving a place. Such a scenario often happens in a classroom when the last person leaves the class and forgets to switch off the electrical appliances. Such wastage may not be able to be afforded by schools that are limited financially. Therefore, this research proposed a simple and cost-effective system that can analyze whether there is or is not a human presence in the classroom by applying a counter to count the total number of people entering and leaving the classroom based on the sensing signals of a set of dual PIR sensors only and then correlating this to automatically turn on or off the electrical appliances mentioned. The total number of people identified in the classroom is also displayed on an LCD screen. A TRIZ approach is used to support the ideation of the system. The system can switch on several electrical output loads simultaneously when the presence of people is detected and switch them off when there are no people in the classroom. The proposed system can be expanded to be used in homes, offices, and buildings to prevent the high cost of electricity consumption caused by the negligence of people. This enables smarter control of electricity consumption.
  5. An X, Chong PL, Zohourkari I, Roy S, Merdji A, Linda Gnanasagaran C, et al.
    Proc Inst Mech Eng H, 2023 Aug;237(8):1008-1016.
    PMID: 37477395 DOI: 10.1177/09544119231187685
    The mechanical properties of tissue scaffolds are essential in providing stability for tissue repair and growth. Thus, the ability of scaffolds to withstand specific loads is crucial for scaffold design. Most research on scaffold pores focuses on grids with pore size and gradient structure, and many research models are based on scaffolding with vertically arranged holes. However, little attention is paid to the influence of the distribution of holes on the mechanical properties of the scaffold. To address this gap, this research investigates the effect of pore distribution on the mechanical properties of tissue scaffolds. The study involves four types of scaffold designs with regular and staggered pore arrangements and porosity ranging from 30% to 80%. Finite element analysis (FEA) was used to compare the mechanical properties of different scaffold designs, with von-Mises stress distribution maps generated for each scaffold. The results show that scaffolds with regular vertical holes exhibit a more uniform stress distribution and better mechanical performance than those with irregular holes. In contrast, the scaffold with a staggered arrangement of holes had a higher probability of stress concentration. The study emphasized the importance of balancing porosity and strength in scaffold design.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator ([email protected])

External Links